INSTALLATION:

01)  Switch off the mains before commencing 

installation.

02)  Using the bracket as a template mark and then 

drill the appropriate fixing holes.

03)  Secure the bracket with suitable fixings.

04)  Unscrew connector on back of fitting and make 

the electrical connections: 

 

Live - Brown / Red 

Neutral - Blue / Black 

Earth - Yellow / Green

05)  Ensure the connector is secured tightly to 

maintain IP rating.

06)  Adjust the direction of the floodlight and tighten 

the fixings on the back of the fitting.

07) Restore mains power.
08)  Adjust the PIR sensor to the desired settings.
 

UNDERSTANDING THE CONTROLS:

 (Please refer to Fig. 5 / 6 below)

ADJUSTING THE DURATION TIME:

 

The length of time the unit remains switched on 

after activation can be adjusted from (10±3) seconds 

to (10±3) minutes approximately. Rotating the TIME 

screw from (+) to (-) will reduce the duration time.  

Note:

 Once the light has been triggered by the PIR 

sensor any subsequent detection will start the timed 

period again from the beginning.

 

ADJUSTING THE LUX CONTROL LEVEL: 

The Lux control module has a built-in sensing device 

(photocell) that detects daylight and darkness. The 

(

R

) position denotes that the floodlights can work 

at day and night, and the (

) position only work at 

night. You can set to operate the unit at the desired 

level by adjusting the LUX screw.

 

SETTING THE CONTROLS - WALK TEST:

Turn the Lux control screw to light (

R

) & ensure 

that the TIME control screw is set at the minimum 

duration time (-) position. The floodlight will now 

switch on and remain on for about 10 seconds after 

each detection.
01) Adjust time control to required setting.
02)  To set the light level at which the floodlight will 

automatically switch “on” at night, turn the LUX 

control screw from daylight (

R

) to night (

). If 

the floodlight is required to switch on earlier, e.g. 

dusk, wait for the desired light level, then slowly 

turn the LUX control screw towards daylight while 

someone walks across the center of the area to 

be detected. When the floodlight switches on 

stop adjusting. You may need to make further 

adjustments to achieve your ideal light level 

setting.

 

(50W VERSION ONLY) ADJUSTING THE 

SENSITIVITY:

The sensitivity means the maximum distance which 

PIR sensor can be triggered by movement - turning 

the SENS knob from (+) to (-) will decrease the 

sensitivity.

CLEANING:

•  To avoid dust build-up and ensure proper 

functioning of the floodlight, please wipe the 

sensor lens lightly with a damp cloth every 3 

months.

•  Disconnect the power and clean the exterior only of 

this fitting with a moist (not wet) cloth.

• Do not use any chemical or abrasive cleaners.

TROUBLESHOOTING AND USER HINTS:

Note:

 all passive infra red detectors are more sensitive in cold and dry weather than warm and wet weather.

PROBLEM

POSSIBLE CAUSE

SUGGESTED REMEDY

Light does not switch on 

when there is movement 

in the detection area.

1. No mains voltage

Check all connections, and MCB Fuses / switches

2. Nearby lighting is too bright

Relocate the unit

3. Controls set incorrectly

Adjust Lux setting

4. Wired incorrectly

Check wiring and confirm its wired as per the 

wiring instructions opposite

5. Sensor positioned in wrong direction

Relocate the unit

Light switches on for no 

apparent reason (false 

trigger)

1.  Heat sources such as air-con, vents, heaters, flues, 

other outside lighting, moving cars trees or shrubs 

are activating sensor

Relocate the unit

2.  Interference from on/off switching of electric 

fans or lights on the same circuit as your security 

floodlight. 

(This problem does not always occur but a faulty 

switch or noisy fluorescent light may cause the 

security floodlight to switch on)

Should the false triggering become, troublesome, 

consider:
(a) Replacing a faulty switch
(b)  Replacing noisy fluorescent tubes and/or 

starters

(c)  Connecting the floodlight to a separate 

circuit (in most cases where one or more of 

the above suggestions have been carried out, 

false triggering has been reduced)

3.  Reflection from swimming pool, or reflective 

surface such as smooth white walls 

Relocate the unit

Light remains on

Time is set too long

Reduce time

Light remains on at 

nighttime

Possible heat source in detection zone

Cover PIR sensor lens with a thick cloth, if the 

light turns off check detection area for heat or 

reflective source, reposition head and decrease 

the sensitivity setting if this control is available

Light switches on during 

daylight hours

LUX control screw is set to daylight position

Turn the LUX control screw to desired light level 

setting

When setting the lux 

controls in daylight 

the detection distance 

becomes shorter

Interference by sunlight

Re-test at night

Fig 5: 10-30W PIR Controls

Fig 6: 50W PIR Controls

PG 4

PG 5

TIME

LUX

TIME

LUX

SENS

EVENTUALLY, YOU MAY WANT TO 

REPLACE THIS PRODUCT:

Regulations require the recycling of Waste from 

Electrical and Electronic Equipment (European 

“WEEE Directive” effective August 2005—UK 

WEEE Regulations effective 2nd January 2007). 

Environment Agency Registered Producer: WEE/

GA0248QZ. 

WHEN YOUR PRODUCT COMES TO THE END OF 

ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE 

RECYCLE IT WHERE FACILITIES EXIST - DO NOT 

DISPOSE WITH HOUSEHOLD WASTE.

IF YOU EXPERIENCE PROBLEMS:

If you believe your product is defective, please return 

it to the place where you bought it. Our Technical 

Team will gladly advise on any Eterna Lighting 

product, but may not be able to give specific 

instructions regarding individual installations. 

 

LAMP REPLACEMENT:

The light source contained in this luminaire 

shall only be replaced by the manufacturer, 

service agent or a similar qualified person. 

CAUTION, RISK OF ELECTRIC SHOCK.