SOLENOID DRIVEN METERING PUMPS 

WITH DIAPHRAGM 

EN

AMS DIGITAL - AMSA DIGITAL

OPERA

TING MANU

AL

AMS DIGITAL 

AMSA DIGITAL

Содержание AMS DIGITAL

Страница 1: ...SOLENOID DRIVEN METERING PUMPS WITH DIAPHRAGM EN AMS DIGITAL AMSA DIGITAL OPERATING MANUAL AMS DIGITAL AMSA DIGITAL...

Страница 2: ...ad electromagn tica Norme armonizzate europee nell ambito della direttiva European harmonized standards underdirective Las normas europeas armonizadas conforme a la directiva 2006 95 CE 2004 108 CE 20...

Страница 3: ...lling always observe national regulations Manufacturer is not liable for any unauthorized use or misuse of this product that may cause injury damage to persons or materials Pump must be accessible at...

Страница 4: ...delines EWC code 16 02 14 Always recycle according to these guidelines 1 If the unit or parts are accepted by an authorized recycling company then follow local recycling laws and regulations 2 If the...

Страница 5: ...of chemicals Before return the dosing pump to the manufacturer Repair service drain the chemical from pump head and rinse it Refer to Shutdown procedure Fill the PRODUCT SERVICE REPAIR FORM and send...

Страница 6: ...justable from 0 to 100 using the stroke length adjustment knob However dosin accuracy is guarantee within an adjustment range from 30 to 100 1 3 Models AMS PH Proportional pump driven by internal buil...

Страница 7: ...m 2 Delivery pipe PVDF m 2 Suction pipe transparent PVC m 2 Venting pipe transparent PVC m 2 5 Signal cable for Stand by and Alarm n 1 This installation manual If hose is 6x8 there is only a 4meters l...

Страница 8: ...racy is guarantee within an adjustment range from 30 to 100 Note if knob isn t on 100 position then the pump will dose at pressure greater than the one declared on label Manual stroke length adjustmen...

Страница 9: ...n vertical position All hoses connections must be performed using only hands force No tongs required Delivery hose must be firmly fixed to avoid suddenly movements that could damage near objects Sucti...

Страница 10: ...or example a table at a maximum height from tank s bottom of 1 5 meters 1 Dosing Pump 2 Suction Hose 3 Delivery Hose 4 Injection Valve 5 Air discharge 6 Level Probe 7 Foot Filter 8 Power Cable 9 Stand...

Страница 11: ...Completely unscrew tightening nut from pump s head and remove assembling components tightening nut holding ring and pipe holder Assembly as shown in fig A Insert hose into pipe holder until it reaches...

Страница 12: ...g nut from pump s head and remove assembling components tightening nut holding ring and pipe holder Assembly as shown in fig A Insert hose into pipe holder until it reaches the bottom Lock hose on pum...

Страница 13: ...ill flow into tank Injection Valve Injection valve must be installed on plant from water s input Injection valve will open at pressure greater than 0 3bar 4 5 6 7 To manual venting hose Venting knob f...

Страница 14: ...uce gas i e hydrogen peroxide ammonium sodium hypoclorite at particular conditions Refer to fig 4 5 for delivery and venting hose Hoses assembling procedures are the same described before Fig 3 Self v...

Страница 15: ...witch 0 03A sensitivity if there isn t a good ground to avoid damages to the pump do not install it in parallel with heavy inductance load for example engines A relay switch must be used See below pic...

Страница 16: ...WARNING IF EQUIPMENT IS NOT SUPPLIED WITH A PLUG a a switch or circuit breaker shall be included in the building installation b it shall be in close proximity to the equipment and within easy reach of...

Страница 17: ...obe is connected to the right BNC plug on pump s bottom panel The level probe is made of a N O reed contact 10VA 1A max 230Vac max closed by a floating magnet housed in a PP plastic box When the produ...

Страница 18: ...sion pump will stop and display will show HI VI meaning HIGH VOLTAGE INPUT SYNC Every time pump is powered by the main electrical supply display shows SYNC for 1 second The message indicates that the...

Страница 19: ...ith serial programming responds only when required The reply message contains all data shown on the display see paragraph Display Information including the number of the pulses released by the pump wh...

Страница 20: ...all keys will be described as shown on this legend UP key RIGHT key DOWN key E key Entering in program mode Turn on the pump Keep pressed E key for at least 4 seconds to enter in program mode Pump s d...

Страница 21: ...ution temperature and verify if it is the same printed on solution s label 2 Insert probe s connector blue colour into pump s input connector 3 Remove protective cap from probe and wash it into water...

Страница 22: ...3 Alarm and press E key The pump shows AL OFF DOSING fig 10 To activate the alarm use UP or DOWN keys to set the time from 1 to 100 minutes or AL OFF To setup the alarm mode use the RIGHT key Cursor m...

Страница 23: ...bubbles inside hydraulic circuit Check valves hoses fittings Product to dose is generating gas Turn venting knob and let air flow away Use a self venting pump head Pump is not dosing and sole noid isn...

Страница 24: ...pump s back Pull pump s back cover until it s completed separated from pump s front Be careful of the knob s spring Locate the blown fuse and replace with another one having same rating Reassemble th...

Страница 25: ...28 Mod AMS Ext 485 Transformer Power supply Solenoid FUSE Level Signal Signals for AMS Ext 485 model only 16 Main Board...

Страница 26: ...gulations Use original spare parts Shutdown the dosing pump before any maintenance operation Shutdown procedure A maintenance schedule includes these types of inspections Routine maintenance and inspe...

Страница 27: ...urity device if necessary Shutdown the dosing pump before any maintenance operation or before long downtimes Disconnect power and ensure it cannot be restarted Depressurize the system The liquid may l...

Страница 28: ...cc h max l h Min GPH Max GPH 230 VAC 115 VAC min max bar PSI 253 2 0 13 3 2 0 00003 0 85 0 13 0 44 120 25 362 2 5 2 5 4 x 6 4x 8 LA 1506 0 25 6 0 00007 1 59 0 25 0 83 120 15 217 2 5 2 5 4 x 6 4 x 8 MA...

Страница 29: ...10 l h 10 bar 15 Pump head mod M l h bar l h bar l h bar 0720 l h 20 bar 7 Pump head mod N 0340 l h 40 bar 3 Pump head mod S 0260 l h 60 bar 2 Pump head mod T l h bar Flow rate indicated is for H2 O a...

Страница 30: ...e Dosing accuracy 2 at constant pressure 0 5 bar 253 2 l h 25 bar 3 2 Pump head mod LA l h bar 1506 l h 6 bar 15 Pump head mod MA l h bar 0713 l h 13 bar 7 Pump head mod NA l h bar 1010 l h 10 bar 10...

Страница 31: ...138 00 139 50 127 00 87 00 237 80 141 50 152 60 154 80 211 40 124 80 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A B C D E F Progettato da Controllato da Modificato da il Data Edizione Dimensionale CMS_Cp_S T Ma...

Страница 32: ...1 3 3 3 Amines R NH2 1 2 1 3 1 1 1 3 3 1 1 Sodium Bisulphite NaHSO3 1 1 1 1 2 1 1 1 1 1 1 1 Sodium Carbonate Soda Na2CO3 2 3 1 1 1 1 1 1 2 1 1 1 Ferric Chloride FeCl3 1 1 1 1 3 1 1 1 1 1 1 1 Calcium H...

Страница 33: ...e Every pump s model is made to work in the best way using selected hoses according to pump s capacity model Information reported here are intended for standard use only For extended information ask t...

Страница 34: ...37 H...

Страница 35: ...38 h Appendix Exploded view 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D E E F F Edizione Foglio Esploso_CMSMF_CP_T 00 1 1 1 2 3 4 5 6 23 22 21 20 19 7 18 17 8 16 10 9 15 14 13 12 11...

Страница 36: ...tion 15 9 Priming level alarm threshold value 17 10 Basic settings 18 11 AMS EXT RS485 model 19 12 AMS RH model 20 13 AMS PH model 23 14 Troubleshooting 26 15 Fuse and main board replacement 27 16 Mai...

Страница 37: ...ETA Ekipman Teknoloji Ar Sis San Tic Ltd ti www etaekipman com info etaekipman com Tel 0 216 540 99 64 Fax 0 216 540 99 68...