Echo Preset Station Installation

Echo  Preset  Station

 Page 3 of 6

ETC, Inc.

Connect the Wiring

Step 4:

Terminate and connect the station wiring.

a:

Locate the data pigtail and two WAGO LeverLock connectors 
found in the termination kit.

b:

Strip 3/8” (9-10mm) from the 
ends of each wire (both pigtail 
and installed data wire).

c:

Open the terminal levers on 
the WAGO connector and 
insert the Belden 8471 black 
(-) lead wire and the black (-) 
lead from the pigtail into the 
terminals.

d:

Close the levers onto the 
wires, securing the 
connection between the two.

e:

Repeat this process for the Belden 8471 white (+) wire and 
remaining white (+) pigtail wire using another WAGO connector.

f:

Attach the connector onto the 
preset station data connector.

Step 5:

Terminate the ESD drain (ground) 
wire.

a:

Locate the ground pigtail and one 
WAGO LeverLock connector from 
the termination kit.

b:

Strip 3/8” (9-10mm) from the end 
of the ground wire and ground 
pigtail.

c:

Open the terminal levers on the 
connector and insert the installed 
(typically green/yellow) ESD drain 
(ground) wire and the green/yellow lead from the pigtail into the 
terminals.

d:

Close the levers onto the wires, securing the connection between 
the two.

Topology of a single 

station installation

Topology of multiple 

stations installed in 

series

Installed control wire

Pigtail wire

Installed control wire
Installed wire to next station
Pigtail wire

Station power 

pigtail

Ground

pigtail

WAGO

Ground 

spade

Data 

connector