ETG LTM-1000 Скачать руководство пользователя страница 2

 

 

Contents 

 
1

 

Equipment description 

 
2

 

Loop Detector functional specification 

 
3

 

Equipment electrical and Physical specification 

 
 

Legislative and Regulatory Compliance 

RoHS - EU Directive 2002/95/EC per Category 9 / Annex IA – Exempt until 2010 

Electrical Power surge 1kV - rise time 1.2sec/hold 50 secs 

CE / Ctick compliant IEC1000-4-5/ EN61000-4-5 
 
Note: This is not a laboratory test instrument.  This is a purpose designed field test instrument that 
facilitates evaluation of  in-pavement loop characteristics including; inductance, DC Resistance, tuned 
frequency, ‘Q’ and insulation integrity.  
 
 

! ! ! ! !    W A R N I N G         *****         C A U T I O N    ! ! ! !  

 
EXTREME CARE REQUIRED WHEN using the insulation breakdown test function.  This is a 
controlled voltage ‘Megger’ test where typically 500V is applied to the output pins for a preset period 
(100milliseconds) while the microcomputer monitors the resistance to earth.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DISCLAIMER 

Excel Technology Group Pty Ltd reserves the right to make changes to the technology described in this document without notice 
and advises its clients to obtain the latest version of the relevant information prior to placing an order.  Excel Technology Group 
Pty Ltd warrants its products to the specification detailed herein in accordance with standard conditions of sale, client 
specification, and conditions imposed through government legislation. 
 
Testing and product control techniques are utilised to the extent that Excel Technology Group Pty Ltd deems necessary to 
support the relevant specification and warranty.  Excel Technology Group Pty Ltd acknowledges the proprietary information 
provided by Third Party component suppliers however, Excel Technology Group Pty Ltd assumes No Responsibility for the use 
of any other circuit or device other than the circuitry embodied on Excel Technology Group Pty Ltd numbered engineering 
drawings and on Excel Technology Group Pty Ltd circuit cards as identified according to the requirements of the Circuit Layouts 
Act 1989 (Australia).  Excel Technology Group Pty Ltd is not liable for any damage consequential or otherwise related to the use 
of this equipment. 
 
Excel Technology Group Pty Ltd grants the user/client rights to reproduce any of the documents contained herein but not subject 
to conditions of ‘Non-Disclosure’, providing such reproduction is conducted with no alteration to any material written, drawn or 
otherwise reproduced and/or contained in this document. 

Содержание LTM-1000

Страница 1: ...ETG In Pavement Loop Tester Model Number Original Revision 1 0 March 2007 man__a doc This revision 27 07 2012 Rev F...

Страница 2: ...cing an order Excel Technology Group Pty Ltd warrants its products to the specification detailed herein in accordance with standard conditions of sale client specification and conditions imposed throu...

Страница 3: ...ngle 9V D cell The device will automatically switch OFF after a preset period to enable longer battery life WHEN disconnected from a loop Activating the ON button wakes up the internal microprocessor...

Страница 4: ...of the loop Typically 15 140Khz Inductance Is the inductance value of the loop Typically 40 700 MicroHenries Resistance Is the DC resistance of the loop Typically 1 3ohms Q Is the performance value o...

Страница 5: ...n Factory Test Certified at the following levels of resistance 10MegOhm 5 50MegOhm 5 10 and 200MegOhm 10 A resistor network composed of 0 5watt 10MegOhm resistors is used for this test It is acknowled...

Страница 6: ...of road safe where the test is being performed as it is not possible to observe the instrument AND observe approaching vehicles simultaneously This specific nature of this requirement may vary accordi...

Страница 7: ...ever this variation is not affected by C C only affects the absolute value of What does all this mean Changing the resonant frequency point for a fixed inductor a loop requires changing the capacitanc...

Страница 8: ...maller vehicle and the accuracy achievable by the vehicle detector in measuring the vehicle length The following example indicates how low Q effects vehicle length measurement and how adjustments in t...

Страница 9: ...nce and then computes the related values of resistance inductance and Q within the resonance equation The tester has a high voltage generation circuit which produces 500Vs for approximately 1 second i...

Страница 10: ...ohmmax DC100mA Mate enlock Current rating 3amp per pin Contact Resistance 30Mohmmax DC100mA PCB Modular Terminal Phoenix style 10Amp Rated Voltage 300VAC IDC Style Connectors Withstanding Voltage 500v...

Страница 11: ...inductance based on frequency and a preset capacitance reference The LTM1000 generates a 500V DC pulse for typically 50 milliseconds to determine insulation quality The LTM1000 incorporates a highly...

Страница 12: ...Statement The LTM1000 In pavement Loop Tester Serial Number ET 0708 029 was tested in relation to preset calibrated test loops and in accordance with the manufacturers product specification LT_IND50...

Страница 13: ...140Khz 1 The loop tester referred to as LT1000 has been constructed such that generated electromagnetic disturbances shall not interfere with other equipment A report of compliance in relation to IEC...