Premier150 Spot
Eternal Lighting Feb 2016
DMX OUT DMX IN
2 1
3 PIN
DMX OUT DMX IN
5
1 5
5 PIN
4 2 2 4
3 3
Connection between controller and projector and between one projector and another must be made
with a 2 core-screened cable, with each core having at least a 0.5mm diameter.
Connection to and from the projector is via cannon 5 pin (which are included with the projector) or 3
pin XLR plugs and sockets. The XLR's are connected as shown in the figure above.
Note: care should be taken to ensure that none of the pins touch the metallic body of the plug or each
other. The body of the plug is not connected in any way. The projector accepts digital control signals in
protocol DMX512 (1990).
Connect the controller’s output to the first fixture’s input, and connect the first fixture’s output to the
second fixture’s input and connect the rest fixtures in the same way. Eventually connect the last
fixture’s output to a DMX terminator as shown in the figure below.
DMX Terminator
In the Controller mode, at the last fixture in the chain, the DMX output has to be connected with a
DMX terminator. This prevents electrical noise from disturbing and corrupting the DMX control
signals.
The DMX terminator is simply an XLR connector with a 120
Ω(ohm) resistor connected across pins
2 and 3, which is then plugged into the output socket on the last projector in the chain.
Setup Options
The Premier150 Spot configuration can be set convenient ly by pressing the buttons on the LCD
display. To browse or change the setup options, press EN TER to unlock the panel. Menu will be
displayed on the screen; each menu has its own sub- menu. Each menu has specific function, refer to
“Operation Menu” for detals.
FUNC D OWN UP EN TER
DMX512
PI N
FUNCTION
1
GND
2
DATA-
3
DATA
+
DMX512
PI N
FUNCTION
1
GND
2
DATA-
3
DATA+
4
N/C
5
N/C