ArcSystem Pro Multi-Cell RDM

Installation Guide

Part Number: 7490M2160 Rev: C

Released: 2020-09

Содержание ArcSystem Pro Multi-Cell RDM

Страница 1: ...ArcSystem Pro Multi Cell RDM Installation Guide Part Number 7490M2160 Rev C Released 2020 09...

Страница 2: ...ademarks and patents go to etcconnect com ip All other trademarks both marked and not marked are the property of their respective owners ETC intends this document whether printed or electronic to be p...

Страница 3: ...7 Installing 100 240 V Multi Cell Luminaires 8 DMX 8 Installation Procedure 8 Installing 100 240 V Four Cell Round Luminaires 9 Installing to Threaded Rod 9 Installing 100 277 V Multi Cell Luminaires...

Страница 4: ...Sense Input 26 Complete Installation 27 Installing a 100 277 V Emergency Four Cell Pendant 27 Prepare the Cylinder and Stem 28 Prepare the Back Box 28 Terminate Building Wiring to the Canopy 29 Instal...

Страница 5: ...Compliance 37 Table of Contents iii...

Страница 6: ...iv ArcSystem Pro Multi Cell Installation Guide...

Страница 7: ...l luminaires and D1 D2 or D4 Series Drivers see the ArcSystem Pro D1 and D2 Series Drivers Installation Guide or the ArcSystem Pro D4 Series Drivers Installation Guide at etcconnect com ArcSystem All...

Страница 8: ...on number if you have called in previously Americas United Kingdom ETC Inc ETC Ltd Technical Services Department Technical Services Department 3031 Pleasant View Road 26 28 Victoria Industrial Estate...

Страница 9: ...READ AND FOLLOW ALL SAFETY INSTRUCTIONS Do not use outdoors Do not let power supply cords touch hot surfaces Do not mount near gas or electric heaters Equipment should be mounted in locations and at h...

Страница 10: ...5 15 connectors four cell round North America only 100 240 V hard wired cables with bare ends four cell round Europe linear and square yoke mount round and pendant options beam angle options 19 24 37...

Страница 11: ...rd wired to emergency certified drivers to be considered for UL924 certification Note The number of designated emergency lamps and their height is the responsibility of the specifier and installer in...

Страница 12: ...t mix 120 V and 277 V between the sense and emergency feeds AVERTISSEMENT Ne pas inverser les alimentations 120 V et 277 V entre les alimentations de d tection et de secours WARNING Sense normal and M...

Страница 13: ...ollow appropriate Lockout Tagout procedures as mandated by NFPA 70E It is important to note that electrical equipment such as breaker panels can present an arc flash hazard if improperly serviced This...

Страница 14: ...inout Information Pin Description 1 Data 2 Data 7 8 ISO ground common Four cell square luminaire shown DMX In and Thru connections Power switch Power connection Installation Procedure 1 Attach a C cla...

Страница 15: ...two provided M4x16 flathead screws 1 shown to the right 2 Install the other piece of the nut B with the two provided M4x16 flathead screws 2 shown to the right 3 Attach the luminaire to installed thre...

Страница 16: ...onductor ArcSystem 100 277 V luminaires and drivers accept 100 277 VAC 50 60 Hz ETC recommends installing all wiring in grounded metal conduit Wire and Terminal Specifications Luminaire Type Terminal...

Страница 17: ...conduit entry for 1 2 in conduit C DMX in and thru 1 Make sure power is off at the main circuit breaker 2 Attach a C clamp or other mounting hardware not provided to the yoke of the luminaire 3 Attach...

Страница 18: ...412 See Installing 100 277 V Emergency Multi Cell Luminaires on page 24 for more information about wiring for emergency installations Factory Wire Colors Model Color Type North America green yellow g...

Страница 19: ...hrough conduit to a free position on the WAGO connector Note Line hot wire color varies based on voltage and region but is typically black brown orange or yellow c Lift up the orange clip insert the l...

Страница 20: ...d the stem that is shipped separately The canopy mounting plate installs onto a voltage separated junction box The canopy is supplied with WAGO connectors for convenient internal and external power co...

Страница 21: ...mbination DMX termination kit 1 not shown Two position WAGO ETC part number J4717 WAGO part number 221 412 2 for standard pendant 4 for emergency pendant installed on canopy mounting plate not shown F...

Страница 22: ...secure the ring terminal onto the ground stud 2 Install the plug on other wire harnesses onto the mating connectors on the cylinder a POWER IN Install the plug on the black and red two wire harness to...

