background image

Safety markings:                                                                     

 

Read this first: 

 
 

This  fitting  must  be  installed  in 

accordance  with  the  Building 

Regulations.

  These  may  be  obtained 

from HMSO or viewed and downloaded 
from  www.odpm.gov.uk  following  the 
link for Building Regulations.

 

If  in  any  doubt,  consult  a  qualified 

electrician. 

Switch  off  the  mains  before 
commencing  installation  and  remove 

the appropriate circuit fuse. 

Do  not  use  the  dryer  without  the  front 
cover fitted. 

Disconnect  the  hand  dryer  from  the 
electrical supply before flash or 
high voltage testing. 

Suitable for indoor use only.

 

WARNING:  This  product 

becomes hot ! 

This product is not intended to 
be  used  by  children  and  persons  with 
sensory,  physical  and/or  mental 

impairments  that  would  prevent  them 
from using it safely. 

This  product  is  suitable  for  installation 

on  surfaces  with  normal  flammability 
( indicated by the "F" in a triangle )  e.g. 
wood, plasterboard, masonry.  It is not 
suitable  for  use  on  highly  flammable 
surfaces ( e.g. polystyrene, textiles ). 

Before making fixing hole(s), check that 
there  are  no  obstructions  hidden 
beneath  the mounting  surface  such  as 
pipes or cables. 

The chosen location of your new fitting 
should  allow  for  the  product  to  be 
securely mounted and safely connected 

to the mains supply. 

The  dryer  must  be  positioned  so  that 
there  is  at  least  0.8m  (800  mm) 
between  the  air  outlet  and  the  surface 
beneath. 

If  the  location  of  your  new  fitting 
requires  the  provision  of  a  new 
electrical  supply,  the  supply  must 
conform  with  the  requirements  of  the 
Building Regulations. 

This product is designed for permanent 
connection  to  fixed  wiring  via  a  fused 
spur  (  with  a  13  Amp  fuse  )  .  We 

recommend  that  the  supply 
incorporates  a  switch  for  ease  of 
operation. 

Make  connections  to  the  electrical 

supply in accordance with the following 
code: 

Live - Brown or Red 
Neutral - Blue or Black 
Earth - Green and Yellow 

This  product  must  be  connected  to 
Earth. 

You are advised at every stage of your 
installation  to  double-check  any 
electrical  connections  you  have  made. 
After  you  have  completed  your 
installation there are electrical tests that 

should  be  carried  out:  these  tests  are 
specified  in  the  Wiring  Regulations 
(  BS7671  )  referred  to  in  the  Building 
Regulations.  If  in  doubt,  consult  a 
qualified electrician. 

 

IPX1 

Installation: 

 
 
1)  Select the location of your new dryer with 

consideration to the conditions opposite. 

2)  Remove  the  two  case  screws  from  the 

bottom  of  the  dryer  and  remove  the 
case. 

3)  Mark  the  location  of  the  fixing  holes 

using    the  back  of  the  dryer  as  a 
template. 

4)  Secure the back of the dryer to the wall 

using  the  fixings  supplied.  If  the  fixings 
supplied  are  not  appropriate  to  your 
installation,  please  select  suitable 

alternatives. 

5)  Make  the  supply  connections  according 

to the colour code opposite. 

6)  Temporarily  restore  the  power 

supply-beware  parts  of    the 

motor that are live and that are 

accessible to touch. 

7)  Move your hands beneath the sensor to 

replicate  hand  drying  movement..  The 

dryer  should  operate  when  you  move 
your hands beneath the sensor and stop 
when your hands are withdrawn. 

8)  If  the  dryer  does  not  respond  correctly, 

you  can  adjust  the  sensitivity  of  the 
sensor  by  turning  the  screw  as  shown 

below. 

9)  Turn off the power at the mains. 
10) Replace  the  cover  and  refit  the  two 

screws  on  the  underside  ensuring  they 
are tight. 

11) Restore the power. 
 
 

H

D

A

-1

80

0–

 1

.8

K

W

 A

ut

om

at

ic

 H

an

D

ry

er

 0

80

71

6P

A

 

To adjust sensitivity use a small 

flat blade screwdriver and turn 

the screw on the square shaped, 

blue potentiometer 

Отзывы: