background image

 

 

 

 

 

Risks 

After  removing  the  packaging,  check  the  pump  for  any  damage.  If  in  doubt  do  not  use  the  pump  and  contact  qualified 

personnel.  All  packaging  elements  (such  as  plastic  bags,  polystyrene,  etc.)  must  be  kept  out  of  the  reach  of  children  as  the 

material is potentially dangerous. 

Before  connecting  the  pump,  check  that  the  data  on  the  nameplate  corresponds  to  the  local  voltage  ratings.  The  data  is 

available on the adhesive nameplate on the pump. 

The electrical plant must be comply with any local regulations in the country where the pump is installed. 

Observe some fundamental rules when using any type of electrical equipment, in particular: 

 

Do not touch the equipment with wet or damp hands or feet; 

 

Do not operate the pump without shoes (e.g. swimming pools); 

 

Do not leave the pump exposed to atmospheric agents (rain, sun, etc.) 

 

Do not allow the pump to be used by children or unskilled individuals without supervision. 

In case of faults and/or bad pump operation, turn off the pump and do not tamper. For any necessary repairs contact our 

specialized  technical  assistance  centers  and  insist  on  the  use  of  original  spare  parts.  Any  lack  of  respect  to  the  above  may 
compromise pump safety. 

If the user decides to make no further use of an installed pump, it is recommended to render the pump in operative and 

disconnect it from the power supply. 

If any liquid losses are present in the hydraulic system (due to O-ring seals, valves or piping breakages), stop the pump by 

releasing pressure in the discharge tube and then proceed with maintenance operations using adequate safety measures (gloves, 
goggles, overalls, etc.). 

Assembly 

All the pumps we produce are normally supplied fully assembled. For better clarification, consult the appendix at the end of 

this  manual  where  exploded  assembly  drawings  and  views  of  the  pumps  are  available  together with  all  components  and  their 
nomenclature, for the user to have complete details of the pump components. These drawings are indispensable when searching 

for malfunctioning or defective parts. Other drawings refer to  hydraulic parts (pump header and valves) and are shown for the 
same reasons in the appendix at the end of the booklet. 

Dismantlement 

To dismantle the pump or before performing pump maintenance, proceed as follows: 

 

Make sure the pump is electrically deactivated (both poles) by disconnecting the conductors from the power supply 

using the omnipolar switch which must have a minimum distance of 3mm between its contacts (Fig.3). 

 

Relieve the pressure in the pump head and the discharge tube in the most adequate way possible (be very careful 

during this operation). 

 

Drain the liquid present in the pump head by disassembling and reassembling the pump head using the four fixing 

screws, tightening torque 180÷200 N*cm (Appendix 1). 

Please pay particolar attention to this last point and we recommend the user to consult the enclosed drawings and chapter 

RISKS

” before starting any operations. 

Warranty 

2 years (normal wear on parts is excluded, i.e.: valves, fittings, piping ring nuts, piping, filter and injection valve). Improper 

equipment use invalidates the warranty. The warranty is intended ex works or at an authorized distributor. 

 

 

 

 

Содержание eOneMa

Страница 1: ...1...

Страница 2: ...dimensions 7 Material in contact with the additive 7 INSTALLATION 8 Introduction 8 Pump installation 8 Electrical scheme 8 Tubes connection 9 Typical installation 10 Accessories 11 REGULATIONS FOR SU...

Страница 3: ...in this manual FORBIDDEN Before safety information it highlights an operation not to be performed ATTENTION Before a very important notes regarding health protection for the exposed personnel or regar...

Страница 4: ...p in his possession and its correct use The manufacturer cannot be considered responsible for any damage derived from improper erroneous and unreasonable use Shipping and handling Shipping must be per...

Страница 5: ...the discharge tube and then proceed with maintenance operations using adequate safety measures gloves goggles overalls etc Assembly All the pumps we produce are normally supplied fully assembled For...

Страница 6: ...s and UV rays Power supply extended range 90 260 Volt 50 60 Hz IP65 protection level Environmental conditions closed environment altitude up to 2000 m ambient temperature from 5 C to 40 C maximum rela...

Страница 7: ...h water at temperature of 20 C Overall dimensions Fig 1 Dimensions in mm Plate for wall mounting Material in contact with the additive In the standard configuration the pumps of the eOne series are su...

Страница 8: ...d state before starting up the pump Locate the pump as shown in fig 2 taking into account that it can be located over or under the liquid level within a maximum difference of 1 5 meters The injection...

Страница 9: ...through ring nut 2 and bush 3 3 Press the hose end 1 onto the conic adapter of the nozzle 4 4 Place the nozzle 4 onto the nipple 5 5 Tighten the ring nut 2 onto the nipple 5 Fig 4 Tubes connection To...

Страница 10: ...10 Fig 5 Priming sequence Typical installation A Main pipeline B Injection valve C Backpressure valve D Pressure gauge E Relief valve F Power supply plug G Chemical tank H Foot filter I Level probe...

Страница 11: ...lene semi rigid white discharge hose length 2m n 1 3 8 BSP injection valve n 1 foot filter n 1 instruction manual REGULATIONS FOR SULPHURIC ACID ADDITIVE MAX 50 In this case it is necessary to take in...

Страница 12: ...e section the pump stop dosing and the red LED lights up UNDER LOAD and OVER LOAD functions The innovative HRS technology has allowed to create a range of metering pumps capable of detecting pressure...

Страница 13: ...default Level alarm and 1 1 signal input The pump is supplied with a connector for a level switch supplied on request When the height of the liquid in the product tank is lower than a predetermined mi...

Страница 14: ...he additive from the tube Again if the casing is in contact with the additive must be cleaned Warning when the power supply is deactivated the pump may emit one or more pulses so before you disconnect...

Страница 15: ...X 1 PUMP DRAWINGS 1 pump head screws to tighten the four screws use a dynamometer screwdriver set to a tightening torque of 180 200 Nxcm using a hexagonal insert of 2 5 mm 1 ELECTROMAGNET 2 PUMP HEAD...

Страница 16: ...MORSETTI APPENDIX 2 EXPLODED VIEWS 1 Plastic casing 2 Plastic cover 3 Pump head 4 Electromagnet 5 Pump gasket 6 PC board 7 Knob basket 8 Adjustment knob 9 Flange 10 Diaphragm 11 Pump head basket 12 p...

Страница 17: ...106 5 Body filter 6 Ceramic ball 7 O ring 3030 8 O ring 3081 9 Valve seat 10 Filterinig basket 1 Ring nut 2 Bush 3 Nozze 4 O ring 106 5 Injection valve nipple 6 Adapter 7 O ring 3024 3030 8 Ceramic b...

Страница 18: ...18...

Отзывы: