background image

10

Irideon WLZ User Manual

7.

Use the canopy bolts to secure the
fixture to the mounting plate.

CAUTION:

Make sure

that the wiring is clear of
the mounting plate
before you secure the
fixture.

Canopy 
bolts

8.

Oval-shaped covers

Insert the oval-shaped covers into the
canopy enclosure to cover the canopy bolt
openings.

9. Restore power at the disconnect device.

Содержание Irideon FPZ

Страница 1: ...Irideon WLZ User Manual Version 1 0 1 Part Number 7192M1200 1 0 1 Rev G Released 2021 10 ...

Страница 2: ...rademarks and patents go to etcconnect com ip All other trademarks both marked and not marked are the property of their respective owners ETC intends this document whether printed or electronic to be provided in its entirety ...

Страница 3: ...t 5 Install Canopy Fixture 0 10 V and DALI Variants 11 Install Portable Fixture with C clamp 13 Install Portable Fixture on Unistrut Track 15 Connect Cables to Portable Fixture 15 Configuration 16 Set the DMX Address at the Fixture 16 Adjust the Local Intensity 18 Initial Power Up 19 Status LED 19 RDM Values 20 Focus and Setup 20 Adjust the Tilt 20 ...

Страница 4: ...Adjust the Field 20 Use the Barn Door Accessory 21 Use the Integrated Media Holder 21 Cleaning 23 ii Irideon WLZ User Manual ...

Страница 5: ...ystem Portable Includes a miniature C clamp and yoke mounted driver and has a permanently installed power cord with 3 prong Edison connector Region specific connectors are available Contact ETC for available options Use L5 15 plugs on branch circuits with L5 15 receptacles only Canopy Available in three different control variants 0 10 V DALI DMX Canopy Portable Track mount Note The miniature C cla...

Страница 6: ...ot operate the fixture without a lens installed Do not use this fixture if a lens is deeply scratched or cracked You must replace a lens when it is damaged AVERTISSEMENT Prendre connaissance des avertissements de sécurité suivants avant toute utilisation Ne pas installer le projecteur sur ou à côté d une surface inflammable Vérifiez que le porte accessoires est verrouillé avant de monter le projec...

Страница 7: ...ure must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations AVERTISSEMENT RISQUE DE DÉCHARGE ÉLÉCTRIQUE L alimentation doit étre éteinte avant d exécuter cette procédure Track Mount Fixture WARNING To reduce the risk of fire and electric shock use the track mount fixture only with the DataTrack EUTRAC track system AVE...

Страница 8: ...nesting into the track s groove 2 Rotate the locking mechanism to lock the adapter into place WARNING When using the circuit selection lock ensure that the selected circuit is a constant power circuit Dialing into a dimmable circuit may cause fixture damage that will void the ETC warranty 3 Use the circuit selection lock to select the circuit The desired circuit number should point toward the cent...

Страница 9: ...1 16 in back boxes CAUTION DMX control is a Class 2 circuit DMX wiring cannot be run through the same conduit as line voltage power supply conductors Separate the line voltage from the data side in the back box Install the voltage barrier provided by ETC Install the voltage barrier in the back box with the provided bolt see images at right showing a 4 in back box The voltage barrier blocks two or ...

Страница 10: ...T Installez la plaque de protection comme indiqué ci dessous pour les installations où l intérieur de la rosace de plafond pourrait être exposé après l installation avec uniquement la plaque de montage Par exemple installez la plaque de protection lors de l installation sur un boîtier arrière à montage en surface 2 Are you flush mounting the fixture or surface mounting the fixture Flush mounting C...

Страница 11: ... GRN W GRN BLU W BLU If using Category 5 a See the Cat5 Cable Preparation for IDC Termination Setup Guide for instructions to prepare and terminate Category 5 for DMX RDM input cable to the insulation displacement connector b Install the IDC connector with wires terminated to the DMX RDM Input receptacle on the termination board 4 Optionally terminate DMX RDM thru to the next device in the DMX dat...

Страница 12: ...ting Plate and Complete the Wiring DMX Variant 1 Cover plate if needed for surface mounting Mounting plate Mounting plate bolts Canopy bolts Secure the mounting plate or the combination of mounting plate and cover plate for surface mounting to the installed back box positioning the plate so that the power side and data side are separated by the voltage barrier in the back box See Install the Volta...

Страница 13: ...ure using the three addressing dials in the canopy See Set the DMX Address at the Fixture on page 16 4 Connect the pre wired DMX connector on the fixture to the mated connector on the mounting plate shown below 5 Terminate DMX RDM data signal for the last DMX RDM device in the data run by setting the termination switch to ON to the right as shown below All other devices in the data run should reta...

Страница 14: ...he mounting plate CAUTION Make sure that the wiring is clear of the mounting plate before you secure the fixture Canopy bolts 8 Oval shaped covers Insert the oval shaped covers into the canopy enclosure to cover the canopy bolt openings 9 Restore power at the disconnect device ...

Страница 15: ...ior of the canopy enclosure could be exposed after installation with only the mounting plate For example install the cover plate when installing to a surface mount back box AVERTISSEMENT Installez la plaque de protection comme indiqué ci dessous pour les installations où l intérieur de la rosace de plafond pourrait être exposé après l installation avec uniquement la plaque de montage Par exemple i...

Страница 16: ... V and DALI variants Canopy bolt hole 3 3 For this structure secure mounting plate using 4 11 16 in back box Large oval slots see 1 at left 4 in back box Small oval slots see 2 at left Mud ring and round box Circular slots see 3 at left 3 Hook Use the hook in the canopy enclosure to hang the fixture from the mounting plate while you complete the fixture wiring 4 Connect the building ground wire to...

Страница 17: ...canopy enclosure to cover the canopy bolt openings Oval shaped covers 9 Restore power at the disconnect device Install Portable Fixture with C clamp The C clamp attaches the fixture to the mounting pipe and allows you to adjust the position of the fixture once it is mounted The C clamp will fit a 3 4 in to 2 in pipe Two different length pipe bolts are provided to accommodate different pipe sizes N...

Страница 18: ... to secure the fixture to larger mounting pipes If necessary exchange the standard pipe bolt for the longer pipe bolt included to secure the fixture to smaller mounting pipes Detail view of washers C clamp Spacer Washers Yoke bolt Yoke bolt 4 Loosen the C clamp yoke bolt and rotate the yoke to the desired position CAUTION Tighten the C clamp pipe bolt to about 18 in lb approximately finger tight p...

Страница 19: ...r data thru in either position as needed To order RJ45 to socket XLR adapter use part number W6538 To order RJ45 to plug XLR adapter use part number W6539 2 Connect the fixture to the power source Note The Irideon WLZ is not self terminating You must terminate the last fixture in line with a 120 Ohm resistor Please contact your ETC customer service representative to purchase part number N4086 No m...

Страница 20: ... that you set regardless of whether you set it via RDM or locally on the fixture There are three addressing dials on the track adapter track mounted fixture in the canopy canopy fixture or on the driver box portable fixture To set the DMX address use a small flatblade screwdriver to move the arrow to the desired address number DMX addresses must be set between 1 and 512 Each fixture must be consid...

Страница 21: ... 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 1 S 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 10 S 100 S 10 S 100 S Track mount Portable Local intensity control knob Status LED and DMX addressing dials Canopy mounting plate removed In these addressing examples the fixture is addressed to 503 ...

Страница 22: ...ation in Set the DMX Address at the Fixture on page 16 On the canopy fixture DMX variant only the local intensity adjustment control is located on the side of the canopy next to the status LED To adjust the local intensity knob on the canopy fixture you will need a small flatblade screwdriver jeweler s screwdriver You can adjust the local intensity with or without DMX being present When DMX is not...

Страница 23: ...ixture Apply power and dim the fixture using a 0 10 V controller Note The 0 10 V driver conforms to IEC 60929 Annex E Of the 0 10 V range use 0 1 V to set the minimum level and use 1 10 V for continuous dimming Canopy DALI Fixture Use a DALI configuration and commissioning tool to configure the DALI address of the fixture Status LED The status LED indicates the DMX status When DMX is present the L...

Страница 24: ... 2 kHz 1 High 25 kHz Focus and Setup Yoke locking knob Adjust the Tilt 1 Loosen but do not remove the yoke locking knob 2 Tilt the fixture to the desired angle 3 Tighten the yoke locking knob Field angle markers Adjust the Field Rotate the back of the fixture body to adjust the field between wide and narrow see image at left The field angle markers on the side of the fixture indicate the field ang...

Страница 25: ...o avoid unnecessary stress on the DataTrack adaptor C clamp or canopy Use the Integrated Media Holder The Irideon WLZ comes equipped with an integrated media holder which is a metal frame used to hold color media often referred to as gel or diffusion in front of the lens The media holder is equipped with a magnetic retaining clip that prevents the media from falling out The integrated media holder...

Страница 26: ...dia holder with the inset on the front casting Integrated media holder Dichroic glass Magnets Install Dichroic Glass The integrated media holder accommodates 1 75 mm thickness dichroic glass 1 Release the magnetic retaining clip by gently pushing it up 2 Place the dichroic glass into the groove 3 Replace the media holder by aligning the tab at the top of the media holder with the inset on the fron...

Страница 27: ...grated media holder Four bolts Front casting Glass lens CE version only Rubber ring Lens 1 Remove the integrated media holder 2 Use a Phillips screwdriver to remove the four bolts from the front of the fixture 3 Remove the front casting 4 Remove the lens rubber ring and glass lens CE version only 5 Remove dust with a blast of oil free air or wipe with a clean lint free cloth 6 Replace the lens rub...

Страница 28: ...NY Orlando FL Los Angeles CA Austin TX Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2021 Electronic Theatre Controls Inc Trademark and patent info etcconnect com ip Product information and specifications subject to change ETC intends this document to be provided in its entirety 7192M1200 1 0 1 Rev G Released 2021 10 ...

Отзывы: