background image

Model SST–2

11/07 22804

(800) 234-4239

http://www.networketi.com

8 of 12

Environmental Technology, Inc.

remains. The ground fault condition will be persistent and will be remembered by 
the SST even if the unit loses power.

To clear the ground fault condition momentarily press the GFEP TEST/RESET 

switch on the SST.

Maintenance

The SST–2 does not require routine maintenance.
For technical help, questions or comments concerning this product or any 

Environmental Technology, Inc. prod ucts contact the Customer Service Department 
between 8:00am and 5:00pm ET at:

Voice: 

800.234.4239 (USA and Canada)  or  574.233.1202 (elsewhere)

Fax: 

888.234.4238 (USA and Canada)  or  574.233.2152 (elsewhere)

E-mail: [email protected]

Содержание SST-2

Страница 1: ...y Inc Environmental Technology Inc 1850 N Sheridan Street South Bend Indiana 46628 574 233 1202 or 800 234 4239 FAX 574 233 2152 or 888 234 4238 http www networketi com We Manage Heat Freeze Protectio...

Страница 2: ...Model SST 2 11 07 22804 800 234 4239 http www networketi com 2 of 12 Environmental Technology Inc...

Страница 3: ...ance contact Customer Service Of ce hours are 8 00 AM until 5 00 PM ET Voice 800 234 4239 USA and Canada or 574 233 1202 elsewhere Fax 888 234 4238 USA and Canada or 574 233 2152 elsewhere E mail help...

Страница 4: ...type Thermistor network Circuit type NEC Class 2 Lead Length Up to 2 000 610m using 12 AWG 2 wire jacketed cable Up to 500 152m using 18 AWG 2 wire jacketed cable Ground Fault Equipment Protection GFE...

Страница 5: ...o be installed on a xed at vertical surface The mounting anges accommodate 1 4 6mm fasteners The SST freeze protection thermostat nonmetallic enclosure is furnished with two 3 4 21mm conduit entries T...

Страница 6: ...Model SST 2 11 07 22804 800 234 4239 http www networketi com 6 of 12 Environmental Technology Inc Figure 2 SST 2 wiring See Appendix B Figure 3 SST 2 dimensions See Appendix B...

Страница 7: ...ich will remain lit whenever the SST senses supply power Next the SST 2 freeze protection thermostat performs a self test of the ground fault circuitry This is the same test automatically performed ap...

Страница 8: ...on momentarily press the GFEP TEST RESET switch on the SST Maintenance The SST 2 does not require routine maintenance For technical help questions or comments concerning this product or any Environmen...

Страница 9: ...9 http www networketi com 9 of 12 Environmental Technology Inc Appendix A SST 2 Dimensions 4 1 4 108mm 1 1 16 27mm Conduit Entry 3 8 10mm Temperature Sensor 1 7 16 37mm 20 6m Sensor Cable 3 16 5mm 7 7...

Страница 10: ...Model SST 2 11 07 22804 800 234 4239 http www networketi com 10 of 12 Environmental Technology Inc Appendix B SST 2 Wiring Diagram...

Страница 11: ...Model SST 2 22804 11 07 800 234 4239 http www networketi com 11 of 12 Environmental Technology Inc Appendix C SST 2 Wiring...

Страница 12: ...ed warranties of merchantability or tness for any particular purpose Environmental Technology Inc reserves the right to revise this publication and to make changes and improvements to the products des...

Отзывы: