background image

E T C   I n s t a l l a t i o n   G u i d e

Paradigm P-LCD Series

Unison  Paradigm  Wall  Mount  Touchscreen

Page 4 of 4

Electronic Theatre Controls, Inc.

Installing the Touchscreen

The Touchscreen bracket is designed for two positions, service and operation. When installed so that 
the pins are in the first slots on the bracket, the Touchscreen is held out at the bottom for service.

Step 1:

Install the RJ11 control cable provided in the installation kit to the RJ11 jack on the PCB. 

Also attach the RJ45 control cable if PoE will be used for communication and power.

Step 2:

Plug the other end of the cable(s) into the Touchscreen.

Step 3:

Hold the Touchscreen at a slight angle and insert the top first and hook the bracket onto 
the double pins on each side of the collar.

Step 4:

To move the Touchscreen from the service position to the operation position, lift up at the 
bottom and rotate the bottom inward.

Step 5:

Push firmly in and down on the bottom corners of the bezel until it audibly snaps onto the 
collar. When properly installed, the Touchscreen should not easily unsnap from the collar.

Step 6:

To remove the Touchscreen, insert a flat bladed screwdriver into the pry slot and unsnap 
the Touchscreen from the collar. Then lift the bottom upward slightly and rotate outward.

Indicators

After the Touchscreen has been powered up, the appropriate LEDs on the service panel on the bottom 
of the Touchscreen illuminate. The LCD displays a startup screen a few seconds after booting. For 
information about using the service panel, refer to the 

Unison Paradigm Control Designer Configuration 

Guide or Online Help System

.

N o t e :

The RJ11 cable provides the ground connection to the back box and must always 

be installed.

Service position

Operation position

Status

LON

Net

SD card slot

USB Port

Pry slot

Pry slot

Содержание Unison Paradigm P-LCD-FBB

Страница 1: ...r LinkPower and Auxiliary power or PoE Power over Ethernet 802 3af Echelon LinkPower LinkConnect control network utilizing Belden 8471 or approved equal and 24 Vdc Auxiliary power two 16 AWG 1 5mm2 wires PoE Power Over Ethernet 802 3af utilizing Category 5 cable or approved equal All control wiring should be installed and terminated by a qualified installer and should follow standard wiring instal...

Страница 2: ...essary wiring The PCB consists of three parts PCB with female RJ11 LinkPower connector 24 VDC Aux connector and ground spade RJ45 with punch down wire termination Mounting bracket and screws CAUTION Only one network type may be connected to the touchscreen not both Damage may occur if both power types Auxiliary Power and PoE are connected to the touchscreen ETC requires that all back boxes be grou...

Страница 3: ...he red and black Auxiliary power pigtail wires Using two Wago connectors connect the typically red installed wire s with red pigtail wire and connect the typically black installed wire s with black pigtail wire as shown above Step 4 Plug the Auxiliary power connector into the Aux power receptacle on the termination PCB Step 5 A ground connection is required for all Touchscreen assemblies If the ba...

Страница 4: ...rvice position to the operation position lift up at the bottom and rotate the bottom inward Step 5 Push firmly in and down on the bottom corners of the bezel until it audibly snaps onto the collar When properly installed the Touchscreen should not easily unsnap from the collar Step 6 To remove the Touchscreen insert a flat bladed screwdriver into the pry slot and unsnap the Touchscreen from the co...

Отзывы: