4

ENGLISH

In case of failure and/or malfunctioning of the device, switch it off and do not tamper with it. For any repairs, please contact our

service centres and request use of original spare parts. Failure to comply with the above can jeopardise the safety of the pump.

If you decide to no longer to use a device, it is recommended to make it inoperable by unplugging it from the mains.

Make sure it is switched off electrically (both polarities), disconnecting the conductors from the contact points of the mains by
opening the omnipolar switch with at least 3 mm between the contacts.

Appropriately eliminate any pressure in the peristaltic pumps and supply pipes, paying the utmost attention.

Eliminate all the liquid in the pinch tubes.

In case of any leaks in the hydraulic system of the pump (breakage of injection valve, filter, pipes), you must stop the pump,

depressurise the supply pipe and then proceed with maintenance operations using appropriate safety measures (gloves, goggles,
overalls, etc.).

D i s p e n s i n g h a r m f u l a n d / o r t o x i c l i q u i d s

The following rules, along with the instructions in this booklet, must be kept in mind to avoid personal harm or property damage

due to contact with harmful liquids or the intake of toxic fumes:

Always work as recommended by the manufacturer of the liquid being used.

Use appropriate personal protective equipment

Check that the hydraulic part of the pumps has no damage or breakage. Only use the device if in perfect working order.

Use tubes suited to the liquid and the operating conditions of the plant, inserting them, if necessary, into protective PVC pipes

Before deactivating the device, you must neutralise the hydraulic part with an appropriate reagent.

A s s e m b l i n g t h e p u m p

All metering pumps manufactured by us are usually supplied fully assembled. For further explanations, please consult the

attachment at the end of this manual where exploded drawings of the pumps and all parts with relative nomenclature are displayed in
order to have a complete picture of the equipment. These drawings are anyhow required to recognise the malfunctioning or defective
parts.

D i s a s s e m b l i n g t h e p u m p

You must always pay the utmost attention when disassembling the pump or anyhow before performing maintenance on it. We

recommend consulting the attached drawings and referring to the previous chapter

“RISKS”

before beginning any operation.

ETWIN SERIES METERING PUMP

G e n e r a l f e a t u r e s o f E Tw i n p u m p s

ETwin is an easy to use device, consisting of a pair of metering pumps (electromagnetic or peristaltic) and electronics capable of

measuring the chemical values of water in a swimming pool, such as pH, redox potential (mV) and chlorine concentration (in ppm).
These parameters can be controlled by dosing appropriate additives with the pumps supplied with eTwin. The materials eTwin is made
of are suited for dosing the most common products used in the swimming pool industry.

See the instructions for use supplied by the manufacturer of the chemicals for the selection and correct use of the

additives used in swimming pools.

Default settings

eTwin pH – RX

Set-point = 7.2pH; intervention: ACID

,

Set-point= 700mV; intervention: OXIDANT

eTwin Cl – pH

Set-point = 7.2pH; intervention: ACID, 1 ppm (scale 0 - 2 ppm); DIRECT intervention

eTwin 2 pH

Set-point = 7.2pH; intervention: ACID on both measurements

Содержание eTwin

Страница 1: ...E OPERATINGINSTRUCTIONS AND MAINTENANCE NOTICED INSTALLATION EMPLOI ET ENTRETIEN NORMAS DE INSTALACI N USO Y MANUTENCI N NORMAS DE INSTALA O USO E MANUTEN O IT UK FR ES PR eTwin March 2020 Edition GEB...

Страница 2: ......

Страница 3: ...Main features 5 Technical features of peristaltic version 6 Technical features of electromagnetic version 6 Materials in contact with additive in peristaltic version 6 Materials in contact with additi...

Страница 4: ...puts 19 Inputs 21 Timer 21 Alarms 23 mA output 25 Visualization of the probe mVs 25 Activation delay 26 pH priority 26 Temperature 26 PPM scale values 27 Clock 27 Password 28 Setting the language 29 R...

Страница 5: ...smust bemade within10 days ofarrival ofthe goods Whereas defective material within 30 days of receipt If the device is to be replaced it must be agreed upon with authorised personnel or the authorised...

Страница 6: ...g them if necessary into protective PVC pipes Before deactivating the device you must neutralise the hydraulic part with an appropriate reagent Assembling the pump All metering pumps manufactured by u...

Страница 7: ...s to their inlet outlet action Operating principle of electromagnetic pumps The metering pump operates by means of a PTFE Teflon diaphragm mounted on the piston of an electromagnet When the piston of...

Страница 8: ...W Injections pul 1 Pipe ODxID mm Height Width Depth eTwin 2 0 6 0 3 5 270 235 148 65 120 4 x 6 5 0 5 0 3 5 270 235 148 65 120 4 x 6 Materials in contact with additive in peristaltic version Pinch tube...

Страница 9: ...always enabled ACTIVATION DELAY It defines a time starting from switch on during which the device does not dose or measure When switched on a countdown is displayed indicating the time remaining unti...

Страница 10: ...ig 1 Views and dimensions peristaltic version Fig 2 Views and dimensions electromagnetic version Fig 4 Drilling support bracket Position the pump as in the figure considering that it must be secured b...

