READ THIS FIRST:
Check the pack and make sure you have all of the parts
listed on the front of this booklet. If not, contact the
outlet where you bought this product.
This product contains glass, care must be taken when
assembling, fitting or handling to prevent personal
injury or damage to the product.
This light fitting must be installed by a competent
person in accordance with the Building Regulations
making reference to the current edition of the IEE Wiring
Regulations (BS7671). The Building Regulations may be
obtained from HMSO or viewed and downloaded from
www.communities.gov.uk following the link for Building
Regulations.
As the buyer, installer and/or user of this product it is
your own responsibility to ensure that this fitting is fit
for the purpose for which you have intended it. Eterna
Lighting cannot accept any liability for loss, damage or
premature failure resulting from inappropriate use.
This product is designed and constructed according to
the principles of the appropriate British Standard and
is intended for normal domestic service. Use of this
fitting in any other environment, for example where
prolonged periods of use may be expected and/or
higher than normal ambient temperatures, may result in
a foreshortened working life.
The lamps (tubes) supplied with this fitting are
consumable parts and therefore may be outside of any
warranty offered.
Disconnect the fitting from the electrical supply before
flash or high voltage testing.
Suitable for indoor use only.
This product is suitable for use in living areas, and
Bathroom dry (Outside) Zones only (see diagram below
and current IEE Wiring Regulations for details). It is
not suitable for Bathroom Zones 0, 1, 2, or other areas
where contact with moisture is likely. If being fitted in a
bathroom a 30mA RCD must be used.
This product is suitable for installation on surfaces with
normal flammability (indicated by the “F” in a triangle)
e.g. wood, plasterboard, masonry. It is not suitable for
use on highly flammable surfaces (e.g. polystyrene,
textiles).
Before making fixing hole(s), check that there are no
obstructions hidden beneath the mounting surface such
as pipes or cables.
The chosen location of your new fitting should allow
for the product to be securely mounted and safely
connected to the mains supply.
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive (e.g.
metallic surfaces).
If the location of your new fitting requires the provision
of a new electrical supply, the supply must conform
with the requirements of the Building Regulations
making reference to the current edition of the IEE Wiring
Regulations (BS7671).
This product is designed for permanent connection to
fixed wiring: this should be either a suitable lighting
circuit (protected with a 5 or 6 Amp MCB or fuse) or a
fused spur (with a 3 Amp fuse) via a fused connection
unit. We recommend that the supply incorporates a
switch for ease of operation.
The cores in the mains lead are coloured in accordance
with the following code:
Live - Brown or Red
Neutral - Blue or Black
When making connections, ensure that the terminals are
tightened securely and that no strands of wire protrude.
Check that the terminals are tightened onto the bared
conductors and not onto any insulation. Wrap loose
terminal blocks well with insulating tape.
This product is double insulated; do not connect either
the Blue wire or the Brown wire to the Earth terminal.
IMPORTANT:
Always switch off at the socket and
remove the plug before changing the lamp.
A maximum of six fittings may be linked together in one
chain.
You are advised at every stage of your installation to
double-check any electrical connections you have made.
After you have completed your installation there are
electrical tests that should be carried out: these tests are
specified in the Wiring Regulations (BS7671) referred to
in the Building Regulations.
LAMP REPLACEMENT:
01) Switch off the electricity at the mains.
02) Remove the diffuser (diffuser model) or tube
retaining brackets (non-diffused model).
03) Rotate the tube through 90° at both ends and pull it
out of the gap.
04) Fit only Eterna® branded tubes of the same type
and size.
05) Re-fit the diffuser or tube retaining brackets.
REPLACEMENT LAMP TYPE:
TUS6NL
requires 1 x 6W G5 T4 220mm fluorescent tube
3400K (N64/1). Fitting is rated at 6W max.
TUS10NL
requires 1 x 10W G5 T4 341mm fluorescent
tube 3400K (N64/3). Fitting is rated at 10W max.
TUS16NL
requires 1 x 16W G5 T4 468mm fluorescent
tube 3400K (N64/5). Fitting is rated at 16W max.
TUS20NL
requires 1 x 20W G5 T4 567mm fluorescent
tube 3400K (N64/7). Fitting is rated at 20W max.
INSTALLATION:
01) When positioning the fitting, make sure there is a
gap of at least 10mm between the lamp and any
adjacent surface. See below:
02) Select the type of brackets you need to use and
mark off the fixing points. If fixing to a shelf or under
a cupboard, check the screw size required and screw
into place. (See above for clip positions).
03) If fixing directly to the wall, drill holes using a
suitable drill bit to a depth of 30mm and insert wall
plugs.
04) Secure the selected brackets in place using the
screws supplied.
05) Attach the fitting to the clips.
06) Connect the mains lead or link lead to the socket on
your fitting.
07) Restore the power supply and switch on.
WARNING:
The leads supplied with your light fitting and the
sockets incorporated in your fitting are designed to give
protection against any possible electrical hazard. The
mains lead is terminated in a socket marked NLS and
this lead should be used to supply mains to your fitting
or chain of fittings. Under no circumstances should you
attempt to adapt the link lead to supply power to the
opposite end of your fitting as this will leave live pins
exposed at the mains input end of the fitting. Altering
or adapting any of the leads, other than shortening the
mains supply lead, will invalidate your guarantee and
could present a severe electrical shock hazard.
HOW TO LINK MULTIPLE FITTINGS
TOGETHER:
OPTION 1 (REFER TO FIG. 1 ABOVE)
The light fittings can be butted together to form a line
of up to a maximum of 6 fittings. Simply remove the
connector caps and push the fittings together. Use the
mains lead cable to connect the first fitting and the
mains via a spur or junction box (not supplied).
OPTION 2 (REFER TO FIG. 2 ABOVE)
Connect link leads between each fitting and once all
lights have been connected, connect the mains lead to
the mains via a spur or junction box (not supplied).
225cm
60cm
240cm
60cm
radius
from tap
ZONE 1
ZONE 0
ZONE 2
ZONE 2
Bathroom Zones Diagram
10mm Gap
End V
iew
End View
10mm Gap
“U Clip”
“F Clip”
Mains via a spur
or junction box
Mains via a spur
or junction box
Eterna Link Leads Available:
NL1WH / NL50WH / NL25WH
Mains via a spur
or junction box
Eterna Transformer Available: D034
Fig 2
Fig 1
874/2012
A
MODELNO.
TUS Range
Code
kwh /
1000h
N64/1
7.80
N64/3
12.67
N64/5
19.74
N64/7
24.31
A
Replacement lamps available: N64/1, N64/3, N64/5, N64/7