background image

DETECTION AREA

1

2

I

100%

II

75%

III

50%

IV

10%

KEY:    ON: 

 

OFF: 

DAYLIGHT SENSOR

5

6

I

Disable

II

50 Lux

III

10 Lux

IV

2 Lux

KEY:    ON: 

 

OFF: 

HOLD TIME

3

4

I

5s

II

90s

III

5min

IV

15min

KEY:    ON: 

 

OFF: 

READ THIS FIRST:

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, 

contact the outlet where you bought this product.

This product must be installed by a competent 

person in accordance with the current building and 

IEE wiring regulations.

As the buyer, installer and/or user of this product it 

is your own responsibility to ensure that this fitting 

is fit for the purpose for which you have intended 

it. Eterna Lighting cannot accept any liability for 

loss, damage or premature failure resulting from 

inappropriate use.

This product is designed and constructed according 

to the principles of the appropriate British Standard 

and is intended for normal domestic service.

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse or lock off 

MCB.

This product is designed for permanent connection 

to fixed wiring: this must be a suitable circuit 

(protected with the appropriate MCB or fuse).   

When making connections ensure that the terminals 

are tightened securely and that no strands of wire 

protrude. Check that the terminals are tightened 

onto the bared conductors and not onto any 

insulation. 

This product is double insulated. 

DO NOT CONNECT 

ANY PART TO EARTH.

This product is not intended to be used by children 

and persons with sensory, physical and/or mental 

impairments that would prevent them from using it 

safely.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation 

there are electrical tests that should be carried out, 

these tests are specified in the current IEE wiring and 

building regulations.

 

 

INTRODUCTION:

This is a microwave sensing device which continuously 

scans the operating zone and immediately switches 

the light on when it detects movement in that area.  

This means that whenever movement is detected 

within the range of the sensor the light will switch 

on automatically and illuminate the area you have 

selected to light.  While there is movement within 

range of the unit the light will remain on. 

A microwave sensor is an active motion detector 

emitting high-frequency electro-magnetic waves at 

5.8GHz and receiving their echo. The sensor detects 

change in the echo pattern within its detection 

zone and the light is then triggered. The wave can 

pass through doors, glass and thin walls and will 

continually monitor the signal within the detection 

area. 

 

 

MICROWAVE SENSOR SPECIFICATIONS:

 

INSTALLATION:

Isolate mains and lock off.

1)  Connect mains and output as per below image, 

brown to live, blue to neutral on input and adjust 

control accordingly.

2)  Restore the power and switch on.

UNDERSTANDING THE CONTROLS:

The sensor is an active motion detector: it emits a 

high frequency electromagnetic wave 5.8GHz and 

receives its echo. The sensor detects the change 

in echo from movement in its detection zone. A 

microprocessor then triggers the switch light ON 

command. Detection is possible through doors, 

panels of glass and thin walls.

 

DETECTION RANGE:

This determines the effective range of the motion 

detector and is set up by DIP switches at the 

sensor itself, refer to figure. Note that reducing the 

sensitivity will also narrow the detection range.
The following settings  

are available:
I - Detection Range 100% 

II - Detection Range 75% 

III - Detection Range 50% 

IV - Detection Range 10%

 

 

HOLD TIME:

This determines the time the fitting remains at 

100% level on motion detection and is set with DIP 

switches at the sensor itself, refer to figure. The walk 

test setting is useful when installing the fitting to 

establish correct operation and range.
The following settings  

are available:
I - Walk test mode 5s 

II - 90s 

III - 5 minutes 

IV - 15 minutes

 

 

DAYLIGHT SENSOR:

This setting holds off the 100% light output should 

there be sufficient daylight and is set using DIP 

switches at the sensor, refer to figure.
The following settings are available:
I - Photocell disabled 

II - 50 lux twilight operation 

III - 10 lux twilight operation 

IV - 2 lux darkness operation only
* In daylight setting the  

lamp(s) will always be on  

with motion detected  

and operate at 100% light  

output, even in bright  

daylight.

1-2 Detection 

Area

Daylight 

Sensor

Power 

Supply

220-240V 

Out Control

Off / On

3-4 Hold 

Time

5-6 Daylight 

Threshold

Microwave 

Sensor

OFF ON

PRODUCT 

TYPE

MICROWAVE 

MOTION SENSOR

Operating Voltage

220-240VAC 50/60Hz

HF System

5.8GHz CW radar

Transmission Power

<0.2mW

Detection Angle

30-150 Degree

Power Consumption

<0.5W

Detection Range

Max. 10m adjustable

Time Setting

5s-15m

Mounting

Indoors, ceiling and wall

Light Control

2-50lux, disable

Working Temp

-20 to +60 degree

Rated Load

800W (resistive load) 

400W (capacitive load) 

270W (LED)

RED DIRECTIVE 

           Eterna Lighting Ltd

Microwave Occupancy Sensor

Full declaration available at www.eterna-lighting.co.uk

Отзывы: