
Troubleshooting and Maintenance
27
Update All Connected Fixtures
1. After you update the firmware on a fixture, verify that the fixture is not receiving
DMX/RDM before you proceed.
2. Press the Menu button (
) on the fixture, and then use the Intensity encoder to navigate
through the menu: Local Settings > Push Firmware.
3. When the screen prompts you to confirm, press the green encoder (for the OK icon
) to
continue. The updated firmware is copied to all connected fixtures, and the screens on
connected fixtures display a progress message ("Firmware RX
x
%").
Backup and Restore the Fixture Configuration
You can save the fixture settings to a USB drive and then apply those settings to another fixture.
You can also use the saved settings as a backup, and then apply the settings to the same fixture
to restore it to a previous state.
Back Up Fixture Settings
1. Insert the USB drive in the USB port on the rear of the fixture (see
).
2. Press the Menu button (
), and then use the Intensity encoder to navigate through the
menu: Local Settings > USB > Save All Settings.
3. The display shows the file name to be saved (for example, s4cfg00.xml). Press the green
encoder (for the Save icon
) to save the file to the USB drive.
The display returns to the USB screen when the process is complete.
4. Remove the USB drive from the USB port.
Apply (or Restore) Fixture Settings
1. Insert the USB drive that contains the fixture settings file (s4cfg
xx
.xml) in the USB port on
the rear of the fixture (see
).
2. Press the Menu button (
), and then use the Intensity encoder to navigate through the
menu: Local Settings > USB > Apply All Settings.
3. When the screen prompts you to select the fixture settings file, use the Intensity encoder
to navigate to the correct file and select it.
The display returns to the USB screen when the process is complete.
4. Remove the USB drive from the USB port.
Push Fixture Settings to All Connected Fixtures
1. Press the Menu button (
), and then use the Intensity encoder to navigate through the
menu: Local Settings > Push Settings.
2. When the screen prompts you to confirm, press the green encoder (for the OK icon
) to
continue. The settings are copied to all connected fixtures, and the screens on connected
fixtures display a confirmation message ("Config Received").