background image

1.

   Close the jaws of the instrument by squeezing the closing trigger 

until a click is heard. The audible click indicates that the closing 
trigger and the jaws are locked.

2.

  To open the jaws, squeeze the closing trigger, and then  

simultaneously push the anvil release button on the side of the  
device. Maintain pressure on the anvil release button and slowly  
release the closing trigger.

Opening and Closing the Jaws

Articulation

Four Ways to Articulate

Ensure that the jaws are in the open position.

1.  

Pull back and hold the articulation fin to activate the articulation joint.

2.  

Apply lateral pressure to the jaws to articulate the device.

3.  

Release articulation fin to lock jaws into articulated position.

4. 

Clamp, staple, cut, return, release.

1.

  Against the body wall

3.

  Against a grasper

2.

  Against tissue in the body

4.

 Hand assisted

Содержание ECHELON FLEX Powered

Страница 1: ...In Servicing Guide ECHELON FLEX Powered and Powered Plus Staplers...

Страница 2: ...se Button Knife Reverse Switch Manual Override Articulation Joint Shaft Articulation Fin and Rotating Knob Reload Alignment Slot Firing Trigger Closing Trigger Red Firing Trigger Lock Knife Blade Indi...

Страница 3: ...ining cap by lifting it straight up and discard Loading the Device 3 Ensure that the staple retaining cap is present Insert the reload by sliding it against the bottom of the reload jaw until the stap...

Страница 4: ...re on the anvil release button and slowly release the closing trigger Opening and Closing the Jaws Articulation Four Ways to Articulate Ensure that the jaws are in the open position 1 Pull back and ho...

Страница 5: ...ng the jaws in place for 15 seconds after closing and prior to firing may result in better compression and staple formation 3 Pull back the red firing trigger lock 4 Pull the exposed trigger to fire m...

Страница 6: ...reverse switch forward 2 Battery Remove and re install the battery to check that it is securely installed and that the device has power 3 Reverse See Step 1 4 Override If the knife does not return use...

Страница 7: ...if the reverse switch does not return the knife blade Reloading the Device 1 Push upward toward the anvil to unsnap the reload from the reload jaw 2 Prior to reloading the instrument hold the instrume...

Страница 8: ...reen D Pro 3 10 bleach 70 isopropyl alcohol prepared according to the manufacturer s instructions Thoroughly scrub areas that contain crevices Thoroughly wipe off detergent with lukewarm tap water DO...

Страница 9: ...For complete product details see Instructions for Use 2014 Ethicon US LLC All rights reserved 019927 140814...

Отзывы: