12
CEM3 User Manual
Test
Field
Description
Set Local Levels
Set levels for outputs from this rack only. This will present a table-style view
of the outputs in this rack and allow setting and releasing of levels. To set
levels:
•
Select a circuit by numeric entry or scrolling with the wheel
•
To select a range of circuits, use [thru] and [and].
- Press [Last/A] or [Next/B] on the keypad to set a level for the A or B
side of dimmer doubled circuits. See example below.
•
Press [at].
•
Use numeric entry or scroll to select a level. 0–100 is the valid range.
100 will display as "FL".
•
Press [Enter]. The selected circuits will be set to the specified level or
released if you did not enter a level.
Set System Levels
Set levels for chosen circuits in a space. See
on the next page. If
necessary, double press [Back] to clear the command line during any of the
following steps.
1: Use the keypad to enter a circuit number between 1 and 99999.
2: Press [and] to enter multiple circuits or press [thru] to enter a range of
circuits.
• Press [Last/A] or [Next/B] on the keypad to set a level for the A or B
side of dimmer doubled circuits. See example below.
3: Press [at] or [Enter]. The command line ends with "at".
4: Use the keypad or scroll wheel to enter a level if desired. 0–100 is the
valid range. 100 will display as "FL".
5: Press [Enter]. The selected circuits will be set to the specified level or
released if you did not enter a level. The command line ends with "*".
6: If you selected a single circuit, press [Next] or [Last] on the keypad to
increment or decrement the circuit number to set the level of another
circuit, if desired.
Dimmer Check
Quickly run through all lugs or all circuits in a space to test their output at a
given percentage.
Release Systm Lvls
Release any active levels for a given space at once.
Presets
Record or play back presets. See
Sequences
Record or play back sequences. See
Recording and Playing Sequences
Release All Arch
Release all architectural control such as presets, sequences, and set zone
levels.
Record Rig Check
Record a rig check preset to facilitate AF reporting. Rig Check features are
only available if the rack property AF Enabled is set to Yes. See
for more information.
Run Rig Check
Run a rig check preset. You will be notified of any load inconsistencies
found during the rig check.
Clear Rig Check
Clear the recorded rig check from all racks for a given space.