background image

10

Color

Mode

Description

OFF

None

Hair dryer is off.

Green

TP1 (122°F)

The heat sensor will detect your hair temperature and 

automatically adjust the heat to protect hair from damage.

Note:

 The heat level cannot be adjusted manually in  

this mode.

TP2 (149°F)

Purple

Normal (100°–190°F)

The heat level can be adjusted manually.

Note:

 Use caution when drying with temperatures 158°F  

or higher.

Blue

Cool (Approx. 88°F)

The dryer will emit cool air.

Note:

 If the heat level is adjusted, the dryer will exit Cool Mode 

and enter Normal Mode.

Orange

Warning

The heat sensor has detected hair temperatures at 158°F 

(70°C) or above.

The display color will change based on the function or mode currently activated.

Display Colors

Содержание EHD-55

Страница 1: ...1 Questions or Concerns support etekcity com 855 686 3835 Ionic Hair Dryer with Heat Protection Model EHD 55 User Manual ...

Страница 2: ...on Diagram Display Diagram Display Colors Using Your Dryer Care Maintenance Troubleshooting Warranty Information Customer Support 2 3 3 4 8 9 10 11 13 15 16 18 Package Contents Ionic Hair Dryer with Heat Protection Concentrator Attachment Diffuser Attachment User Manual Quick Start Guide 1 1 1 1 1 ...

Страница 3: ...C Accuracy TP1 TP2 Cool Modes 5 F Dimensions 8 5 11 5 3 7 in 21 6 29 2 9 3 cm Weight 1 46 lb 660 g Long life professional DC motor Intelligent Temperature Control TP function Touch control buttons 5 fan speed and 5 heat combination settings Real time hair temperature readings LCD display Cool Air button Negative Ion function Double Overheat Protection Memory function ...

Страница 4: ...ugged in Close supervision is necessary when the dryer is used by on or near children or individuals with certain disabilities Children should be supervised to ensure they do not play with the dryer DANGER As with most electrical appliances electrical parts carry current even when the switch is off WARNING To reduce the risk of burns electrocution fire or injury to persons Do not place or store dr...

Страница 5: ...where aerosol spray products are being used or where oxygen is being administered Do not use the dryer if there is visible damage if it is not working properly or if it has been dropped Regularly check the dryer and its cord for damage If the power supply is abnormal or if the dryer or its cord needs examination or repair contact Customer Service see page 18 Do not repair on your own Repairs that ...

Страница 6: ...check the safety plug to verify that it is in proper working order This appliance is equipped with a thermostat that may cycle OFF if the temperature exceeds comfort level due to the partially blocked air inlet or air outlet openings In the event that the appliance slows down during use turn off the switches and allow the appliance to cool down at which time the thermostat will automatically reset...

Страница 7: ...e personnel Replacement parts for a double insulated appliance must be identical to the parts they replace A double insulated appliance is marked with the words DOUBLE INSULATION or DOUBLE INSULATED The symbol square within a square may also be marked on the appliance This dryer is equipped with a thermostat that may cycle off if the temperature exceeds comfort levels due to the partially blocked ...

Страница 8: ...r Button D Concentrator Attachment E Hanging Loop F Plug G Negative Ion Button H Temperature Control Button I Air Speed Control Button J On Off Button K Intelligent Temperature Control TP Button L Diffuser Attachment M Heat Sensor D C F L E A K G B I H J M ...

Страница 9: ...iagram A Intelligent Temperature Control TP B Cool Air Function C Hair Temperature D Fahrenheit Celsius E Negative Ion Function F Heat Function G Heat Level H Air Speed Function I Air Speed Level A D F I B G H E C ...

Страница 10: ...49 F Purple Normal 100 190 F The heat level can be adjusted manually Note Use caution when drying with temperatures 158 F or higher Blue Cool Approx 88 F The dryer will emit cool air Note If the heat level is adjusted the dryer will exit Cool Mode and enter Normal Mode Orange Warning The heat sensor has detected hair temperatures at 158 F 70 C or above The display color will change based on the fu...

Страница 11: ...t Press to turn on Intelligent Temperature Control and to switch between TP1 122 F TP2 149 F and Normal Mode TP1 122 F is enabled by default Note When Intelligent Temperature Control is on hair temperature is monitored and regulated in real time The hair dryer will automatically maintain hair temperature at 122 F TP1 or 149 F TP2 While Intelligent Temperature Control is on you cannot manually chan...

Страница 12: ...ween level 1 and level 5 Figure 1 2 Note The hair dryer will remember your last used settings Note You must be in Normal Mode to manually control the heat level Figure 1 2 Figure 1 1 6 Optionally press ION to turn the Negative Ion Function on off 7 Optionally press for cool airflow To turn it off press again 8 When you are finished press to turn off the hair dryer before unplugging it Your hair dr...

Страница 13: ...dryer Never immerse the hair dryer in water Overheat Protection This hair dryer does not typically require maintenance Keep all vents and openings clear of dirt and dust If cleaning is necessary unplug the hair dryer and allow it to completely cool Do not allow the hair dryer to come in contact with water or allow moisture or debris to enter the hair dryer while cleaning You can use a slightly dam...

Страница 14: ...sting severe folding or bending may rupture the power cord and cause electrical short circuit or other malfunctions If the cord becomes twisted untwist prior to use When you wish to dispose of this product give it to your local designated recycling center and follow the classification and recycling regulations for electronic products in your country The correct disposal of this product reduces neg...

Страница 15: ...mperature cannot be displayed You will not be able to use Intelligent Temperature Control TP but you can still use the hair dryer in Normal Mode Contact Customer Support see page 18 Display shows Error Code E2 Overheat protection has activated Wait 10 20 minutes to allow the hair dryer to cool then turn it back on The hair dryer should work normally Hair dryer stops heating but the fan still works...

Страница 16: ...t apply If the product has been modified from its original condition If the product has not been used in accordance with directions and instructions in the user manual To damages or defects caused by accident abuse misuse or improper or inadequate maintenance To damages or defects caused by service or repair of the product performed by an unauthorized service provider or by anyone other than Etekc...

Страница 17: ...w the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you If you discover that your product is defective within the specified warranty period please contact Customer Support via support etekcity com DO NOT dispose of your product before contacting us Once our Customer Support Team has approved your request please return the produ...

Страница 18: ... contact our helpful Customer Support Team Distributed by Etekcity 1202 N Miller St Suite A Anaheim CA 92806 Email support etekcity com Toll Free 855 686 3835 Support Hours Monday Friday 9 00 am 5 00 pm PST PDT Please have your invoice and order ID ready before contacting Customer Support ...

Страница 19: ...Notes ...

Страница 20: ...JJ021021CW M1_0121EHD 55 Connect with us Etekcity ...

Отзывы: