11

TurboRay User Manual

Power

Input and Power Factor

VAC

AMPS

Hz

Watts

VA

PF

100

4.29

50

428

430

0.99

120

3.48

60

416

418

0.99

200

2.06

50

400

413

0.97

208

1.97

60

401

411

0.97

220

1.87

50

398

412

0.96

240

1.74

60

403

418

0.96

Connector Specification

A fixture power cord with powerCON TRUE1 input to bare end is provided. Install a suitable
connector to meet the installation requirements. See the following wire color code chart:

Wire Color Code
(EU)

Wire Color Code
(US)

Connection
type

Terminal

Green/Yellow

Green

Earth/Ground

Blue

White

Neutral

N

Brown

Black

Line (Live)

L

WARNING:

RISK OF ELECTRIC SHOCK! The powerCON TRUE1 is a

connector system consisting of the cable connector and the chassis
receptacle. A cable connector inserted the incorrect way could, in some
circumstances, lead to contact between live wires and the grounding contact
in the plug socket resulting in equipment malfunction and/or personal
injury.

Check the condition of your powerCON TRUE1 connector system (cable
connector and chassis receptacle) for clear signs of wear and tear.

Reference the

Neutrik Safety Notice powerCON TRUE1

for more safety

information.

Содержание TURBO RAY

Страница 1: ...Mode Esc Hold for Automated Luminaire User Manual Version 1 0 Revision C...

Страница 2: ...rademarks and patents go to etcconnect com ip All other trademarks both marked and not marked are the property of their respective owners Information and specifications in this document are subject to...

Страница 3: ...tre La Modification Du Produit 2 Produktmodifikationswarnung 2 Avvertenza Sulla Modifica Del Prodotto 2 Advertencia De Modificati n Del Producto 2 Declaration of Conformity 3 Important Safety Informat...

Страница 4: ...ut and Universe 16 Configure the Fixture 17 Navigate the User Interface 17 DMX Address 17 Settings Menu 18 Set the Control Options 18 Set the Network Options 18 Set the Pan Tilt Options 19 Set the Dim...

Страница 5: ...View Temperatures 23 View DMX Monitor 23 View Software Version 23 View Device 23 Error Codes 24 Cleaning and Maintenance 27 Table of Contents iii...

Страница 6: ...dely try the High End Systems Inc website at highend com Additional technical resources are available on the support website support etcconnect com HES If you have additional questions that cannot be...

Страница 7: ...ischen und internationalen Sicherheithsvorschriften Ab nderungen dieses Produktes k nnen dessen Sicherheit beeintr chtigen und unter Umst nden gegen die diesbez glichen Sicherheitsnormen versto en Avv...

Страница 8: ...arms Lane Austin Texas 78758 USA Product Name Turbo Ray Product Options All We hereby declare that the above referenced product complies with the essential requirements of Council Directives 2014 30 E...

Страница 9: ...messages Note Notes are helpful hints and information that is supplemental to the main text CAUTION This statement indicates that while operating equipment surfaces may reach very high temperatures A...

Страница 10: ...com 2 1 Mode Esc Hold for 1 Primary radial diffusers 16 segments 2 User interface full color graphical display six button navigational controls 7 5 4 6 3 3 Tilt lock 4 Yoke handle 5 Pan lock 6 Input a...

Страница 11: ...wn are listed as centimeter inch Mode Esc Hold for 67 cm 26 4 in 41 4 cm 16 3 in 11 4 cm 4 5 in 66 3 cm 26 1 in 48 cm 18 9 in 47 cm 18 5 in 41 7 cm 16 4 in 29 7 cm 11 7 in 42 9 cm 16 9 in 24 3 cm 9 8...

Страница 12: ...densing Do not use this fixture with a damaged power lead cord set If the lead is damaged it must be replaced by a qualified technician with an equivalent type before use Contact your local authorized...

Страница 13: ...functions Do not permit other persons who are not qualified and familiar with its functions to operate the fixture Please use the original packaging if the fixture is to be transported ETC and High E...

Страница 14: ...fixtures are placed on the feet The operating temperature range for this fixture is 0 40 C Do not operate the fixture outside of this range Never stand directly below the installed fixture when mount...

Страница 15: ...t steps 1 through 3 for the second clamp and bracket 5 Attach the provided safety cable through the attachment point on the bottom of the fixture upper enclosure and secure to the trussing system or o...

Страница 16: ...e US Connection type Terminal Green Yellow Green Earth Ground Blue White Neutral N Brown Black Line Live L WARNING RISK OF ELECTRIC SHOCK The powerCON TRUE1 is a connector system consisting of the cab...

Страница 17: ...other end Terminate the cable ends as indicated in the pinout image below Connect DMX Cables to Fixture The following instructions are guidelines for connecting DMX to your fixture Your installation m...

Страница 18: ...nd sold separately Contact your local High End dealer for ordering information visit highend com about contact us to locate a High End dealer Set the DMX Start Address Give each fixture a unique DMX s...

Страница 19: ...DMX Control 14 LED Cell Layout LED modules are arranged according to the image below 2 1 3 4 Notice in the above image how the fixture head is oriented in relation to the pan and tilt locks...

Страница 20: ...ernet control source to one of the Ethernet ports on the first fixture in the Ethernet control run 2 Connect the first fixture to a second fixture by connecting a cable from the second Ethernet port o...

Страница 21: ...ress so that the correct fixture responds to the control signals This DMX start address is the channel number from which the fixture starts to listen to the digital control information sent out from t...

Страница 22: ...buttons 3 Press the Enter button to select a menu item 4 Modify the selection by pressing the up down left or right navigation buttons according to the selection 5 Press the Enter button to confirm a...

Страница 23: ...Look Wait and Fade Sets the control mode when DMX is not connected The default setting is Hold Last Look Protocol DMX Art Net Sets the control mode The default setting is DMX When Art Net is selected...

Страница 24: ...een manually moved outside of control You may want to turn Pan Tilt Feedback to the Off setting when working on a fixture so that you can move the pan and tilt without correction The default setting i...

Страница 25: ...nactivity Flip Automatic Flip Set the display orientation When set to Automatic the accelerometer in the fixture determines the orientation Use the Flip menu option to manually override the current or...

Страница 26: ...wheel Diffusion homes the primary radial diffuser Zoom homes the optics system Test Options Navigate Main Menu Home Test Test Run a self test program on features and attributes of the TurboRay fixtur...

Страница 27: ...et Enter Passcode This protected menu provides access to reset Fixture and LED hours As needed contact Technical Support at High End Systems for access See Contacting High End Systems on page 1 View E...

Страница 28: ...each of the fixture s channels parameters of the fixture Scroll the list to view all available parameters DMX data is not available when DMX is not connected View Software Version Navigate Main Menu...

Страница 29: ...motor has malfunctioned the motor driver circuit has malfunctioned Boot Diff This message displays after the reset of the fixture if the bootloader for one of the Boot Sectors does not match the copy...

Страница 30: ...the driver board power or data wire harness is disconnected or damaged Pan Encoder This message displays after the reset of the fixture if any of the following conditions exist the pan lock is engage...

Страница 31: ...t Sensor This message displays after the reset of the fixture if any of the following conditions exist the Hall sensor has malfunctioned the magnet for the Hall sensor is missing the motor or sensor w...

Страница 32: ...ended CAUTION The lenses and the output window in the TurboRay fixture are coated with a HazeFree lens coating technology patent pending that keeps the lenses and output window clear when the fixture...

Страница 33: ...Cleaning and Maintenance 28...

Страница 34: ...K n Holzkirchen DE n Hong Kong Web highend com n Support support etcconnect com HES 2019 Electronic Theatre Controls Inc n Product information and specifications subject to change ETC intends this doc...