Reserved for future use

This test mode does nothing, returns to normal operation if selected. 

DEBUG: Test Button Pad

This test mode blinks the LEDs when button presses are detected.  No transmissions 

occur during transmissions. Button test mode will timeout after 180s and reboot the 

unit.  (Button activity does not reset the timeout counter.)

DEBUG: Transmit TCM APP Version

 

A single SIGNAL telegram (RORG 0xD with message identifier byte (MID) set to 0x07) 

is transmitted with the APP version of the TCM515U.

Error Codes

On p

ower up (battery newly inserted) a weak battery will cause the red LED to blink 

~ every half second.
When a low battery state has been detected during normal operation, the battery 

status is blinked about once per minute (64 s). A single red blink indicates the last 

measured battery voltage is between 2.0V and 2.2 V.  A triple red blink indicates the 

battery voltage is critically low (less than 2.0V).
A stuck button will cause the red LED to blink ~ every 5 seconds.

Equipment Profiles

EEP: F6-02-02 

Light Control - ON, OFF, Dimming

Accessories

PTM365BP1* - Single gang barrier plate for switches 
PTM365BP2*  - Dual gang barrier plate for switches

 * Available in White or Gray

FCC Part 15.231 - Remote Control Transmitters

Devices equipped with 902 MHz radio:

 

Contains FCC ID: SZV-TCM515U

 

Contains IC: 5713A-TCM515U
The  enclosed  device  complies  with  Part  15  of  the  FCC  Rules. 

 

Operation is subject to the

  following  two  conditions:

           

(I.)  this  device  may  not  cause  harmful  interference  an

(ii.) this device must accept any interference received, including 

interference that may cause undesired operation.

IC RSS-210

Barrier Plate Kit Certification

UL Standard 514D 
CSA Standard C22.2 # 42-1-13

               For more information on Echoflex Solutions, scan the QR code:

3060167

Copyright 2019-2020  Echoflex Solutions, Inc. Specifications subject to change without notice.

Echoflex Solutions

38924 Queens Way, Unit #1, Squamish, BC, V8B 0K8, Canada

  

n

  

+1 778-733-0111

echoflexsolutions.com

  

n

  

 8DC-5860-1.4

 

n

  

Document Part # 8188M21-5860-1 Rev E 

 

n

  

05/20

Содержание Echoflex MBI-2 Series

Страница 1: ...e MBI uses 2 buttons for On OFF operation The ON button has a light bulb icon with light rays to indicate ON The OFF button has a light bulb icon without rays indicating OFF The buttons provide both switching and dimming functionality A quick press of the button provides switching a press and hold will dim lights up ON button and down OFF button when linked to an Echoflex dimming controller A doub...

Страница 2: ... to an Echoflex Controller The linking process requires the controller or receiver to be mounted powered and within range of the station to be linked Each receiver can support up to 20 30 switch stations depending on receiver model 1 Activate LEARN or LINK mode at the receiver if necessary refer to the manufacturers documentation 2 For each pair of ON OFF buttons press the ON button three times in...

Страница 3: ...indicated by a light chase sequence green yellow red repeated three times A weak battery will cause a repeating red blink roughly every half second A stuck button will cause a repeating red blink roughly every 5 seconds Range Confirmation Provides visual feedback of the MBI s signal strength received by a linked Echoflex controller i Note Disable all repeaters in range The station should only be l...

Страница 4: ...s than 2 0V A stuck button will cause the red LED to blink every 5 seconds Equipment Profiles EEP F6 02 02 Light Control ON OFF Dimming Accessories PTM365BP1 Single gang barrier plate for switches PTM365BP2 Dual gang barrier plate for switches Available in White or Gray FCC Part 15 231 Remote Control Transmitters Devices equipped with 902 MHz radio Contains FCC ID SZV TCM515U Contains IC 5713A TCM...

Отзывы: