Installation

1.   Choose the location for your new floodlight giving 

consideration to all of the conditions listed.

2.   Undo the nuts and bolts that hold the fixing strap 

onto the fitting noting the order and position of the 

various washers.

3.   Using the fixing strap as a template, mark the 

position for the fixing holes on your mounting 

surface.

4.   Prepare your mounting surface as appropriate for 

your chosen fixings (not supplied). Use a spirit level 

to ensure the fitting will be level.

5.  Secure the fixing strap in place.

6.   Attach the fitting onto the fixing strap using the 

fixings removed earlier, adjust the angle of your 

floodlight to give the desired spread of light.

7.   Tighten the nuts to lock your floodlight into 

position.

8.   Make your connections to your mains supply as 

described in the “Read this first” section.

9.   Using a wide flat bladed screwdriver, lever the trim 

off the front of the floodlight.

10.  Using a cross-headed screwdriver, undo the screws 

that secure the diffuser and lift off.

11.  Fit the fluorescent lamp: Note the position of the 

lamp pins and push the lamp into the lampholder 

so that the pins engage in the holes in the socket. 

Make sure the lamp is pressed fully into position.

12.  Replace the diffuser and tighten making sure that 

the waterproof gasket is correctly positioned and 

compressed.

13.  Press the trim back onto the front of the fitting 

making sure the slots used for removal are at the 

bottom.

14.  Restore the power and switch on.

15.  

FL157B:

 The fitting should light when switched on. 

 

FL157BPC:

 The fitting will light when the power 

has been restored and the ambient light level falls 

below the preset threshold (not adjustable).

Safety Markings

Cleaning

Disconnect the power and clean the exterior only of 

this fitting with a moist (not wet) cloth.

Do not use any chemical or abrasive cleaners.

 

Lamp Replacement

1.  Switch off the electricity at the mains.

2.   Using a wide flat bladed screwdriver, lever off the 

trim from the front of the fitting.

3.   Using a cross-headed screwdriver, loosen the 

screws and lift off the diffuser.

4.  Remove the lamp by pulling directly to the side.

5.   Press a new lamp into position noting the position 

of the lamp pins and holes in the lampholder.

6.   Push the lamp firmly to ensure that it is correctly 

engaged in the lampholder.

7.   Replace the diffuser and secure in position making 

sure that the gasket is correctly positioned and 

compressed.

8.   Press the trim back onto the fitting making sure 

that the slots used for removal are at the bottom.

9.  Restore the power and switch on.

 

Replacement Lamp Type

Wattage: 57W 

Type: GX24q-5 triple turn T 4pin CFL 6400K

General Information and Safety Instructions

Read this first

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, contact 

the outlet where you bought this product.

This product contains glass, care must be taken when 

assembling, fitting or handling to prevent personal 

injury or damage to the product.

This light fitting must be installed by a competent 

person in accordance with the Building Regulations

 

making reference to the current edition of the IEE 

Wiring Regulations (BS7671). The Building Regulations 

may be obtained from HMSO or viewed and 

downloaded from www.communities.gov.uk following 

the link for Building Regulations.

As the buyer, installer and/or user of this product it is 

your own responsibility to ensure that this fitting is fit 

for the purpose for which you have intended it. Eterna 

Lighting cannot accept any liability for loss, damage or 

premature failure resulting from inappropriate use.

If in any doubt, consult a qualified electrician.

The lamps (bulbs/tubes) supplied with this fitting are 

consumable parts and therefore may be outside of any 

warranty offered.

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse.

When working at heights, please use a suitable 

platform. 

Disconnect the fitting from the electrical supply before 

flash or high voltage testing.

Suitable for indoor and outdoor use.

FL157BPC - Do not install under eaves or in a location 

of frequent shadow that will prevent the light from 

switching on when required. Do not install near other 

sources of bright light that will prevent the light from 

switching on when the ambient light level falls.

This product is suitable for installation on surfaces 

with normal flammability e.g. wood, plasterboard, and 

masonry.  It is not suitable for use on highly flammable 

surfaces (e.g. polystyrene, textiles). 

Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.

The chosen location of your new fitting should allow 

for the product to be securely mounted and safely 

connected to the mains supply (lighting circuit).

When choosing the location for your new fitting, 

ensure that the fixings will be anchored in a solid 

surface e.g. concrete, brick or a joist - do not fix directly 

onto panelling, cladding, plasterboard etc.

If the location of your new fitting requires the provision 

of a new electrical supply, the supply must conform 

with the requirements of the Building Regulations 

making reference to the current edition of the IEE 

Wiring Regulations (BS7671).

This product is designed for permanent connection to 

fixed wiring: this should be either a suitable lighting 

circuit (protected with a 5 or 6 Amp MCB or fuse) or a 

fused spur (with a 3 Amp fuse) via a fused connection 

unit. If the connection to your fitting is to be made 

in a humid or wet location, the connections must 

be contained within an approved, ingress protected, 

water-proof connection box (not supplied).

We recommend that the supply incorporates a switch 

for ease of operation.

Make connections to the electrical supply in 

accordance with the following code:

Live - Brown or Red 

Neutral - Blue or Black 

Earth - Green and Yellow

When making connections, ensure that the terminals 

are tightened securely and that no strands of wire 

protrude. Check that the terminals are tightened onto 

the bared conductors and not onto any insulation. 

Wrap loose terminal blocks well with insulating tape.

This product must be connected to Earth.

IMPORTANT— Always switch off at the mains before 

changing the lamp.

If the external flexible cable of this luminaire is 

damaged it shall be exclusively replaced by repair or 

service agent or similar qualified person.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation there 

are electrical tests that should be carried out: these 

tests are specified in the Wiring Regulations (BS7671) 

referred to in the Building Regulations. 

If in doubt, consult a qualified electrician.

Installation Instructions and Care