Installation
5
Installation
In this chapter, the hardware installation of the ETK-V1.1 is described.
5.1
Connection to the ECU
For mounting the ETK-V1.1 on the ECU accessories are required:
• a VertiCal base board
• an Advanced Interconnect socket, mounted on the ECU printed circuit
board (only when using a VertiCal base board with pin array).
It need to be ordered seperately (refer chapter "Ordering Information"
on page 56).
5.1.1
VertiCal Base Board soldered on ECU PCB
Fig. 5-1
ETK-V1.1 soldered Connection to the ECU
The VertiCal base board fitted with solder ball footprints is used for direct and
permanent connection to the development ECU (see Fig. 5-1).
CAUTION!
Some components of the interface board may be damaged or
destroyed by electrostatic discharges. Please keep the board in its
storage package until it is installed.
The board should only be taken from its package, configured, and
installed at a work place that is protected against static discharge.
CAUTION!
Risk of short circuiting the internal signals of the ETK!
When you mount the ETK to the ECU, you must ensure that the
screws and washers used will not penetrate the ETK printed circuit
board.
ECU
VertiCal Base Board (* )
(* ) Not delivered with ETKV1.0
VertiCal Top Board
(ETKV1.0)
VertiCal Adapter