Climatic 

Standard 

Testy 

Level 

EN 60068-2-1 
Cold 
 

Ab 

-40 °C - 16 hours 

 Non-operating - TBD 

Ad 

-20 °C - 16 hours 

 Operating - TBD 

EN 60068-2-2 
Dry heat 

Bb 

+85 °C - 16 hours 

 Non-operating - TBD 

Bd 

+55 °C - 16 hours 

 Operating - TBD 

EN 60068-2-14 
Change of temperature 

Na 

-25 °C to +70 °C 

 Non-operating - TBD 

5 cycles of 2 hours 

Nb 

-20 °C to +55 °C 

 Operating - TBD 

3 °K/mn - 5 cycles of 2 hours 

EN 60068-2-30 
Damp heat 

Db 
Variante 2 

+25 °C à 55 °C 

 Operating - TBD 

2 cycles 

 
 
 
 

 

Содержание XSRACK

Страница 1: ...DOC_DEV_XSRACK_User guide_A XSRACK Switch SHDSL _________________ USER GUIDE _________________ ...

Страница 2: ...V_XSRACK_User guide_A The product family XSRACK is designed and manufactured by ETIC TELECOM 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL 33 0 4 76 04 20 05 E mail hotline etictelecom com web www etictelecom com ...

Страница 3: ...stances RoHS Directive 2011 65 UE Type of product SHDSL switch Models XSRACK 1260 The harmonized standards to which these products comply are Standard Title EN 61000 6 2 2006 Immunity EN61000 4 2 Electrostatic Discharge EN61000 4 3 RF Radiated Immunity EN61000 4 4 EFT Burst Immunity EN61000 4 5 Surge Immunity EN61000 4 6 RF Conducted Immunity EN61000 4 8 Power Frequency Magnetic Field Immunity EN ...

Страница 4: ......

Страница 5: ...and checking the line 17 6 1 Type of cable 17 6 2 Crosstalk interference 17 6 3 Shield earthing 17 6 4 Protecting the SHDSL switch from lightning 18 7 Connecting the XSRACK to the line 18 7 1 General precautions 18 7 2 Point to point connection using two three or four twisted pairs 18 PREPARING THE SETUP 19 1 Connecting a PC for configuration 19 1 1 Overview 19 1 2 First configuration 20 1 3 Chang...

Страница 6: ......

Страница 7: ...C Humidity 5 à 95 relative non condensing Power supply 110 à 230 VAC Internal dual power supply Consumption 30 W MTBF 150 600 Hazardous substances 2011 65 UE RoHS REACH SHDSL Number of ports 12 Modulation ITU T G 991 2 802 3ah 2BaseTL EFM Data rate 192 kb s to 15 2 Mb s Emission power Annex A 13 5 dBm 22 mW Annex B 14 5 dBm 28 mW Voltage of the emitted signal 6 to 8 V peak to peak on 135 Ohms Sign...

Страница 8: ...cast filtering Static routes RIP V2 QOS RFC 2474 2475 2597 2598 Differentiated services Traffic prioritization and bandwidth reservation Misc SNMP Supported MIBs RFC1213 MIB MIB 2 HDSL2 SHDSL LINE MIB HOST RESOURCES MIB IF MIB IP MIB BRIDGE MIB RSTP MIB Traps SNMP Date and time NTP client and server Configuration Web serveur Log Log with timestamp of the last 300 events Syslog Management Save and ...

Страница 9: ... shield coupling EN61000 4 6 RF conducted A SHDSL 10VAM 80 1khz 150khz to 80Mhz Power supply Ethernet EN61000 4 8 Magnetic A Enclosure 30 A M at 50hz 60hz EN61000 4 18 Damped wave A Power supply 0 5kV differential B 1kV common mode A Ethernet 1kV common mode B SHDSL 1kV common mode EMC Immunity ITU T K21 Norme Critère Port K44 Test N Lightning voltage special test protector A SHDSL 2 1 2a 5kV tran...

Страница 10: ... 20 C 16 hours Operating TBD EN 60068 2 2 Dry heat Bb 85 C 16 hours Non operating TBD Bd 55 C 16 hours Operating TBD EN 60068 2 14 Change of temperature Na 25 C to 70 C Non operating TBD 5 cycles of 2 hours Nb 20 C to 55 C Operating TBD 3 K mn 5 cycles of 2 hours EN 60068 2 30 Damp heat Db Variante 2 25 C à 55 C Operating TBD 2 cycles ...

Страница 11: ...ernet ports and has its own configuration and operation interface The slots are not hot swappable The XSRACK has two redundant power supplies Power supplies are often the most unreliable part of equipment The XSRACK is equipped with 2 230V 24V power supplies Each slot has 2 internal 24V power inputs If a power supply is faulty the SHDSL connections are maintained The LEDs on the front panel or the...

Страница 12: ...hus limiting the unwanted traffic on the SHDSL link VLAN The XSRACK features VLAN It is useful for example to separate the flows on the SHDSL link from those for the administration of the switch RSTP redundancy The XSRACK can fit into a complex topology including redundant links and devices from different manufacturers The Rapid Spanning Tree Protocol RSTP removes loops and prevent broadcast storm...

Страница 13: ..._User guide_A Page 13 INSTALLATION 1 Description 1 1 Dimensions 1 2 Front panel 1 3 Rear panel 280 mm 44 mm 6 mm 435 mm SHDSL screw block Ethernet LED indicators Slot 1 Slot 2 Slot 3 Power connector 110 230 V AC Push buttons Fan ...

Страница 14: ...ty 2 Tx Emission polarity 3 Rx Reception polarity 4 N C 5 N C 6 Rx Reception polarity 7 N C 8 N C 1 5 Push buttons Push button SLOT1 SLOT2 SLOT3 Pressing the PB LED Function During operation Flashing red Temporary return to the factory configuration IP address 192 168 0 128 The current configuration is not lost During power up Flashing red Return to the factory configuration The current configurat...

Страница 15: ...ff Steady green The unit is ready Slow blinking green The unit is busy Steady red Startup 30s Otherwise product failure Fast blinking red Firmware download in progress Ring Steady green The fail safe ring is established Steady red Fail safe ring failure Off Fail safe ring disabled SHDSL 1 SHDSL 2 SHDSL 3 SHDSL 4 1 to 4 green Off Port disable Blinking Connection in progress On Connection establishe...

Страница 16: ... or fixed using the mounting brackets provided When the mounting brackets are used it is possible to remove the self adhesive feet under the case 4 Cooling The XSRACK has a fan which ensures a low temperature difference between the outside and the inside This lowers the operating temperature of electronic components and thus improves MTBF However in the event of a fan failure the XSRACK continues ...

Страница 17: ...lectrical power cable Two power conductors can be used instead of a twisted pair to set an SHDSL connection However because the two wires are not twisted the ambient electrical noise may disturb the transmission Compared to the transmission over a twisted pair the maximum distance between two SHDSL switches is decreased 6 2 Crosstalk interference If the cable is made of several pairs a signal tran...

Страница 18: ...he earth 7 Connecting the XSRACK to the line 7 1 General precautions The SHDSL signal is not polarized the two wires of the twisted pair can be interchanged Check that the shield if any is properly earthed 7 2 Point to point connection using two three or four twisted pairs An aggregated link is a link between two SHDSL switches that uses two or three or four twisted pairs to multiply the total thr...

Страница 19: ... PC directly to the LAN interface of the each slot Subsequent changes can be made remotely Restoring the factory IP address The factory IP address 192 168 0 128 can be restored by pressing the push button on the rear of the product see page 13 Restricted access to the administration server If you do not have access to the administration server it is probably that access has been restricted for sec...

Страница 20: ...ch the web browser Launch the web browser and then enter the IP address of the slot 192 168 0 128 The Home page of the administration server is displayed Note Access to the administration server is not protected when configuring the slot for the first time 1 3 Changing the configuration later Thereafter the administration server of an XSRACK slot is accessible from the Ethernet interface or remote...

Страница 21: ... the product The product can be reached at the registered IP address Note If the IP address of the XSRACK slot is unknown the software tool EticFinder can be used This software detects all ETIC branded products on a local network After starting the software click on the Search button and when the product list is displayed double click on the product address to access the html server 3 Restoring th...

Страница 22: ...rname and password to access the administration server are lost you have to temporarily return to the factory settings access to the administration server is then free 5 Configuration steps To configure the product we advise to proceed as follows Set up the LAN interface Set up the SHDSL connections Set up VLAN Set up SNMP Set up QoS Set up the routing functions For detail about the configuration ...

Страница 23: ...link depending on the wire diameter and the distance These values are indicative in noise free environment Distance versus data rate through one pair Data rate 192Kb s 1 2Mb s 2 3Mb s 5 7 Mb s 6 7 Mb s 10 Mb s 12 Mb s 15 Mb s Distance Ø 0 9 mm 13 km 8 km 6 km 3 7 km 2 5 km 1 5 km 1 km 0 7 km Distance Ø 0 4 mm 7 km 4 km 3 km 2 km 1 3 km 0 9 km 0 6 km 0 4 km ...

Страница 24: ...13 Chemin du Vieux Chêne 38240 Meylan France Tel 33 0 4 76 04 20 00 contact etictelecom com www etictelecom com ...

Отзывы: