![Etherma ET-71 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/etherma/et-71/et-71_manual_2432632029.webp)
27
EN
27
EN
Control functions
The thermostat can regulate the tempera-
ture in three different ways. This enables
the comfort temperature and any flooring
temperature requirements to be combined.
How the settings are adjusted is descri-
bed on the next page
.
Floor thermostat
(F) - A sensor in the floor
measures the temperature and then regu-
lates the heating accordingly. This is the
factory setting.
Room thermostat
(R) - The thermostat
has built-in sensors for measuring the
room’s temperature and controlling the
heating.
Room and floor thermostat
(
R&F
)
- The
built-in sensor regulates the room tem-
perature and the sensor in the floor func-
tions as a floor temperature limiter. The
limitation can be set to between 25°C
and 45°C. The factory setting is 35 °C.
Important
In rooms with large windows that are ex-
posed to solar insolation, we recommend
the Room and floor thermostat
function.
In rooms with wooden flooring, the
Room and floor thermostat
function
must always be used.