Applications

The XETK-S21.0 is an emulator probe for the Freescale MPC57xx and for the 
STMicroelectronics EM57xx microcontroller family. It is a typical serial XETK 
designed for use with the JTAG portion of the Nexus debug interface (IEEE/
ISTO 5001). 

Fig.

 

3

-

1

XETK-S21.0 

The XETK-S21.0 supports the standard full duplex 100Base-T Ethernet inter

-

face and can be connected directly or via ES51x/ES59x/ES600 modules to the 
PC. No additional ETAS modules are required for the access to the ECU. The 
XETK-S21.0 can be used for rapid prototyping applications (bypass) as well as 
for measurement and calibration applications.

NOTE

For supported MPC57xx microcontrollers, refer to chapter 7.1.3 on

 

page

 

34.

XETK-S21.0

XETK ECU interface connectors

12 pin ERNI plus 7 pin JST

Power supply for ED devices (VDDS

-

BRAM)

min. 1.25

 

V

SBRAM sense

Yes, on board or external sense

Pinless triggering

Yes

Timer triggering

Yes

Содержание XETK-S21.0

Страница 1: ...ETAS XETK S21 0 Emulator Probe for the JDP MPC57xx Microcontroller Family User Guide...

Страница 2: ...ngle license Using and copying is only allowed in concurrence with the specifications stipu lated in the contract Under no circumstances may any part of this document be copied reproduced transmitted...

Страница 3: ...nformity 12 2 7 UKCA Conformity 12 2 8 RoHS Conformity 12 2 9 Declarable Substances 13 2 10 Use of Open Source Software 13 3 Introduction 14 3 1 Applications 14 3 2 Features 15 4 Hardware Description...

Страница 4: ...JTAG Timing Characteristics 39 7 8 1 JTAG Timing Diagram 39 7 8 2 JTAG Timing Parameters 40 7 8 3 Debugger Arbitration Timing Diagram 40 7 8 4 Debugger Arbitration Timing Parameters 40 7 9 Electrical...

Страница 5: ...ter ETAI8 53 8 6 4 XETK ECU Adapter ETAI10 54 8 6 5 Debug Adapter ETAF11 54 8 6 6 Debug Adapter AS_ETAF13 0 55 8 7 Water proof case ETKS_C3 57 9 Ordering Information 58 9 1 XETK S21 0 58 9 2 XETK ECU...

Страница 6: ...ry steps for his are in a step by step guide Target definition 1 Step 1 2 Step 2 3 Step 3 Result DANGER indicates a hazardous situation with a high risk of death or serious injury if not avoided WARNI...

Страница 7: ...Guide 7 1 3 Typographical Conventions Hardware 1 4 Presentation of Supporting Information Bold Menu commands buttons labels of the product Italic Emphasis on content and newly introduced terms NOTE C...

Страница 8: ...ers and Duties for Operators The product may be assembled operated and maintained only if you have the necessary qualification and experience for this product Incorrect operation or operation by users...

Страница 9: ...accessible The module does not have an operating voltage switch Switch on the product by connecting the power supply cable with the power supply or by switching on the power supply Switch off the prod...

Страница 10: ...ive cleaners which could damage the product Transport and Installation CAUTION The ETK can be damaged or destroyed Some components of the ETK board may be damaged or destroyed by elec trostatic discha...

Страница 11: ...s of the product Symbol Description The User Guide must be read prior to the startup of the product Symbol for WEEE see chapter 2 5 on page 12 Marking for CE conformity see chapter 2 6 on page 12 Mark...

Страница 12: ...all ETAS devices but not external cables or batteries For more information on the ETAS GmbH Recycling software contact the ETAS sales and service locations 2 6 CE Conformity With the CE mark attached...

Страница 13: ...tion Products Regulation applicable in China with the China RoHS marking affixed to the product or its packaging 2 9 Declarable Substances European Union Some products from ETAS GmbH e g modules board...

Страница 14: ...XETK S21 0 supports the standard full duplex 100Base T Ethernet inter face and can be connected directly or via ES51x ES59x ES600 modules to the PC No additional ETAS modules are required for the acc...

Страница 15: ...the ECU via the Calibration Wake up pin Pull CalWakeUp until Startup Handshake duration of the Wake up mechanism is configurable ECU flashing via XETK Braindead flashing under ProF control Permanent s...

Страница 16: ...ntent of the data emulation memory can simultaneously be modified by the calibra tion and development system through the XETK Ethernet interface This pro cess enables adjustments of parameters charact...

Страница 17: ...supply for the XETK S21 0 is provided by a switch mode power sup ply to minimize power dissipation 4 2 ECU Interface The XETK S21 0 is connected via connectors CON6 and CON7 to the ECU with two adapte...

Страница 18: ...urement and Calibration standard XCP on Ethernet TCP IP UDP IP The open XCP on Ethernet interface allows for connecting to the XETK S21 0 with third party application software Fig 4 3 Location of the...

Страница 19: ...serial ETK connection it is not available for debugging tools anymore Arbitration mechanisms are required to simultaneously work e g with measurement and calibration tools as well as with debugging t...

Страница 20: ...ndard 16750 From the input battery voltage the XETK S21 0 creates all necessary voltages through switching power supplies on the XETK S21 0 The power supply of the ECU is not affected by the XETK S21...

Страница 21: ...the ECU RAM standby voltage A The XETK S21 0 monitors the VDDSBRAM supply on board the XETK The microcontroller s standby power supply pin must be connected to the XETK pin VDDSBRAM B The XETK S21 0 m...

Страница 22: ...li bration and development system has downloaded data since the last power failure Switching between the Refer ence Page and Working Page is possible On Power supply has dropped under selected thresho...

Страница 23: ...ash to the emula tion space To enable calibration the Working Page must be activated The process of switching from the Reference Page to the Working Page and vice versa is known as page switching The...

Страница 24: ...down resistor is present on the line TRST the ECU must use a value no smaller than 10K ohm as shown in Fig 4 7 on page 24 XETK ETAI10 ETAI5 or ETAI6 or ETAI8 TRST TMS PORST 10k Ubatt GND CAL WAKEUP 1...

Страница 25: ...e microcontrol ler s reference manual 4 11 2 XETK Trigger Generation To generate triggers the ECU software sets bits by writing the associated trig ger index in the DTS_SEMAPHORE register Each bit of...

Страница 26: ...power up or upon INCA request The signals PORST and ESR0 of the microcontroller are used by the XETK S21 0 to detect when the ECU is in reset The XETK S21 0 senses the switched ECU power supply This...

Страница 27: ...con nector details should have been populated onto the ECU PCB for adapters ETAI10 and ETAI5 ETAI6 ETAI8 Fig 5 1 XETK S21 0 Connection to the ECU CAUTION Some components of the interface board may be...

Страница 28: ...2 XETK S21 0 Connection to the ECU ECU Samtec receptacle TFM 105 02 S D P ETAI10 Open Wires JST receptacle B5B PH SM4 TB JST receptacle B7B PH SM4 TB ETAI5 ETAI6 or ETAI8 or Debugger ETAF11 13 Flatca...

Страница 29: ...access to the ECU NOTE The XETK Ethernet interface is compatible with the Ethernet interfaces of the ES51x ES59x ES600 ES910 module P C E S 910 P C CB E 200 3 C B AE 200 2 1 m20 C B AE 330 2 0 m5 Lem...

Страница 30: ...1 0 does not require a galvanically isolated power supply For spe cial applications ETAS offers the isolated power supply ETP2 Fig 5 6 Isolated Power Supply inside ECU ECU 12V ECU GND Permanent Supply...

Страница 31: ...f necessary a plausibility check is performed B Connection of the XETK to the ECU The ECU hardware developer defines the connection of the XETK to the ECU The corresponding signals usually have to be...

Страница 32: ...CT Tool help 1 Start the XCT Tool The main window of the XCT tool opens 2 Select in the menu bar Contents The XCT Tool help window opens 3 Choose Reference to User Interface X ETK Hardware Configurati...

Страница 33: ...with RJ 45 connection is required Ethernet interfaces that are implemented with an additional network card in the PC must feature a 32 bit data bus Requirement to ensure successful initialization of t...

Страница 34: ...ics microcontroller device You need following software versions to support the XETK S21 0 Use case Measurement Calibration ECU Flash Programming Microcontroller INCA INCA MCE HSP ETK Tools MPC5744K ED...

Страница 35: ...1 V4 5 V6 3 V10 7 HBB DISTAB13 MPC5746M ED SPC EMU57EM80 V4 6 V6 4 V10 11 SBB V2 1 V4 5 V6 3 V10 7 HBB DISTAB13 MPC5777M ED SPC EMU57HM90xy V4 6 V6 4 V10 11 SBB V2 1 V4 5 V6 3 V10 7 HBB DISTAB13 MPC57...

Страница 36: ...stics Location Typically located within the emulation memory when using DISTAB13 hooks Measurement data memory can be located in internal RAM if the entire ED RAM is needed for calibra tion Item Chara...

Страница 37: ...ress Dynamic standard for INCA or static e g for Rapid Prototyping by using the XETK Configuration Tool default IP address 192 168 40 16 Cable length max 30 m 100 ft Ethernet Interface DC decoupling N...

Страница 38: ...0 C 240 300 mA Power dissipation PBatt UBatt 12 V I 0 mA at pin ECU_SBRAM T 20 C 1 62 W Power dissipation PBatt UBatt 12 V I 600 mA at pin ECU_SBRAM T 20 C 2 88 W 1 The XETK S21 0 implements reverse v...

Страница 39: ...K S21 0 can process 7 8 1 JTAG Timing Diagram Parameter Symbol Condition Min Typ Max Unit Reset delay 1 1 tReset1 UBatt 12 V VDDP 0 V 3 3 V 5 0 V without transferring FPGA 29 40 ms Reset delay 2 2 tRe...

Страница 40: ...50 MHz Nexus JTAG Clock Frequency TMS TDI Set Up Time ETK Target tsetup 7 min Minimum 5 ns required for microcontroller TMS TDI Hold Time ETK Target thold 7 min Minimum 5 ns required for microcontrol...

Страница 41: ...V selected VDDP VDDP 2 98 3 08 3 18 V VDDP 2 83 2 93 3 03 V IVDDP VDDP 5 0 V 300 A ECU Standby RAM Supervision Voltage 1 25 V selected VDDSBRAM VDDS BRAM_SENSE VDDSBRAM 1 00 1 10 1 20 V VDDSBRAM 1 02...

Страница 42: ...by XETK typ pF 1 TDI TRST O 2 2 3 3 44 12 TMS TCK O 2 2 3 3 44 12 TDO I 0 8 2 5 5 44 12 PORST XIOD2 0 8 2 5 5 3 10 ESR0 I 0 8 2 5 5 3 10 WDGDIS XO 2 2 3 3 22 6 EVTI O3 EVTO I3 Pin Type I Input X Trist...

Страница 43: ...Load by XETK typ pF 1 TDI TRST I 0 8 2 5 5 3 10 TMS TCK I 0 8 2 5 5 3 10 TDO O 2 3 3 3 15 PORST I O2 0 8 2 5 5 3 10 ESR0 O 2 0 2 5 10 WDGDIS I 0 8 2 5 5 3 10 EVTI I3 EVTO O3 Pin Type I Input X Trista...

Страница 44: ...t signal open drain for Reset assertion and supervision B5 VDDP Sense In Sense for Switched power supply of ECU ignition B6 ESR0 In ECU Reset signal for supervision Pin Signal Direction Comment 1 UBAT...

Страница 45: ...GDIS In Watchdog disable signal 6 GND Signal Ground 7 TDI In Debugger event signal currently unused 8 PORST Bidir ECU Reset signal open drain for Reset assertion and supervision 9 TRST In JTAG Signal...

Страница 46: ...on Millimeters Tolerance Millimeters Dimension Inches Tolerance Inches A 60 00 0 20 2 362 0 008 B 56 50 0 20 2 224 0 008 C 3 50 0 10 0 138 0 004 D 3 25 0 10 0 128 0 004 E 37 25 0 20 1 466 0 008 F 40 2...

Страница 47: ...unting M12 0 38 m length shield connected to socket Usable for ECUs with shielded hous ing 8 1 2 CBAM240 Adapter Cable Fig 8 2 CBAM240 Adapter Cable XETK ECU Adapter Cable 100 MBit s shield connected...

Страница 48: ...Mbit s pre assembled into PG9 screwing shield on ECU housing Lemo 1B PHE JST PHR 10fc 5fc 0 5 m length Fits for ETKS_C3 case NOTE For mounting the cable cut a PG9 thread into the ECU housing For thin...

Страница 49: ...emo 1B PHE JST PHR 10fc 5fc Lemo 0B PHG JST PAP 2fc 2fc 0 5 m and 0 7 m length NOTE For using the cable with an ETK with solder pad cut the plug and solder the wire direct to the solder pad NOTE It is...

Страница 50: ...e Cable adapter to connect CBE230 cable to the PC over an RJ45 connector The CBAE200 2 1m20 supports Gigabit Ethernet Product Length Order Number CBAM270 1 0m5 0 5 m F 00K 107 866 CBAM270 1 0m7 0 7 m...

