Страница 1: ...aternit hot water solutions by CHRIMSIEN EXTERNAL GAS HOT WATER UNIT INSTALLATION AND OPERATING INSTRUCTIONS MODELS G16 G20 G26 FOR ADVICE REPAIRS AND FAST SERVICE 1300 367 565 20501072 K ...
Страница 2: ...Water Connection 7 Hot Water Connection 8 Electrical Requirements 8 Remote Controls 9 Remote Controls Wiring Diagram 10 Main Remote Control 11 Shower Remote Control 12 Mounting Remote Controls 13 14 User Instructions 15 17 Care of THE ETERNITY Hot Water Unit 18 Hints for Using THE ETERNITY Unit 19 23 Fault Monitor 24 Warranty Conditions 25 ...
Страница 3: ...e Code Part 4 Hot Water Supply Systems 4 The Australian Gas Association installation code AS5601 for gas burning appliances and equipment 5 Any other statutory regulation that may apply 6 A notice of intention to install shall be lodged with the relevant Municipal Authority and local Gas Authority prior to installation INSTALLATION MUST BE CARRIED OUT ONLY BY AN AUTHORISED AND APPROPRIATELY LICENS...
Страница 4: ...PPLY INLET RP3 4 20 PRESSURE RELIEF VALVE 330 CABLE ENTRY POINT HOT WATER OUTLET RP3 4 20 10111 YAN pi Cr 25 WATER INLET FILTER GAS SUPPLY INLET RP3 4 20 COLD WATER INLET RP3 4 20 PRESSURE RELIEF VALVE 330 COLD WATER INLET RP1 2 15 12 165 15 Model 16 20 Model 26 DIMENSIONS CONNECTIONS 2 ...
Страница 5: ...ER CASE 5 HOT WATER OUTLET 6 COLD WATER INLET 7 GAS SUPPLY INLET 8 HEAT EXCHANGER NOS PARTS DESCRIPTION 1 FLUE OUTLET 2 GAS VALVE 3 CIRCUIT BOARD 4 BURNER CASE 5 HOT WATER OUTLET 6 COLD WATER INLET 7 GAS SUPPLY INLET 8 HEAT EXCHANGER 9 WATER VOLUME PROPORTIONAL VALVE 0 0 Model 16 20 Model 26 0 0 0 0 EXPLODED DIAGRAM 2 3 ...
Страница 6: ... mm Input voltage single phase 50Hz 240V Maximum output current MODEL 16 20 26 Amp 0 37 0 45 0 47 SAIG Approval certificate no MODEL 16 20 GSCS 20021 26 GSCS 20021 Inlet gas connection male thread 18mm Cold water connection male thread MODEL 16 20 13mm 26 18mm Hot water connection male thread MODEL 16 20 13mm 26 18mm Relief valve pressure setting 14001cPa Weight dry MODEL 16 20 16kg 26 17kg 1 2 DA...
Страница 7: ...DOOR USE Refer AS5601 for clearance details for flue terminal In addition ensure that the appliance installation position permits easy access for maintenance and operation For further infomation please refer to the Gas Fitting Regulations 1 7 POSITION FOR INSTALLATION The heater must be installed by using a fixing method sufficient to hold the weight of the unit see the technical sheet for dimensi...
Страница 8: ...KG per hour capacity 5 Before connecting the appliance to the gas service purge any debris or air from the gas service Venting of purged gas shall be an area free of sources of ignition Close the isolating gas cock prior to connection of the appliance 6 After connection check all joints for leaks with an approved leak tester Refer to AS5601 Installation Code for pipe sizing details For your assist...
Страница 9: ...e cold water supply should be sized according to local BY LAWS for water supply ISOLATING GATE VALVE or BALL VALVE A GATE VALVE or BALL VALVE must be used on the cold water inlet to the water heater THIS REQUIREMENT IS AN AUSTRALIA WIDE REQUIREMENT UNDER THE NATIONAL PLUMBING CODE IF THE ABOVE INSTRUCTION IS NOT CARRIED OUT ALL WARRANTIES ON THE UNIT WILL BE VOIDED STOP TAPS OR COMBINATION STOP TA...
Страница 10: ...UTLET OF THE WATER HEATER 2 4 DO NOT FIT ANY OBSTRUCTION TO THE PRESSURE RELIEF LOCATED ON THE HOT WATER OUTLET CONNECTION 2 5 After purging the air from the system using the hot water supply taps remove the water inlet strainer located on the cold water supply inlet connection Remove any debris from the filter and replace When replacing the filter do not over tighten the O ring seal ELECTRICAL RE...
