EX26484 Managed PoE Switch Installation Guide 

 

Copyright 2022 EtherWAN Systems, Inc.

  

  Page 2 

 

All Rights Reserved 

EX26484 v2  

1/10/2022 

When logging into the management Web GUI 

for the first time, the system will ask you to 

change the login password immediately. To 

change the password, please click the 

“admin” hyperlink as shown: 

 

Press the scroll-down menu and set the 

“Change Password” field to “Yes”.  

 

Type in the new password twice and press 

the “Save” button.  

 

 

The new password must meet the following 

complexity requirements: 

Minimum 8 characters and maximum 35 

characters in password length without leading or 

trailing blanks. 

The password must contain characters from the 

following categories: 

1. Uppercase English letters, (A to Z) 

2. Lowercase English letters, (a to z) 

3. Numbers, (0 to 9) 

4. Non-alphanumeric characters (e.g. @, #, !) 

G.

 

Go to 

Configuration->System->IP

 and 

perform one of these steps: 

If your network uses a DHCP server, check 

Enable under 

DHCPv4

If your network uses static IP addresses, 
enter the switch’s 

IP address

 under 

IPv4

H.

 

Click 

Save

 to save the settings to the running 

configuration. If current settings are not 

saved as startup config, all current settings 

will be lost when the switch is rebooted. To 

save the settings to the startup configuration, 

go to 

Maintenance->Configuration->Save 

startup-config

 and click 

Save Configuration

 

Factory Reset 

To reset the device back to factory default 

settings, connect port 1 and 2 with an Ethernet 

cable within 1 minute of the device booting up.  
In the first minute after boot-up, packets will be 

transmitted from port 1. If the packets are 

received by port 2, the switch will be reset to 

default settings. 

 

Console Configuration 

 

Connect to the switch console using a RJ45 

to DB9 console cable (RJ45 pinout shown 

below) to the RJ45 console port of the switch 

and to the serial port of the PC running a 

terminal emulation application (such as 

Putty). 

 

Configuration settings of the emulator: Baud 

rate: 115,200bps, Data bits: 8, Parity: none, 

Stop bit: 1, Flow control: none. 

 

Front Panel LEDs 

LED 

Color 

Status 

PoE 

Orange 

O

N = Power Device (PD) is connected.

 

RJ45

 

(per port)

 

Green 

ON = valid network connection.

 

Flashing = port is sending or receiving data. 

SFP+

 

(per port)

 

Green 

ON = fiber connection. 

Flashing = port is sending or receiving data. 

 