Страница 23: ...tors through the parts below in this order a Gasket A illustrated to the right b Large ring terminal on the grounding harness B illustrated to the right c Large nut C illustrated to the right 3 Hand t...

Страница 24: ...ee position on the WAGO connector c Lift up the orange clip insert the ground wire and press the clip down onto the wire d Tug gently to make sure the wire is secure 3 Terminate neutral a Locate the W...

Страница 25: ...he control source through the back box to the canopy mounting plate a If using Belden 9729 a See the DMX Cable Preparation for Screw Termination Setup Guide for instructions to prepare and terminate B...

Страница 26: ...its through the slot on the mounting bracket C should fit through D in the illustration to the right If the stem grounding harness is not aligned as shown to the right loosen the large nut at the top...

Страница 27: ...tion correctly Terminate the pre stripped ends of the five wire Belden cable to the eight pin screw terminal plug item 7 in the illustration at 100 277 V Four Cell Pendant Components on page 15 1 Slid...

Страница 28: ...isted wire pair to the WAGOs inside the canopy See Installing a 100 277 V Emergency Four Cell Pendant on page 27 for more information on installing a Pro Four Cell Emergency Pendant Complete Canopy In...

Страница 29: ...rgency luminaires are supplied with hard wired power cables with NEMA 5 15 connectors for North America and bare ends for Europe and the rest of the world The cables are labeled near the strain relief...

Страница 30: ...ht cell luminaire A A A A C B C B C B C B D D D D A wiring compartment B conduit entry for 1 2 in conduit C DMX in and thru D knockout for 1 2 in conduit With the exception of power input terminations...

Страница 31: ...413 and four two position WAGO connectors ETC part number J4717 WAGO part number 221 412 Factory Wire Colors Model Color Type North America green yellow ground North America black line hot North Ameri...

Страница 32: ...cate the WAGO connector on the line hot wire black from the input labeled Maintained b Run a line hot wire through conduit to a free position on the WAGO connector Note Line hot wire color varies base...

Страница 33: ...ecure in their terminals 3 Tuck wiring inside the wiring compartment and replace the wiring compartment cover using the screws set aside previously 4 Rotate the luminaire so it is roughly focused to i...

Страница 34: ...rected for the standard Four Cell Pendant 1 Connect the Stem to the Cylinder on page 16 2 Wire the Cylinder on page 16 After completing the steps at the link above install the connector for the sense...

Страница 35: ...sense input on the canopy 1 See Electrical and Wiring Specification on page 10 for specification of wire and strip length Prepare wires accordingly 2 Terminate ground a Locate the WAGO connector on t...

Страница 36: ...Stem in the Canopy Connect the stem to the canopy as instructed in Hang the Stem in the Canopy on page 20 Terminate Wiring Inside the Canopy C H B A F G E D A Canopy cover grounding harness green yel...

Страница 37: ...Installing 100 277 V Emergency Multi Cell Luminaires 31 Complete Canopy Installation Complete canopy installation as instructed in Complete Canopy Installation on page 22...

Страница 38: ...reaker After the power up procedure the luminaire will light Note When commissioning a system installation check all ArcSystem Drivers and multi cell luminaires to ensure that the latest firmware is p...

Страница 39: ...7 Pro Four Cell Square 0x1208 Pro Four Cell Square Emergency 0x1308 Pro Four Cell Linear 0x1209 Pro Four Cell Linear Emergency 0x1309 Pro Eight Cell 0x120C Pro Eight Cell Emergency 0x130C Pro Four Cel...

Страница 40: ...Level that is lower than the Minimum Level Curve 0x0343 1 2 or 3 Set to 1 is the Default Tungsten Curve aka D04A Set to 2 is Linear Set to 3 is Square Law Curve Description 0x0344 Get returns an ASCII...

Страница 41: ...e installation maintenance cleaning or any other system modification could result in serious injury or death AVERTISSEMENT RISQUE DE MORT PAR D CHARGE LECTRIQUE N gliger de d brancher toutes les sourc...

Страница 42: ...ng can be used to blow through the vent holes and remove dust or other debris Dust buildup can cause overheating and premature shutdown All components can be cleaned using compressed oil free air as d...

Страница 43: ...e energize main feed to ArcSystem and follow appropriate Lockout Tagout procedures as mandated by NFPA 70E It is important to note that electrical equipment such as breaker panels can present an arc f...

Страница 44: ...683 Hong Kong 852 2799 1220 Paris FR 33 1 4243 3535 Web etcconnect com Support support etcconnect com Contact etcconnect com contactETC 2020 ETC Trademark and patent info etcconnect com ip Product inf...