Страница 11: ... for disconnection and removal 4 4 CONNECTION OF WIRING TO THE ETERNITY Remove the front cover from the unit Install the wiring to the ETERNITY 16 20 26 main unit using conduit or by concealing the wires in the wall cavity Install the wiring into the cabinet through the wiring access adjacent to the power cable see the Technical Sheet 4 5 Using the cable clamps provided on the plate adjacent to th...
Страница 12: ...FREEZE HEATER WIRING DIAGRAM OF PCB TURN OFF POWER SUPPLY TO HOT WATER UNIT AND REMOVE PLUG FROM POWER OUTLET BEFORE REMOVING FRONT COVER OF HOT WATER UNIT WIRING FROM MAIN UNIT TO MAIN SHOWER SUB REMOTE CONTROLS MAIN CONTROL SHOWER CONTROL 240volt POWER SUPPLY SUB CONTROL ENSUITE 1 REMOTE CONTROLS WIRING DIAGRAM 10 ...
Страница 13: ...ICE ON 2 TEMPERATURE CONTROL ADJUSTS TEMPERATURE BETWEEN 37 C TO 75 C 3 TRANSFER INDICATOR INDICATES THIS CONTROL HAS PRIORITY GREEN CAN ADJUST TEMPERATURE ONLY WHEN THE INDICATOR IS ILLUMINATED 4 ON INDICATOR GREEN INDICATES POWER IS ON TO SYSTEM 5 ON OFF SWITCH POWER SWITCH TO OPERATE THIS CONTROL 6 COMBUSTION LAMP RED INDICATES A HOT WATER TAP IS BEING OPERATED 7 ALARM LAMP RED FLASHES IN ABNOR...
Страница 14: ...WITCH GREEN 3 A TRANSFER INDICATOR GREEN 3 B TRANSFER INDICATOR GREEN T LAMP 4 ON INDICATOR GREEN 5 ON OFF SWITCH 6 COMBUSTION LAMP RED 7 ALARM LAMP RED FUNCTION INDICATES TEMPERATURE TIME ERROR CODE WHEN SAFETY DEVICE ON ADJUSTS TEMPERATURE BETWEEN 37 C TO 48 C PUSHES TO SET PRIORITY TO THIS CONTROL INDICATES THIS CONTROL HAS PRIORITY INDICATES THIS CONTROL HAS PRIORITY INDICATES POWER IS ON TO S...
Страница 15: ...LOWING PARTS PROVIDED MAIN CONTROLS MODEL CMR 154 j V 01 _____ 2PCS 2PCS REMOTE CONTROLS WOOD SCREW CURL PLUG WIRING SHOWER SUB CONTROLS MODEL YST 84 YST 84S 1111 11 11A cr 2PCS 04 2PCS 41111 2PCS REMOTE CONTROLS WOOD SCREW CURL PLUG CONNECTOR C 1D 4 __ _____ WIRING CABLE CLAMP MOUNTING REMOTE CONTROLS 13 ...
Страница 16: ...WALL WITH WOOD SCREWS PROVIDED USING ANY TWO HOLES OUT OF THE SIX HOLES PROVIDED TO THE BRACKET 2 FASTEN WIRING TO THE TERMINAL BLOCK 3 FIX THE REMOTE CONTROLS TO THE BRACKET CATCHING THREE NAILS OF THE BRACKET THROUGH NOTCH AND THEN SLIDING FROM ABOVE FIRM UNTIL IT CATCHES THE NOTCH IN THE BRACKET AND CLICKS B DIRECT MOUNTING REFER THE DIAGRAM BELOW 1 REMOVE THE FRONT COVER OF THE CONTROLS USING ...
Страница 17: ...ercial units 75 C OPERATION OF MAIN REMOTE CONTROLS PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS APPLIANCE 1 TURN ON THE ON OFF SWITCH REFER PG 11 OF THIS MANUAL 2 THE TEMPERATURE DISPLAY WILL ILLUMINATE AT 42 C 3 THE T AND ON INDICATORS WILL ILLUMINATE 4 SELECT HOT WATER TEMPERATURE BY PRESSING UP DOWN BUTTONS ON THE CONTROLS 5 TURN ON A HOT WATER TAP COMBUSTION INDICATOR WILL ILLUM...
Страница 18: ...OLS See diagram 1 below 2 Press the TRANSFER BUTTON and the TRANSFER light will illuminate and the TEMPERATURE DISPLAY will have 42 C displayed Please refer to page 12 of this handbook See diagram 2 below 3 Using the UP DOWN BUTTONS select the temperature required See diagram 3 below 4 When you have finished using the hot water supply press the TRANSFER BUTTON to return the controls back to the MA...
Страница 19: ...t or cold water taps are used the temperature will be maintained THE TEMPERATURE WILL INCREASE BY 1 C WITH EACH PRESS OF THE UP DOWN BUTTONS THE TEMPERATURE CAN BE ADJUSTED CONTINUOUSLY BY KEEPING THE BUTTON PRESSED OVER 50 C UP TO 75 C THE TEMPERATURE IS CONTROLLED BY 5 C NOTCH PLEASE NOTE ABOVE 50 C SCALDING CAN OCCUR WITHIN SECONDS 4 The MAIN REMOTE CONTROL is left switched on at all times for ...
Страница 20: ...ANY GAS SMELL COMES FROM THE UNIT DO NOT USE NAKED FLAMES TO TEST FOR GAS LEAKS TURN OFF THE GAS SUPPLY AND POWER AND CONTACT YOUR GAS SUPPLY COMPANY 6 IF A POWER FAILURE OCCURS THE REMOTE CONTROLS WILL NOT FUNCTION AND THE CHOFU UNIT WILL NOT SUPPLY HOT WATER UNTIL POWER IS RESTORED WHEN POWER IS RESTORED THE REMOTE CONTROLS WILL RESET AT 42 C AS A SAFE TEMPERATURE PLEASE NOTE 4 5 CARE OF THE ETE...
Страница 21: ... m A Gas Safely 8 Certified As 4552 SA1 Global INPUT M1 11 OUTPUT kW M1 125 27 8 INPUT M 1 11 OUTPUT kW h 160 365 INPUT M 1 11 OUTPUT kW M1 200 94 4 TEST POINT PRESSURE HIGH kPa TEST POINT PRESSURE LOW kPa 0 40 G103 TEST POINT PRESSURE HIGH kPa TEST POINT PRESSURE LOW kPa 0 56 0 103 TEST POINT PRESSURE HIGH kPa TEST POINT PRESSURE LOW kPa 0 68 0 118 GAS INJECTORS rnrn 135 1 65 GAS INJECTORS 1 r11 ...
Страница 22: ...e any inflammable items such as gasoline or benzene nor use them around the unit Take special care O L Warning Freeze Prevention This unit comes equipped with electric heaters that discourage the water heater from frerzing To enable this freeze prevention system to operate there must be an electrical power supply connected to the unit The freeze prevention devices will not operate if the electrica...
Страница 23: ... there is an emergency such as earthquake or fire apply following procedure 1 Close the hot water outlet 2 Close the gas valve and the main water valve 3 Turn off the main power However in case of gas leakage first close the gas valve then wait for the leaked gas to disperse then turn off the main power supply 4 Contact the dealer from whom you bought the unit Caution 21 ...
Страница 24: ...power point DO NOT PULL POWER CORD May generate heat and cause fire DO NOT USE POWER CORD BUNDLED May generate heat and cause fire Do not turn off the power plug by pulling the cord It may generate heat by wire breakage then cause fire If the power supply cord is damaged it should be replaced by a cord available from ETERNITY Agents Never use power cord in a bundled condition It will cause heat ge...
Страница 25: ...t put water on the remote controls When installed near to TV or radio it may cause It will cause failure picture disturbance or sound disturbance Install away from those appliances Instant overflow voltage caused by lightn ng can Make sure to secure good enough space around damage the electronic parts Therefore to n off the unit to ensure space necessary for checking the main power when you have t...
Страница 26: ...UAL FLAME SAFETY CALL SERVICE CENTRE DEVICE 32 THERMISTOR WIRE BREAKAGE CALL SERVICE CENTRE 61 COMBUSTION FAN FAILURE CALL SERVICE CENTRE 740 COMMUNICATION FAILURE TURN OFF POWER AND TURN 750 BETWEEN REMOTE CONTROLS ON AGAIN 760 PCB PLEASE NOTE REPLACENT POWER CODE FOR THIS APPLIANCE CAN BE OBTAINED FROM THE ETERNITY SERVICE DEPARTMENT TELEPHONE 1300367565 PLEASE NOTE ONLY AUTHORISED PERSONS ARE T...
Страница 27: ... mg litre or ppm Up to 300 mg litre or ppm Up to 1 mg litre or ppm Up to 10 mg litre or ppm Up to 200 mg litre or ppm Up to 25 mg litre or ppm Up to 200 mg litre or ppm The warranty will be rendered void in the following circumstances 1 Failure due to misuse Acts of God accidental damage installation by an installer who is not unauthorised to install an Eternity water heater or incorrect installat...
Страница 28: ...hanger Parts 5 Years Labour 1 Year All Other Parts Parts 1 Year Labour 1 Year Definition of Domestic Use 1 Units installed in any domestic dwelling 2 Units installed in any gas boosted solar system in a domestic dwelling 3 Units used in any household applications Definition of Commercial Use 1 Units supplying kitchen areas used for bulk food preparation 2 Units used in industrial or bulk heating p...