![Etatron DLX-pH/M SERIES Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/etatron/dlx-ph-m-series/dlx-ph-m-series_operating-instructions-and-maintenance-manual_2431281014.webp)
•
29
•
ENGLISH
Fig. 15
7.0 - MICROCONTROLLED METERING PUMP WITH Rx CONTROLLER
This unit is dosing pump with integral Rx controller designed to measure, control and regulate the Rx value. The
pump works on an ON/OFF system controlled by a microcontroller to stop dosing once the Rx value reaches set
point.
Measuring range: 0 ÷ 1000 mV (resolution 1 mV)
7.1 - PUMPS CONTROLS (Fig. 15)
1 - Increasing values button (RIGHT)
2 - Calibration button
3 - Decreasing values button (LEFT)
4 - Red LED "GAIN"
5 - Red LED "ZERO"
6 - Yellow LED level alarm
7 - Red LED injection pulse
8 - Green LED power supply
9 - LCD display
10 - Setpoint regulation button
11 - Function selection button
7.2 - TYPICAL INSTALLATION (Fig. 16)
A Injection
valve
B Power
supply
C Filter
E Electrode
I Chemical
tank
P Electrode
holder
V Process
tank
7.3 - ACCESSORIES
• 1 flexible PVC suction hose;
transparent crystal type, length 2 m;
• 1 semirigid polyethylene hose, white, length 2 m;
• 1 injection valve 3/8 BSP m;
• 1
filter;
• 1 instructions/operating booklet.
Fig. 16
DLX-Rx/M • DLXB-Rx/M
1
2
3
6
7
8
4
5
9
10
11