ETAS
Technical Data
ES420.1 - User’s Guide
71
Operating the ES420.1 with limited function scope is possible using the follow
-
ing INCA versions:
• INCA V5.3 with ES4xx Configuration Tool V1.0.2 from ES4xx_DRV_SW
or
• INCA V5.4 with ES4xx Configuration Tool V1.0.2 from ES4xx_DRV_SW
or
• INCA V5.4.1 and higher
or
• ES4xx Configuration Tool V1.0.4 from ES4xx_DRV_SW (stand-alone
operation).
7.8
Electrical Data
This chapter contains information on the following topics:
• “Power Supply” on page 71
• “Host Interface” on page 72
• “Sensor Inputs” on page 72
7.8.1
Power Supply
1)
: The module may be used only with central load dump protection.
TIP
Operating the ES420.1 with older versions of software is not possible.
TIP
ETAS guarantees measurement accuracy of the ES420.1 for one year. Please
use our calibration service (see section 4.10 on page 31)!
TIP
Unless otherwise specified, all data applies at 25 °C.
Operating voltage
Temperature range -40 °C to +85 °C:
5 V to 50 V DC
Temperature range -40 °C to +120 °C:
6 V to 50 V DC
Power consumption (operation)
Typ. 2 W at 12 V DC
Power consumption (standby)
Typ. 25 mW at 12 V DC
Polarity inversion protection, load
dump protection
1)
With CBEP410, CBEP4105, CBEP415,
CBEP4155, CBEP420, CBEP4205,
CBEP425, CBEP4255, CBEP430,
CBEP4305 cable