ETAS
Getting Started
ES430.1 - User’s Guide
40
6
Getting Started
This chapter contains information on the following topics:
• “General Installation Recommendations” on page 40
• “Assembly” on page 41
• “Drilling Template” on page 55
• “Installing the Lambda Sensor” on page 56
• “Applications” on page 59
• “Wiring Examples” on page 61
• “Wiring” on page 66
• “Calibrate to Air” on page 68
6.1
General Installation Recommendations
6.1.1
Assembly Environment and Components for Attaching the
Module
Adhere to the technical data of the modules for operation, such as
• the vibration resistance of the modules (only assemble modules on
sprung masses, for example, and not on wheel suspensions or directly
on the engine) and
• the temperature resistance of the modules (for example do not assem
-
ble modules on the engine, turbocharger, exhaust manifold or within
their vicinity).
6.1.2
Potential Equalization in the Vehicle and Mounting the Mod
-
ules
CAUTION
The module can be damaged or destroyed.
The modules of the ES400 line are only admissible for assembly and opera
-
tion on components or in locations which guarantee adherence to the techni
-
cal data of the modules during operation (see chapter 8 on page 79).
CAUTION
Potential equalization in the vehicle over the shield of the Ethernet connect
-
ing cables of modules may occur!
Mount the modules only to components with the same electrical potential or
insulate the modules from the components.