13
BluesSystem Installation Manual
Power Supplies
BluesSystem Power Supplies are available in a One-Zone and a Six-Zone variant and provide
low voltage 24 or 36 VDC power to connected BlueBeam and BlueDome lighting fixtures.
Control input terminations are made inside of the power supply for the One-Zone and Six-
Zone wall mounted versions and are continued to the lighting fixtures.
Supplies
The following supplies are required, but not provided, for installation.
• Conduit and conduit fittings.
• Phillips head screw driver.
• Four each mounting bolts or screws and wall anchors as needed. Mounting hardware must hold
at least 2.6 lbs
for the one zone power supply and 8.5lbs for the six zone wall-mounted power
supply.
Wiring Requirements
Power
• Terminals accept 12 to 22 AWG
• max 0.5 Nm screw tightening torque
• wire strip length 7 to 7.5 mm
Control
WARNING:
A system without an accessible power disconnect device cannot be
serviced or operated safely. Follow all local codes and restrictions.
Model
Description
Notes
BS-PS1-W-S
Switched Power Supply
Supports a maximum of 10 fixtures.
BS-PS1-W-D
DMX Power Supply
Supports a maximum of 10 fixtures.
BS-PS6-W
6 Zone Power Supply,
Wall Mount
Each zone supports a maximum of ten fixtures.
The 6 Zone Power Supply supports up to 60 fixtures
maximum.
BS-PS6-R
6 Zone Power Supply,
Rack Mount
Control
Type
Wire Specification
Notes
DMX
Belden 9729 (or approved equal)
A 120 ohm resistor is required (not
provided) to terminate the last DMX
device in a control run.
Switched
12 to 30 AWG
0-10V
12 to 30 AWG