©2012 Tyco Electronics Corporation, a TE Connectivity Ltd. company
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or company names may be trademarks of their respective owners.
1
of 2
Instruction Sheet
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at
www.te.com
408-32072
KOAXXA* Series 50-Ohm
Right-Angle Plug Connector Kits for
Flexible Cable
07 NOV 12 Rev A
Figure 1
1. INTRODUCTION
This instruction sheet covers the assembly of KOAXXA
Series 50-ohm right-angle plug connector kits listed in
Figure 1. Each plug connector is designed to be
attached to the flexible cable (solid or stranded) type
and size listed in Figure 1 using the following tooling:
In addition, a small bench vice, solder iron, and 2- to
3-mm punch tool will be needed.
Dimensions in this instruction sheet are in metric
units [with U.S. customary units in brackets].
Figures are not drawn to scale.
NOTE
i
2. DESCRIPTION
Each plug connector kit consists of a right-angle plug
assembly, ferrule, and cap. Kits that use RG-178 or 196
cable also contain a sleeve insert for installing onto the
cable. The heat shrink tubing (available separately,
listed in Figure 1 or a customer supplied equivalent) is
required for assembly of the plug connector kit.
3. ASSEMBLY PROCEDURE
Refer to Figure 1, and select the appropriate cable
type for the plug connector.
Any deviations from this procedure at the discretion
of the assembler could affect the performance of
the plug connector.
3.1. Cable Preparation
1. Strip the cable to the dimensions provided in
Figure 2.
2. Tin the cable center conductor.
Figure 2
3.2. Ferrule Crimp
1. For RG-178 or 196 cable, insert the sleeve insert
into the cable end of the plug assembly until it stops.
See Figure 3, Detail A.
2. Place the heat shrink tubing, then the ferrule,
onto the cable. Flare the cable braid. See Figure 3,
Detail B.
It is important to install the heat shrink tubing for
product reliability and performance.
Right-Angle Plug Assembly
Ferrule
Cap
Sleeve Insert (Included with
Kit SMA-PR-1D Only)
Port Hole (Ref)
Cable End (Ref)
CABLE TYPE AND SIZE
PLUG CONNECTOR KIT
HEAT SHRINK TUBING
(Available Separately)
RD-316 (Double Braid), K0225D
SMA-PR-1B
1403085-5
RG-174, 188, 316
SMA-PR-1F
1403085-2
RG-58, 141, 142, 223, 316, 400
SMA-PR-1G
1403085-1
RG-178, 196
SMA-PR-1D
1403085-2
TOOLING
PART NUMBER
INSTRUCTION
SHEET
PRO-CRIMPER* III Hand
Crimping Tool Assembly
2161732-1 408-32033
Solder Assembly Kit
or Locator Tool
2161890-1
1055451-1
408-32043
—
!
CAUTION
CABLE TYPE AND SIZE
CABLE STRIP LENGTH
mm [in.] ±0.15 [.006]
A
B
C
RD-316 (Double Braid), K0225D, RG-58,
141, 142, 174, 188, 223, 316, 400
2.0
[.078]
6.50
[.256]
9.50
[.374]
RG-178, 196
2.0
[.078]
6.75
[.266]
9.00
[.354]
A
Recommended Cable Strip Length
B
C
Center
Conductor
Dielectric
Cable
Braid
Ferrule
Cable
Jacket
Note:
Not to Scale
NOTE
i