Страница 51: ...bit Ethernet cable with power supply 8 4 2 CBAE330 Adapter Cable Fig 8 9 CBAE330 Adapter Cable Gigabit to 100 MBit s Ethernet Adapter for connection of CBE230 to ES600 Cable adapter to connect CBE230...

Страница 52: ...TK S21 0B User Guide 52 8 5 Power Supply Cables 8 5 1 Cable K70 Fig 8 10 Power Supply Cable K70 8 5 2 Cable KA50 Fig 8 11 Power Supply Cable KA50 Dim Millimeters Inches A 2000 78 74 Dim Millimeters In...

Страница 53: ...r ETAI6 8 6 3 XETK ECU Adapter ETAI8 Fig 8 14 XETK ECU Adapter ETAI8 Dim Millimeters Inches A 250 9 84 NOTE See Fig 5 2 on page 28 for details on mating connector to the ETAI5 Dim Millimeters Inches A...

Страница 54: ...connec tion The ETAF11 bottom side is isolated no parts and vias There are two specific applications adapt the ECU ETK connector to the Debugger adapt the ETK Debugger connector to the Debugger ETAF11...

Страница 55: ...PCB Fig 8 18 ETAF11 Mechanical Dimensions and Component Placement 8 6 6 Debug Adapter AS_ETAF13 0 The AS_ETAF13 0 adapts the Lauterbach Auto 26 cable 26 pin Samtec to the XETK S21 0 debug connector 16...

Страница 56: ...User Guide 56 AS_ETAF13 0 Debug Adapter Fig 8 19 AS_ETAF13 0 Debug Adapter AS_ETAF13 0 Top Plugs into Debugger AS_ETAF13 0 Bottom Plugs into Ribbon cable AS_ETAF13 0 Debugger Adapter Board 3D view AS...

Страница 57: ...User Guide 57 8 7 Water proof case ETKS_C3 For mounting the XETK S21 0 on top of ECUs an external case is available It is small robust and water proof IP65 Fig 8 20 ETKS_C3 Top View Fig 8 21 ETKS_C3...

Страница 58: ...act_cn Order Name Short Name Order Number ETAI5 ETK ECU Adapter with short ED supply and GND lines JST PHR open wires 7fc 2c 5c 0m25 ETAI5 F 00K 106 773 ETAI6 ETK ECU Adapter JST PHR JST PHR 7fc 5fc 0...

Страница 59: ...r Number XETK ECU Adapter Cable 100 Mbit s Shield on ECU Housing Lemo 1B HME JST PHE 10fc 5fc 0m38 CBAM230 1 0m38 F 00K 105 791 XETK ECU Adapter cable 100 Mbit s Lemo 1B HME JST PHE 10fc 5fc 0m6 CBAM2...

Страница 60: ...ction Cable 1 GBit s Lemo 1B FGE Lemo 1B FGE 10mc 10mc 3 m CBE230 1 3 F 00K 105 757 Ethernet Connection Cable 1 GBit s Lemo 1B FGE Lemo 1B FGE 10mc 10mc 8 m CBE230 1 8 F 00K 105 758 Order Name Short N...

Страница 61: ...ails of your local sales office as well as your local technical support team and product hotlines take a look at the ETAS website Borsigstra e 24 Phone 49 711 3423 0 70469 Stuttgart Fax 49 711 3423 21...

Страница 62: ...Power Supply inside ECU available 30 Fig 5 5 Permanent Power Supply inside ECU not available 30 Fig 5 6 Isolated Power Supply inside ECU 30 Fig 7 1 XETK S21 0 Dimensions Top View 46 Fig 7 2 XETK S21 0...

Страница 63: ...ETAS Figures XETK S21 0B User Guide 63 Fig 8 19 AS_ETAF13 0 Debug Adapter 56 Fig 8 20 ETKS_C3 Top View 57 Fig 8 21 ETKS_C3 Bottom View 57 Fig 8 22 ETKS_C3 Side View 57...

Страница 64: ...hernet Interface 18 ETK Configuration 31 ETKS_C3 57 F Features 15 H Hardware Description 16 I Identifications on the product 11 Interface Cables 47 ECU 17 19 Introduction 14 Isolated Power Supply 30 L...

Страница 65: ...XETK S21 0B User Guide 65 ETAS Index X XETK Ethernet Interface 18...

Отзывы: