ETAtouch controller
[Boiler] function block - PelletsCompact 20-32 kW
29
temperature for measurement purposes. By pressing
the [Start now]
button, the boiler will immediately
begin preparations for a subsequent measurement.
Fig. 5-35: Settings window for emission measurement
In addition, the locking time of the boiler can be
adjusted in the settings window (
[Lock duration]
button). This relates to the set time of the measure-
ment. During this period no heating operation will be
started, so that the heating system has time to cool
down.
Example: If a time of 17:00 is set for the emission
measurement and at [Lock duration] 8 h, heating will
end at 09:00 .
The [Deactivate measurement]
button ends the
emission measurement and switches the boiler back to
normal mode.
Settings menu
In the settings menu (
[Settings] button in the
overview), the following functions and parameters can
also be set:
[Fill-up time] button
This sets the daily time for complete refilling of
the boiler pellet bin if pellets have been used.
This prevents refilling during the night. This
time applies for every day of the week.
[Hopper Fill] button
This fills the reservoir on the boiler immediately,
independent of the suction time settings.
5.2.2
Text menu - Adjustable parameters
Adjustable parameters
Detailed descriptions of the parameters are provided
below.
5.2.2.1
Setting the idle time for boiler de-
ashing
Explanation of [Duration idle time]
The [Duration idle time] parameter is used to select the
duration of the idle time for the boiler's entire de-ashing
system.
The start time for the idle time is set with the [Start idle
time] parameter.
The idle time should be kept as short as possible.
If noise is not expected to be a nuisance, you
should reduce the value to 0 hours.
The parameters can be found under:
5.2.2.2
Boiler de-ashing interval
Explanation of [De-ash after min.] and [De-ash
after max.]
The boiler's de-ashing interval is set with the [De-ash
after min.] and [De-ash after max.] parameters. The
boiler de-ashes within the range specified by these two
parameters.
The de-ashing interval may only be modified after
consultation with a specialist or ETA customer
service.
The parameters can be found under:
Boiler
Ash removal
Start idle time
Duration idle time
De-ash after min.
De-ash after max.
Empty ash box after
Boiler
Ash removal
Start idle time
Duration idle time
Boiler
Ash removal
De-ash after min.
De-ash after max.
Содержание PelletsCompact 20-32 kW
Страница 1: ...2017 04 19 EN 0000000282 V 003 3 38 1 1910 93108 002 PelletsCompact 20 32 kW Operation...
Страница 27: ...ETAtouch controller Getting to know the control system 27...
Страница 31: ...ETAtouch controller Boiler function block PelletsCompact 20 32 kW 31...
Страница 41: ...ETAtouch controller Buffer function block 41...
Страница 45: ...ETAtouch controller Hot water tank function block 45...
Страница 49: ...ETAtouch controller Fresh water module function block 49...
Страница 63: ...ETAtouch controller Solar function block 63...
Страница 67: ...ETAtouch controller Pellet store function block 67...
Страница 74: ...www eta co at...
Страница 75: ......
Страница 76: ...www eta co at www eta co at downloads DOWNLOAD...