background image

Safety markings:

 

Read this first: 

 

>

This  light  fitting  must  be  installed  in 
accordance  with  the  Building  Regulations.

 

These may be obtained from HMSO or viewed 
and  downloaded  from  www.odpm.gov.uk 
following the link for Building Regulations.

 

>

If  in  any  doubt,  consult  a  qualified 
electrician. 

>

Switch  off  the  mains  before  commencing 
installation  and  remove  the  appropriate  circuit 
fuse. 

>

Do not use the fitting without the safety shield 
fitted. 

>

Replace  the  safety  shield  if  it  is  cracked  or 
broken. 

>

When  replacing  the  lamp,  do  not  touch  with 
bare  fingers,  grip  the  lamp  with  a  tissue  or 
clean soft cloth. 

>

Do  not  connect  to  a  circuit  which  also  has 
inductive loads connected as spikes generated 
switching  inductive  loads  may  damage 
electronic  components  within  your  PIR 
detector and may cause false triggering. 

>

Suitable for outdoor use. 

>

This  product  is  suitable  for  installation  on 
surfaces  with  normal  flammability  (  indicated 
by  the  "F"  in  a  triangle  )    e.g.  wood, 
plasterboard,  masonry.    It  is  not  suitable  for 
use  on  highly  flammable  surfaces  (  e.g. 
polystyrene, textiles ). 

>

Before  making  fixing  hole(s), check that  there 
are  no  obstructions  hidden  beneath  the 
mounting surface such as pipes or cables. 

>

The chosen location of your new fitting should 
allow  for  the  product  to  be  securely  mounted 
and  safely  connected  to  the  mains  supply 
( lighting circuit ). 

>

If  the  location  of your  new  fitting  requires  the 
provision of a new electrical supply, the supply 
must  conform  with  the  requirements  of  the 
Building Regulations. 

>

This  product  is  designed  for  permanent 
connection to fixed wiring: this should be either 
a suitable lighting circuit ( protected with a 5 or 
6 Amp MCB or fuse ) or a fused spur ( with a 3 
Amp  fuse  )  via  a  fused  connection  unit.  We 
recommend  that  the  supply  incorporates  a 

switch for ease of operation. 

>

Make  connections  to  the  electrical  supply  in 
accordance with the following code: 

Live - Brown or Red 
Neutral - Blue or Black 
Earth - Green and Yellow 

>

Additional  red  wires  may  be  present  that  are 
connected  to  the  ring  live  circuit.  Do  not 
connect  your  fitting  to  these  wires.  If  these 
wires are not separately terminated, join them 
together  in  a  separate  terminal  block  (  not 
supplied ), ensure that there are no strands of 
wire  protruding  from  the  terminals  and  wrap 
well with insulating tape. 

>

This product must be connected to Earth.

 

>

You  are  advised  at  every  stage  of  your 
installation  to  double-check  any  electrical 
connections  you  have  made.  After  you  have 
completed your installation there are electrical 
tests that should be carried out: these tests are 
specified in the Wiring Regulations ( BS7671 ) 
referred  to  in  the  Building  Regulations.  If  in 
doubt, consult a qualified electrician.

 

 
 

Installation: 

 
Choose  the  location  of  you  new  light  fitting  giving 
consideration to the following points: 

a)  Avoid positioning the unit close to trees  o r 
shrubs  that  may cause  false  triggering  during 
wet or windy weather. 
b)    Avoid  positioning  the  unit  close  to  heat 
sources such as boiler flues which may cause 
false triggering, 
c)    Avoid  positioning  the  unit  close  to  bright 
artificial  light  sources  which  will  prevent  the 
unit from operating when the lux control is set 
for operation in dark conditions. 
d)    PIR  detectors  are  most  sensitive  to 
movement across the field of detection. 

1) Remove the diffuser from the front of the fitting 

by  inserting  a  wide  bladed  screwdriver  into 
each  of  the slots  at  the  side  of  the  diffuser  in 
turn, and twisting gently to release. 

2) Remove  the  translucent  cover  in  front  of  the 

lampholder by first removing the small screw in 
the top left hand corner. 

3) Using  the  fitting  as  a  template,  mark  the 

position  of  the  fixing  holes  on  your  mounting 
surface,  taking  into  account  the  position  of 

IP44 

your  emerging  supply  cable  and  the  cable 
entry point in the fitting. 

4) Pierce  the  rubber  grommet  in  the  cable  entry 

and  thread  your  supply  cable  through  the 
grommet. The grommet should be a tight fit on 
the cable to maintain a good water-tight seal. 

5) Secure  your  fitting  in  place  using  suitable 

fixings ( not supplied ). 

6) Replace  the  translucent  cover  in  front  of  the 

lampholder  and  secure  using  the  screw 
removed earlier. 

7) Fit a light bulb observing the maximum wattage 

marked on the side of the fitting and listed on 
the back of this leaflet. 

8) Press the diffuser into place ensuring that all of 

the  retaining  clips  have  snapped  into  position 
correctly and that the diffuser is secure. 

9) Adjust the position of the PIR detector to cover 

the desired area. 

10) You  can  check  the  operation  of  the  PIR 

detector  by  performing  a  “walk  test”,  see 
below. 

11) Restore the power and switch on. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Time on adjustment. 
( TIME control ) 

 
Turning the time control clockwise reduces the time 
that  the  light  stays  on  after  activation.  Turning  it 
anti-clockwise increases the time the light stays on 
after activation. 
 

Lux level adjustment 
( LUX control ) 

 
Turning the lux control anti-clockwise ( towards the 
sun  symbol  )  increases  the  ambient  light  level  in 
which  the  PIR  will  operate.  Turning  it  clockwise 
(  towards  the  moon  symbol  )  will  decrease  the 
ambient light level in which the PIR will operate. 

 

Walk test 

 

Turn the Lux adjustment control fuly anti-clockwise 
( towards the sun symbol ) and the time control fully 
clockwise. The fitting will now operate in full daylight 
and  stay  on  for  between  5  and  15  seconds  after 
each detection. 
Adjust the position of the PIR detector so that it is 
triggered by movement in the desired area. Further 
adjustment can be made by blanking out sections of 
the PIR window with opaque tape ( not supplied ). 
 
After satisfactory completion of the walk test, the lux 
adjustment needs to be set to allow operation of the 
light in darkness. At a time when the ambient light is 
at the level you want your light to turn on, turn the 
lux  control  clockwise  ( towards the  moon  symbol  ) 
until  the  light  ceases  to  operate  and  then  back 
slightly.  Repeat  adjustments  over  following  nights 
until the operation of the light is as desired. 
 
Adjust  the  time  setting  so  that  the  light  remains 
illuminated for the desired length of time. 

P

IR

15

0&

50

0-

11

H

al

og

en

 F

lo

od

lig

ht

 0

50

32

4-

Technical information 

 
Operating Voltage:                 230Vac 
Detection angle:                     120° 
Maximum detection range:     12m 
Time on:                                 adjustable between 5-15 seconds and 8-10 minutes 
Lux level adjustable 