ETC Installation Guide

P-NSPS-D

Electrical

48 VDC DIN Rail Power Supply

Accepts 100-240 VAC, 50/60 Hz input, and provides 48 VDC to the P-NSPS-D.

Network Station Power Supply

Note:

This product is intended for use with a Listed and marked

SELV/LPS or Class 2 supply.

Accepts 48 VDC input (supplied by included 48 VDC DIN rail power supply).

Supports up to 63 Paradigm stations and sensors over LinkConnect (four
bus terminations available).

Ethernet RJ45 for connection to the Paradigm lighting network.

Wiring

48 VDC Power Supply

Input

Use copper wire only, 2.5 mm

2

- 1 mm

2

(14-18 AWG), rated to withstand

minimum 60°C (140°F).

Output

Use the ETC-supplied 48 VDC power pigtail (blue and black wire pair)
between the 48 VDC Power Supply voltage output terminals and
the P-NSPS-D. No other connections are supported.

Network Station Power Supply

Input

Use the ETC-supplied 48 VDC power pigtail (blue and black wire pair) with
the three-position pluggable connector between the 48 VDC Power Supply
and the P-NSPS-D VDC input.

Note:

ETC requires the installed P-NSPS-D be grounded. Connect an

additional wire from the ground terminal to the shared ground used
for the LinkConnect data runs.

LinkConnect

Connect up to up to four LinkConnect data runs to the provided
eight-position connector. LinkConnect is a bidirectional protocol that carries
data and power over one pair of wires. ETC recommends Belden 8471 Class 2
wire (or approved equal - see the ETC cable cross database

etcconnect.com/Support/Cable-Cross-Database

for alternatives). LinkConnect

is topology-free and polarity-independent; you may install the wires in any

P-NSPS-D

Page 2 of 8

ETC

Содержание P-NSPS-D

Страница 1: ...e LinkConnect station communication bus The Network Station Power Supply consists of two components that must be used together the DIN rail Network Station Power Supply that powers the station communi...

Страница 2: ...r Supply voltage output terminals and the P NSPS D No other connections are supported Network Station Power Supply Input Use the ETC supplied 48 VDC power pigtail blue and black wire pair with the thr...

Страница 3: ...comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is o...

Страница 4: ...D a Run up to four LinkConnect data runs Belden 8471 or equivalent to the P NSPS D Strip 7 mm 1 4 in from the ends of each b Terminate the data wire typically white from one wire pair to terminal A a...

Страница 5: ...ire into the L terminal and the neutral wire to the N terminal Secure each wire in place using a 3 mm slotted screwdriver Torque to 5 kgf cm 4 4 Lb in 7 Connect to the Paradigm control network by conn...

Страница 6: ...resent in the system will display on the Status screen and will automatically clear themselves if the condition is resolved Error Description Resolution name Lost This P NSPS D has lost communication...

Страница 7: ...ware Reference the Paradigm LightDesigner online help system for details Preferences Preferences for the Network Station Power Supply such as inactivity time are set in the LightDesigner configuration...

Страница 8: ...ng Connected green Connected with Errors red a partial connection with bad comms Lost red comms activity is no longer present Unconnected red no comms present Main Menu About Setup File Operations Set...

Отзывы: