Suction micro-filter
Take out grid
A8
with filter
A17
by pulling it upwards (Fig. 16). Remove the filter from the
grid (Fig. 17) and clean it in running lukewarm water, e.g. using a cloth or a soft brush and
let it dry completely (Fig. 19). After drying, put the grid with a new micro-filter in the opposite
direction behind the guide ribs and slide it to the suction area of the vacuum cleaner to the
maximum position.
Exhaust micro-filter
Take out exhaust grid
A12
from the vacuum cleaner by pulling it upwards (Fig. 18). Take
out foam filters
A13
from the grid and remove Tap the dust out of the filter over a dustbin or
to clean the filter through a blowing (we recommend the filter cleaning outside of living area
for hygiene reasons). If the protection micro filter is very dirty, you can also rinse the pleated
side of the HEPA filter under lukewarm slow-running tap. Hold the filter in such a way that
the pleated side points upwards and the water flows parallel to the pleats. Hold the filter at
an angle so that the water washes away the dirt inside the pleats. Turn the filter 180° and
let the water flow along the pleats in the opposite direction. Continue this process until the
filter is clean. After drying, insert the cartridge back to the vacuum cleaner in the opposite
way. Insert the projections on the back cover into two holes in the vacuum cleaner cover and
snap the cover.
Storing accessories
The accessories, the floor nozzle, the suction tubes and the hose can be dismantled again
or left assembled and hung on the back side or on the bottom of the vacuum cleaner into the
storage position (Fig. 20). For better stability, slide individual parts of the tube to each other
so that the tube is as short as possible. When storing, always set the floor nozzle to the
carpet position (i.e. with the brush retracted); thus you will prevent bending of the bristles.
V. MAINTENANCE
Store the vacuum cleaner at a dry place, far enough from heat sources (e.g.
fireplace,
stove, heating element
) and protect it from weather conditions (e.g.
rain, sunshine
).
Treat surface of the appliance with a soft and damp cloth, do not use coarse and aggressive
detergents! Store the appliance properly cleaned at a dry, dust-free place out of reach
of children and incapacitated people.
ATTENTION
– The „UniBag” dust filter is not intended for repeated use.
– DO NOT THROW THE ADAPTER AWAY!
– Do not use any aggressive washing or cleaning agents or hot water to clean the HEPA
filter and the micro-filter.
– Cleaning the filter will not restore its original colour, but it will restore its filtration
properties.
– The HEPA filter and the micro-filters are not intended for cleaning in a dishwasher.
– Proper insertion of the dust filter to the holder will secure the mechanical safety lock.
Now you can close the lid of the vacuum cleaner
– Neglecting regular replacement of micro-filters can result in the vacuum cleaner failure!
– Make sure that the contact surfaces and sealing elements are functional.
– We recommend replacing the HEPA filter twice a year. Replace the other micro-filters
if they cannot be cleaned properly or if they are damaged. You can buy a replacement
dust filter, a HEPA filter and a micro-filter in the elektro shop chain.
!