INSTALLATION MANUAL
23033 Rev. A 04/10 http://www.networketi.com Environmental Technology, Inc. Page 3 of 4
Step 10: Insert red wire into Pin 2 of terminal.
Insert black wire into Pin 1 of terminal.
Step 11: Connect air line tubing to solenoid barbed
fitting.
Step 12: Reinstall cover.
Step 13: Reconnect power cord and turn on unit.
The new DC brushless pump is polarized. Failing to wire as
shown will damage the pump motor and can cause additional
damage to the dehydrator.
(1)
(3)
(4)
(2)
Front of machine
Pins 1 and 3 are Ground.
Pins 2 and 4 are Positive.
(+) (GR) (+) (GR)
White dot on circuit board
Connect Red wire to Pin 2;
Connect Black wire to Pin 1.
Detail for Step 10
Terminal Block TB1
TB1