ETI Solid State Lighting 53508101 Скачать руководство пользователя страница 3

 WARNING: 

To reduce the risk of fire, electric shock, or injury to persons: Use only insulated staples or plastic ties to secure cords. • Route and secure cords so that they will not be 

pinched or damaged when the cabinet is pushed to the wall. • Do not use for recessed installation in ceilings or soffits.  • CAUTION: The National Electrical Code (NEC) does not permit 

cords to be concealed where damage to insulation may go unnoticed. To prevent fire danger, do not run cord behind walls, ceilings, soffits, or cabinets where it may be inaccessible 

for examination. Cords should be visually examined periodically and immediately replaced when any damage is noted.  • Maximum number of units to be interconnected: 53508101 

(18 in. under cabinet light): maximum 30 units.  Maximum distance between connected units is 14.5 in.  • To prevent electric shock, match wide blade of the plug to the wide slot and 

fully insert into the electrical outlet.

NOTICE: 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device 

must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference

in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful

interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio

or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which

the receiver is connected, and consult the dealer or an experienced radio/TV. 
• Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. • Not for emergency lighting.
See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.

Questions, problems, missing parts? Call ETiSSL Customer Service 8 a.m. - 5 p.m., CST, Monday - Friday

1-855-ETI-SSLI (1-855-384-7754) www.ETiSSL.com

LInkIng feature

WARNING: RISK OF ELECTRIC SHOCK. Disconnect power to the under cabinet light before linking 

additional under cabinet lights.

Multiple light fixtures can be connected, up to a maximum of 300 total watts.

Only the first light fixture needs to be plugged into an electrical outlet or directly wired.

Provide power to the fixtures only after all linking connections have been made.

Connect each additional fixture using either the linking cable or end-to-end connector.  Remove the 

end cover and insert either the end to-end connector or linking cable into the receptacle in the end 

of each under cabinet light fixture. When using the linking cable, the maximum distance between two 

light fixtures is 14.5 in. using the linking cable provided.

Use wire clips to affix the linking cable to the underside of the cabinet, if desired.

I

J

A

A

A

A

BeaM aDjustMent feature

Rotate the tabs on each end of the light fixture to adjust the light angle to the desired position.

NOTE:

 A minimum of 60% of the total lumen output is achieved in an adjustable beam angle 

of 22.5°.

oPeratIng the fIxture

Use the toggle switch on the fixture to control the light.

If the under cabinet lights are installed on a dimming circuit, use the dimmer switch to adjust the 

brightness.

NOTE:

 Color of the light warms when dimmed starting at the selected Color Temperature (CCT) 

2700K/3000K/4000K/Grow Mode.

Toggle Switch

Model no.

Part no.

Maximum connected units

53508101

 GL-18IN-500LM-8-CP3-SV-TD 

30

La versión española está en el  

sitio web www.ETiSSL.com.

Содержание 53508101

Страница 1: ... the knock out holes on the back plate If installing the MagnaMount mounting plate Punch out the matching knock out hole on the MagnaMount mounting plate Insert the strain relief clamp into the knock out hole from the outside in on the back plate Use and Care Guide Adjustable LED Under Cabinet Light with Grow Mode Model 53508101 Part GL 18IN 500LM 8 CP3 SV TD Certification 53508101 A 1 2 3 4 5a Su...

Страница 2: ...sion Mounting Installing contractor is responsible for determining best installation method for desired location Insert the V clips into the holes at each end of the fixture 6c Secure the V clips to the hooks installed in the ceiling 7c A L A L End Cap H Remove the end cap on the Power In end of the fixture and connect the linking cable to the fixture and attach the plug connector to the linking c...

Страница 3: ...n the equipment and the receiver connect the equipment into an outlet on a circuit different from that to which the receiver is connected and consult the dealer or an experienced radio TV Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Not for emergency lighting See website for Warranty Troubleshooting...

Страница 4: ...ne des débouchures sur la plaque de fond Si vous posez la plaque de montage MagnaMountMC Défoncez la débouchure correspondante sur la plaque de montage MagnaMountMC Insérez le détendeur dans la débouchure par l extérieur de la plaque de fond GUIDE D UTILISATION ET D ENTRETIEN LAMPE DEL SOUS ARMOIRE AJUSTABLE AVEC MODE DE SERRE N modèle 53508101 N de pièce GL 18IN 500LM 8 CP3 SV TD N de certificati...

Страница 5: ...n revient à l installateur d établir la meilleure méthode d installation pour l endroit voulu Posez les pinces en V dans les trous à chaque extrémité de la lampe 6c Attachez les pinces en V sur les crochets installés dans le plafond 7c A L A L Capuchon d embout H Enlevez le capuchon sur l embout Power In de la lampe et connectez le câble d interconnexion à la lampe puis le connecteur à fiche dans ...

Страница 6: ...nne réceptrice Augmenter la distance entre le dispositif et le poste récepteur Brancher l équipement dans une prise de courant sur un circuit autre que celui sur lequel le récepteur est branché Demander conseil auprès du marchand ou d un technicien en radio télé Tout changement ou toute modification non expressément approuvée par la partie responsable de la conformité peut rendre nulle l autorisat...

Отзывы: