ETC Unison Echo DRd Скачать руководство пользователя страница 2

E T C   I n s t a l l a t i o n   G u i d e

Echo Network Termination Kit

Echo  Network  Termination  Kit

Page 2 of 2

Electronic Theatre Controls, Inc.

Step 5:

If the Category 5 cable running to the enclosure does not have a female RJ45 connector, 
reference the included 

Ethernet Cat5 Termination Kit Setup Guide 

to terminate 

Category 5 wiring to the provided Cat5 mounting box and connector.

• When installing, attach the Cat5 mounting box at the back of the enclosure, left of 

the neutral lug and at least one inch from any exposed copper.

Install the I/O card

Step 1:

Align the network termination card to the mounting studs at the lower left of the enclosure.

Step 2:

Use four of the included screws to secure the card to the enclosure.

Step 3:

Connect the included Ethernet patch cable from the previously installed Cat5 termination 
box to the receptacle on the network termination card.

Step 4:

Tie back and secure the Ethernet patch cable neatly inside the enclosure to ensure it does 
not interfere with module installation and DRd operation.

Step 5:

Replace the dimmer modules, Station Power Module and Architectural Control Processor 
into the slots they were previously removed.

Step 6:

Slide the module retention bar to the right and tighten the screws to secure it in place.

Step 7:

Supply power to the DRd enclosure.

Step 8:

Unless structural changes are being made to the existing system, no dimming or 
architectural re-configuration should be necessary. If the system is being modified, 
reference the related Architectural Control Processor Configuration and Programming 
Guide for configuration setup and operation information.

W A R N I N G :

Failure to properly space the mounting box from the exposed power lugs could 

result in damage to the DRd and its components and poses a serious safety 

risk.

W A R N I N G :

Never power up or operate the Unison DRd enclosure without all modules 

installed. Failure to comply exposes you to dangerously high voltages that may 

result in death by electrical shock.