E T C
®
I n s t a l l a t i o n G u i d e
Unison
®
Heritage AV/Serial Interface Station
Unison
®
Heritage AV/Serial Interface Station
Page 1 of 3
Electronic Theatre Controls, Inc.
Corporate Headquarters
3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA
Tel +608 831 4116
Fax +608 836 1736
London, UK
Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK
Tel +44 (0)20 8896 1000
Fax +44 (0)20 8896 2000
Rome, IT
Via Ennio Quirino Visconti, 11, 00193 Rome, Italy
Tel +39 (06) 32 111 683
Fax +44 (0) 20 8752 8486
Holzkirchen, DE
Ohmstrasse 3, 83607 Holzkirchen, Germany
Tel +49 (80 24) 47 00-0
Fax +49 (80 24) 47 00-3 00
Hong Kong
Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong
Tel +852 2799 1220
Fax +852 2799 9325
Service:
(Americas)
(UK)
(DE)
(Asia)
Web:
Copyright © 2008 ETC. All Rights Reserved.
Product information and specifications subject to change.
7181M2120
Rev A
Released 10/2008
Overview
The Unison Heritage AV/Serial Interface station (model# UH1AV) provides a
method for any RS232 capable device to control and interact with the Unison
Paradigm LinkConnect control network. The AV/Serial Interface Station acts
as a virtual station with similar functionality to existing Heritage station types
allowing for virtual buttons, faders and rates to be manipulated with serial
commands.
Installation
The AV/Serial Interface Station may be installed into an industry standard
single gang backbox (provided by others) or a single gang surface mounted
backbox (sold separately and available from ETC).
Installation should follow local codes and standard practices. All control wiring should be installed and
terminated by a qualified installer and should follow standard wiring installation practices. Leave
approximately 10 inches (254mm) of wiring in the backbox for connection and future service needs.
AV/Serial Interface wiring requirements include:
•
Connection to the Echelon
®
LinkPower
®
(LinkConnect) control network utilizing low voltage
Class II wiring. Wiring is topology free and polarity independent over Belden 8471 (or
approved equal).
•
Connection of two 16 AWG (1.5mm
2
) wires for 24 Vdc Auxiliary Power.
•
Connection of one 14 AWG (2.5mm
2
) ESD drain (ground) wire. Required only when the
control cable is not installed in grounded metal conduit.
The AV/Serial Interface station ships with a termination kit containing a LinkPower pigtail, Auxiliary
Power pigtail, ground wire pigtail, spacers, and all required connectors for installation.
LinkPower
pigtail
Ground
pigtail
WAGO
Spacers
Auxiliary