Страница 11: ...the sides of the cover with a flat headed 5mm at least screwdriver to reach the terminal board The terminal board consists of spring terminals for quick coupling of the wires Press the square slotted...

Страница 12: ...owing table shows the allocations of measuring channels 1 and 2 according to your eTwin version Measurement Version pH Rx Chlorine pH pH pH Measurement 1 pH Chlorine pH Measurement 2 Rx pH pH Table 1...

Страница 13: ...ur of the device unchanged the jumpers can be removed and switched to NC normally closed For the operating modes see the chapter on settings of the external inputs DESCRIPTION OF THE SCREEN Access to...

Страница 14: ...pressing the key The PRIMING function can be activated even if the pump is protected by PASSWORD SET POINT CONFIGURATION MENU Setting pH Rx Chlorine parameters The following tables show the sequence o...

Страница 15: ...asing the pH value the pump doses with measures of pH lower than the set point Rx If an oxidant product is used e g sodium hypochlorite the pump intervening with oxidant doses by mV values lower than...

Страница 16: ...er hand the pH probe must be connected to the second channel To get started connect the probe to the instrument as indicated in Fig 10 o 10 1 depending on the instrument in possession 1 power cord 2 e...

Страница 17: ...st be calibrated Either electrodes made of glass or plastic can be used The instructions for calibrating the probe apply to all eTwin device models and versions During the calibration the pH Rx and PP...

Страница 18: ...possibleresults are 100 75 50 25 CALIBRATION ERROR The last parameter means that the calibration was not successful due to an error in the procedure or that the probe is to be considered no longer us...

Страница 19: ...e electrically and wait for it to polarise approximately 2 hours see the relative probe manual Install an active carbon filter upstream of the plant and have water flow in it for about 30 minutes Wait...

Страница 20: ...nu which can be accessed Since it is a circular menu the device stores the last item selected before exiting by pressing You may scroll the different items using the and keys and then selecting the co...

Страница 21: ...the connection of the relays By default RELAY 1 is associated to Pump_1 RELAY 2 to Pump_2 and RELAY 3 to the TIMER The timer of the relay function is independent from the timer function described in...

Страница 22: ...20 ENGLISH Similar procedures can be followed to configure the outputs connected to RELAY 2 and RELAY 3...

Страница 23: ...settings the device can operate without connecting external sensors Eliminate these jumpers when the consents are used Otherwise check whether the overdosage alarm triggers with a time compatible wit...

Страница 24: ...ecommended to disable it or to reset the parameters Before setting the timer correctly set the current date and time See the relative paragraph DAILY TIMER setting It is possible to set up to 4 daily...

Страница 25: ...quid to be dosed in the tank is finished The instrument blocks signalling the alarm status Connect the level probe to the terminal board of the instrument and introduce it in the tank containing the a...

Страница 26: ...n PAUSE and then press ESC for about 5 sec The same procedure must be repeated on measurement 2 P2 Redox Overdosage alarm An alarm could be triggered if the set point values are not reached after a ce...

Страница 27: ...epeated if ON THE OTHER HAND it is decided to associate the mA OUTPUT to measurement 2 Rx or pH depending on the models The value of the mA output can be viewed in RUN mode by pressing and go back to...

Страница 28: ...e following functional modes can be selected MANUAL the value the user sets in the configuration menu represents the parameter of reference for compensation of the pH value default setting 25 C AUTOMA...

Страница 29: ...r deactivation of the device This is why the electronic device is equipped with a clock and calendar the following settings can be made CLOCK hh mm Day Hours Minutes MON TUE WED THU FRI SAT SUN DATE D...

Страница 30: ...TION SETPOINT SETTINGS STAND BY The password has 4 numbers and is unique By default the passport is disabled on all the sections The following are the indications for setting the functional parameters...

Страница 31: ...the gaskets Perform these checks more frequently for particularly aggressive liquids Especially check concentration of the additive in the plant This concentration could be reduced due to wear of the...

Страница 32: ...tube FOR THE ELECTROMAGNETIC VERSION 1 Diaphragm worn replace it 2 Burnt fuse on magnet replace it check the resistance of the magnet 3 Electromagnet burnt replace it FOR ALL VERSIONS 1 Check the stat...

Страница 33: ...ENGLISH 31 DRAWINGS Peristaltic and Electromagnetic Pump Exploded Drawings PERISTALTIC ELECTROMAGNETIC...

Страница 34: ...OPERCHIO POSTERIORE BACK COVER LOCK SCREW DVI 00057 01 DVI 00057 01 7 SCHEDA COMANDI ELECTRONIC COMMANDS BOARD RPB 00220 21 RPB 00220 22 8 CONNETTORE SCHEDE BOARD S CONNECTOR DCN 00061 01 DCN 00061 01...

Страница 35: ......

Страница 36: ...1 34 48 77 15 Fax 33 0 1 78 76 73 95 RUSSIAN FEDERATION DOSING SYSTEMS 3 rd Mytishenskaya 16 2 129626 Moscow RUSSIA Phone 7 495 787 1459 Fax 7 495 787 1459 UKRAINE ETATRON UKRAINEltd Soborna Street 44...

Отзывы: