ES5340.2 Electric Drive Simulation Board - User’s Guide
56
FPGA Models
ETAS
Inputs
You can connect the inputs of the PMSM model to other models (in the Connec-
tion Manager of LABCAR-IP) or stimulate them in the Signal Center in
LABCAR-EE.
Tab. 4-5
Inputs of the PMSM model
Outputs
You can connect the outputs of the PMSM model with analog or digital outputs
(in LABCAR-RTC) and to other models (in the Connection Manager of
LABCAR-IP).
Tab. 4-6
Outputs of the PMSM Model
Input [unit]
Description
Default value
Rd [
Ω
]
Coil resistance in d direction
0.0125
Rq [
Ω
]
Coil resistance in q direction
0.0125
Ld [H]
Coil inductance in d direction
0.000211
Lq [H]
Coil inductance in q direction
0.000211
Psi [Vs]
Magnetic flux
0.0382
Theta_M [°C]
Engine temperature
20.0
Output
[unit]
Description
Signal available as
multiplexer input
I_d [A]
Current in d direction
Analog MUX
I_q [A]
Current in q direction
Analog MUX
I_phase_X
(X=U,V,W) [A]
Current Phase X
Analog MUX
U_back_EMF_X
(X=U,V,W) [V]
Voltage X back EMF
Analog MUX
ZeroPos []
Signal is active if phase voltage
U_Phase_U > U_Phase_V
Digital_MUX
T_el [Nm]
Torque of electric motor
-
P_Loss_M [W]
Ohmic losses of the motor
-
Содержание ES5340.2
Страница 1: ...ES5340 2 Electric Drive Simulation Board User s Guide...
Страница 6: ...ES5340 2 Electric Drive Simulation Board User s Guide 6 Contents ETAS...
Страница 22: ...ES5340 2 Electric Drive Simulation Board User s Guide 22 Introduction ETAS...
Страница 102: ...ES5340 2 Electric Drive Simulation Board User s Guide 102 Connector Assignment and Display Elements ETAS...
Страница 110: ...ES5340 2 Electric Drive Simulation Board User s Guide 110 Order Information and Scope of Delivery ETAS...
Страница 116: ...ES5340 2 Electric Drive Simulation Board User s Guide 116 ETAS Contact Addresses ETAS...
Страница 118: ...ES5340 2 Electric Drive Simulation Board User s Guide 118 Figures ETAS...