background image

E T C

®

  I n s t a l l a t i o n   G u i d e

Unison

®

 Heritage AV/Serial Interface Station

Unison

®

  Heritage  AV/Serial  Interface  Station

Page 1 of 3

Electronic Theatre Controls, Inc.

Corporate Headquarters

 

„

 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA 

„

 Tel +608 831 4116 

„

 Fax +608 836 1736

London, UK

 

„

 Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK 

„

 Tel +44 (0)20 8896 1000 

„

 Fax +44 (0)20 8896 2000

Rome, IT 

„

 

Via Ennio Quirino Visconti, 11, 00193 Rome, Italy 

„

 Tel +39 (06) 32 111 683 

„

 Fax +44 (0) 20 8752 8486

Holzkirchen, DE

 

„

 Ohmstrasse 3, 83607 Holzkirchen, Germany 

„

 Tel +49 (80 24) 47 00-0 

„

 Fax +49 (80 24) 47 00-3 00

Hong Kong 

„

 Rm 1801, 18/F, Tower 1 Phase 1, Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong 

„

 Tel +852 2799 1220 

„

 Fax +852 2799 9325

Service: 

(Americas)

 [email protected]

 

„

 

(UK)

 [email protected]

 

„

 (DE)

 [email protected]

 

„

 

(Asia)

 [email protected]

Web:

 www.etcconnect.com

 

„

 Copyright © 2008 ETC. All Rights Reserved. 

„

 Product information and specifications subject to change.

7181M2120

 

„

 Rev A 

„

 Released 10/2008

Overview

The Unison Heritage AV/Serial Interface station (model# UH1AV) provides a 
method for any RS232 capable device to control and interact with the Unison 
Paradigm LinkConnect control network. The AV/Serial Interface Station acts 
as a virtual station with similar functionality to existing Heritage station types 
allowing for virtual buttons, faders and rates to be manipulated with serial 
commands.

Installation

The AV/Serial Interface Station may be installed into an industry standard 
single gang backbox (provided by others) or a single gang surface mounted 
backbox (sold separately and available from ETC).

Installation should follow local codes and standard practices. All control wiring should be installed and 
terminated by a qualified installer and should follow standard wiring installation practices. Leave 
approximately 10 inches (254mm) of wiring in the backbox for connection and future service needs.

AV/Serial Interface wiring requirements include:

Connection to the Echelon

®

 LinkPower

® 

(LinkConnect) control network utilizing low voltage 

Class II wiring. Wiring is topology free and polarity independent over Belden 8471 (or 

approved equal).

Connection of two 16 AWG (1.5mm

2

) wires for 24 Vdc Auxiliary Power.

Connection of one 14 AWG (2.5mm

2

) ESD drain (ground) wire. Required only when the 

control cable is not installed in grounded metal conduit.

The AV/Serial Interface station ships with a termination kit containing a LinkPower pigtail, Auxiliary 
Power pigtail, ground wire pigtail, spacers, and all required connectors for installation.

LinkPower 

pigtail

Ground 

pigtail

WAGO

Spacers

Auxiliary 

Power pigtail

Отзывы: