This heater must be installed in accordance with 

the Building Regulations. These may be obtained 

from OPSI or viewed and downloaded from www.

communities.gov.uk following the link for Building 

Regulations.

This heater is designed for wall mounting and 

must be used with the warm air vent facing 

downwards. This heater should not be used in any 

other orientation and should not be used as a free 

standing portable appliance.

ADVISORY:

 This heater must be installed at least 

1.8m above the floor.

This heater must be installed so that switches and 

other controls (except the pull cord) cannot be 

touched by a person in the bath or shower.

The mounting position should allow the free 

movement of air around the heater. Obstructing the 

air flow could result in overheating.

This product is not intended to be used by children 

and persons with sensory, physical and/or mental 

impairments that would prevent them from using it 

safely.

Small children should be supervised to ensure that 

they do not play with this appliance.

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse.

Suitable for indoor use only.

This product is suitable for installation on surfaces 

with normal flammability e.g. wood, plasterboard, 

masonry. It is not suitable for use on highly 

flammable surfaces (e.g. polystyrene, textiles).

Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.

The chosen location of your new heater should allow 

for the product to be securely mounted (e.g. to a firm 

wall) and safely connected to the mains supply.

Do not site the heater directly beneath a mains 

outlet socket.

If the location of your new heater requires the 

provision of a new electrical supply, the supply 

must conform with the requirements of the Building 

Regulations.

This product is designed for permanent connection 

to fixed wiring: this should be to a suitable ring 

circuit (protected with a 10 Amp MCB or fuse) 

or a fused spur (with a 10 Amp fuse) via a fused 

connection unit. The supply must  incorporate a 

switch or other means of disconnection.

This product is not suitable for mounting within 

bathroom zones 0, 1 or 2  – it can be installed 

outside of zones where the permanent connection 

to the mains supply is made in accordance with the 

requirements of building and wiring regulations.

If installed in a bathroom, the supply circuit must be 

protected by a 30mA RCD.

Make connections to the electrical supply in 

accordance with the following code:

Live - Brown or Red • Neutral - Blue or Black

This product is double insulated, do not connect any 

part to Earth.

WARNING

 - To avoid overheating, 

do not cover the heater.

The heater is fitted with 2 stage over-temperature 

protection for protection against brief excess of 

temperature, the heater has a resetting thermostatic 

device; for longer periods of excess temperature or 

higher excess temperatures, the heater is fitted with 

a one-shot thermal fuse which cannot be reset.

As you are making a fixed connection to the mains, 

you are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation 

there are electrical tests that should be carried out: 

these tests are specified in the Wiring Regulations 

(BS7671) referred to in the Building Regulations. 

INSTALLATION:

 

 

01.   Choose the location for your new heater giving 

consideration to all of the points above.

02.  Loosen the two screws at the top of the front of 

the heater and lift off the front cover.

03.  Using the guide diagram above, mark the 

position of the top two fixing holes.

04. Use a spirit level to check holes are level.

05.  Make the top two fixing holes using a suitable 

drill bit.

06.  Insert the plastic plugs and screws leaving 

approximately 3mm of the shank protruding.

07.  Hang the heater on the screws. If the fixings 

supplied are not suitable for your mounting 

surface, select suitable alternatives.

08.  Mark the position of the third fixing hole using 

the heater as a template.

09.  Remove the heater, make the fixing hole and 

insert the plastic plug.

10.  Replace the heater adjusting the top two screws 

to make as tight a fit as possible.

11.  Secure using the third fixing through the hole 

indicated opposite.

12. Remove the cable clamp from inside the heater.

13.  Thread the supply cable through the hole in the 

rear of the case.

14.   Make connections to the supply terminals 

according to the colour code (left). Ensure that 

there are no strands or whiskers protruding from 

the terminals.

15.   Secure the cable under the cable clamp. Ensure 

that the cable is gripped firmly but take care not 

to over-tighten the screws.

16.   This fitting is factory pre-set at 1kW operation 

and 30 minute run back timer. If a different 

output /time is required this can be set upon 

installation. 

 

Select desired mode of operation using the dip 

switches* 

 

 

 

 

 

 

 

 

 

 

 

1 - On position 1kW / Off position 2kW 

2 - On position 5 minutes 

3 - On position 10 minutes 

4 - On position 20 minutes

*You can have multiple time dip switches selected at 

one time, this allows you to add the times together 

e.g dip switch 2 and 3 on = 15 minutes

17. Close and secure the front cover.

18. Restore the power and switch on.

19.  Pull the switch cord to turn the heater on and it 

will automatically switch off when the selected 

Runback time has elapsed. The heater can then 

be restarted by pulling the switch cord twice, 

once to turn off the red indicator and a second 

time to restart the heater.

The heater can be turned off at any time before the 

Runback time has elapsed by pulling the switch cord 

and the red indicator will automatically turn off.

Fixing Hole 
Positions

124mm

67mm

114mm

Terminal block

ACL (Live) • ACN (Neutral)

Dip switches

Fixing Hole