Final Installation and Operation
33
Maintenance
WARNING:
RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all
power to the system before installation, maintenance, cleaning, or any
other system modification could result in serious injury or death.
AVERTISSEMENT :
RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE!
Négliger de débrancher toutes les sources d’alimentation du système avant
l’installation, l’entretien, le nettoyage ou toute autre modification du
système peut causer des blessures graves ou la mort.
De-energize main feed to ArcLamp and follow appropriate Lockout/Tagout
procedures as mandated by NFPA 70E. It is important to note that electrical
equipment such as the ArcLamp driver can present an arc flash hazard if
improperly serviced. This is due to the high amounts of short-circuit current
available on the electrical supply to this equipment. Any work must comply
with OSHA Safe Working Practices.
WARNING:
Circuits that are installed without an accessible power
disconnect device cannot be serviced or operated safely.
AVERTISSEMENT :
Il est imprudent d'utiliser ou de réparer les circuits
installés sans qu'un dispositif de déconnexion de l'alimentation ne soit
accessible.
ArcLamps
Inspect the ArcLamps for dust. As needed, use a lint-free cloth to wipe the lamps.
ArcLamp Driver
•
Inspect the all mounting hardware for secure installation. As needed, replace worn or
damaged hardware.
•
Check for excessive dust or debris in the air flow vents around the ArcLamp Driver
enclosure. Clean the vents using compressed air or a soft lint-free cloth. Keeping the
components of the enclosure clean facilitates efficient cooling.
Note:
A can of compressed air or oil-free air from an air compressor, set at a low
setting, can be used to blow dust and debris from the vents on the ArcLamp Driver. Dust
buildup can cause overheating and premature failure of the system.
CAUTION:
Never spray liquids into the ArcLamp Driver and never spray
compressed air into an ArcLamp Driver that is powered up.