[Pellet store with switch unit] function block
ETAtouch controller
5.10
[Pellet store with switch unit]
function block
Overview of pellet store with switching unit
Up to 4 suction heads can be controlled by one
switching unit.
1
Operating condition and information.
A description of the operating conditions can be
found in the integrated Help menu by pressing the
button.
2
Current pellet stock.
This is calculated by the control system and can
therefore differ by +/- 15% from the actual pellet
supply
3
Manually switch to next enabled suction probe
4
Enter new stock levels after filling
5
Suction probe enabled: pellets can be conveyed
from this suction probe.
6
Suction probe restricted: this suction probe is not
activated by the switching unit
[Stock level] button
After filling the pellet store, a new supply of
pellets is fed in with this button.
Example: 1200 kg of pellets are available, and
3000 kg is refilled. The new stock will be registered as
4200 kg.
Manually changing suction probes
This button manually switches to the next
enabled suction probe, in order to move the
pellets.
Disabling and enabling a suction probe
This symbol represents an enabled suction
probe. This can be controlled by the switching
unit for conveying the pellets. If an enabled
suction probe is selected, then this is locked (
symbol). It will then no longer be activated by the
switching unit. By re-selecting the locked suction
probe, it is enabled again (
symbol).
Function of the switching unit
The conveying and clear modes are represented by a
green line between an enabled suction head and the
switch unit. If a suction head is no longer able to
convey pellets, the control system automatically
switches to clear mode. Here, the conveying hose now
introduces back air, in order to dislodge any blockages
in the conveying hose or suction head.
If an enabled suction probe is selected (
symbol),
this is then locked (
symbol). It will then no longer be
activated by the switching unit. Re-selection of the
locked suction probe frees it again (
symbol).
The switch unit regularly switches between the
individual, enabled suction heads, to ensure that the
pellet store is emptied uniformly. You can adjust the
maximum number of fill-up operations by a suction
head, see
With the
button, you can also manually change
to another enabled suction probe.
Entering a minimum level for the pellet stock
You can define a minimum level for the pellet stock so
that a warning is issued when the stock goes below
that level.
The minimum level is set with the [Warning limit for
pellet stock] parameter in the text menu of the pellet
stock.
5.10.1
Text menu - Adjustable parameters
5.10.1.1
Switching at
Explanation of [Switching at]
This parameter sets the maximum number of suction
operations of an enabled suction head. When a
suction head has reached this number, the switch unit
automatically changes to the next enabled suction
head.
The parameter can be found under:
Conveying system
Switching at
Содержание PelletsCompact33-50 kW
Страница 1: ...2017 04 19 EN 0000000285 V 003 3 38 0 2703 93120 002 PelletsCompact 33 50 kW Operation...
Страница 27: ...ETAtouch controller Getting to know the control system 27...
Страница 31: ...ETAtouch controller Boiler function block PelletsCompact 33 50 kW 31...
Страница 41: ...ETAtouch controller Buffer function block 41...
Страница 45: ...ETAtouch controller Hot water tank function block 45...
Страница 49: ...ETAtouch controller Fresh water module function block 49...
Страница 63: ...ETAtouch controller Solar function block 63...
Страница 67: ...ETAtouch controller Pellet store function block 67...
Страница 74: ...www eta co at...
Страница 75: ......
Страница 76: ...www eta co at www eta co at downloads DOWNLOAD...