2

SAFETY

Make all electrical connections in compliance 

with the National Electrical Code (NFPA 70) 

and the local electrical code.

ABNORMAL ODOR OR SMOKE

In the event of smoke, a burning odor or 

abnormal odor, immediately interrupt power 

to the unit by unplugging the unit or by turning 

off the circuit breaker protecting the unit

ELECTRICAL SHOCK / FIRE HAZARD

As a low voltage control the SNOW OWL has a 

maximum current load of 2 amps resistive for 

24 VAC and presents little hazard of electrical 

shock  or  fire.    The  SNOW  OWL  is  intended 

to control higher voltage / current heating 

circuits which can present such hazards so 

care must be taken when using the sensor for 

these applications. This product is intended for 

residential or light commercial applications.

Any installation involving electric heaters must 

be grounded to earth to protect against shock 

and fire hazard.  Use a suitably sized ground 

fault detection and interruption system to 

reduce shock and fire hazard and to protect 

SPECIFICATIONS

Dimensions
Input Power
Ouput
Hold On Time
Operating Temperature
Temperature Set Point
Storage Temperature

Height: 3.75”  Diameter: 1.75”
24 V AC 50/60 Hz or 24V DC or 24V full wave rectified AC/ Pulsed DC 0.2A max
Relay Contacts: 2 Amps max, 30 V
Zero hold on time
-40

º

C to +85

º

C (-40

º

F to +185

º

F)

38

º

F

-40

º

C to +85

º

C (-40

º

F to +185

º

F)

 

equipment.  Wiring to heating elements must 

be installed in accordance with the National 

Electrical Code (NEC) requirements and all 

other local and applicable electrical codes 

and any third party standards.  Follow the 

installation instructions contained in this 

manual and those provided by the heater 

manufacturer.

Use a GFEP (Ground Fault Equipment 

Protection) circuit breaker on each branch 

circuit connected to the ice melting system.  

Clearly label each circuit breaker with its 

function.  This is vitally important when there is 

more than a single point of disconnect.  Size 

the circuit breaker in accordance with the size 

of the maximum expected load.  

Make certain that the heater shield is properly 

grounded.  Failure to do so may result in 

electrical shock, damage to equipment or fire.

The Snow Owl performs an internal self test 

when the power is first turned on.  During the 

first  10  seconds  of  power  up  the  sensor  will 

turn on its output for a short time and engage 

any contactor that is connected to it. 

For this 

reason care should be taken to ensure that 

heater power is either connected properly or 

that it is turned off/ disconnected before 

powering up the sensor.

Following installation and prior to beginning 

system operation refer to and perform the 

post-installation tests described in this 

manual.

THEORY OF OPERATION

The SNOW OWL sensor monitors atmospheric 

conditions to determine when a snow/ freezing 

rain event occurs and responds by providing 

a grounded output to the control circuit or 

contactor which in turn will enable the heating 

system. 

It  does  this  by  using  the  snowflake  shaped 

moisture sensor on the top cap to melt the 

snow/ ice that lands on it and then detects the 

resulting water using a low voltage current.  

The detection of water alone will not provide 

an output but is used in combination with a 

temperature reading below 38

0

 F. An Internal 

processor looks for this combination or 

moisture and temperature and triggers the 

output only when both conditions are present.

This allows the SNOW OWL to trigger a heat 

cycle only when it is needed.  Once the SNOW 

OWL has triggered it will remain on until 

one or both of the stimuli is removed, and it 

determines that the stimuli remains missing 

for the next 4 minutes.