ETA Systems ETA-S20 Скачать руководство пользователя страница 6

 

– 6 – 

ETAsys.com

Specifications are subject to change without notice.

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

ETA-S20 

AC Power Distribution Unit & Surge Suppressor

FRONT PANEL FEATURES 

1. Unswitched AC Outlet

The 120VAC 20A NEMA 5-20R outlet is always live when the ETA-S20 power cord is plugged into an AC Mains power source and 
voltage is present. 

Note:

 The AC Mains power switch does not affect the Unswitched AC Outlet. The Unswitched Outlet is protected 

by the surge protection circuitry.

2. AC Mains Breaker  

The 120VAC 20A 2500W rated breaker will open if the combined draw of all AC outlets exceeds 20A. 

Note:

 The breaker is designed to 

exceed its rating for a short period of time. If the breaker is tripped, you must first remove the load from the ETA-S20 and then push to 
reset.

3. Power Switch 

To turn the ETA-S20 On or Off, press the switch to the ON or OFF position. This switch powers the “switched” outlets. The switch     
will illuminate Red when it is in the ON position.

4. Power AC Present LED 

Will illuminate Red when the AC Mains Power Switch is in the ON position.

5. AC Protect Active LED

Although the Clamping Suppression circuit virtually assures protection from most transient voltage spikes and surges, nature has 
a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of 
damage. In the rare instance that this occurs and the circuit has been damaged, the Green “AC Protect Active” LED indicator will turn 
Off, indicating that the AC Protect Circuitry is no longer protecting equipment connected to the Switched outlets. The unit will still 
operate as an AC distribution unit but the surge suppressor protection will not function until the unit is repaired. 

Note:

 Be advised that 

activation of this fault condition and the associated repair is not covered under warranty. If the AC Protect is disengaged, it is important 
to have all equipment that was connected to that AC Mains Line be inspected for proper operation.

REAR PANEL FEATURES

1. AC Mains Input

  

Connect the 12 gauge 9' (2.74m) power cord to a 20A 120VAC outlet to provide power to the ETA-S20.

2. AC Power Outlets Switched

Seven 120VAC 20A NEMA 5-20R outlets are “Live” when the front panel power switch is activated. 

3. Unswitched AC Outlet

 

The 120VAC 20A NEMA 5-20R outlet is always live when the ETA-S20 power cord is plugged into an AC mains power source and 
voltage is present. 

Note:

 The AC mains power switch does not affect the Unswitched AC Outlet. The Unswitched Outlet is protected 

by the surge protection circuitry.

1

2

3

5

4

1

3

2

Содержание ETA-S20

Страница 1: ...s are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA S20 AC Power Distribution Unit Surge Suppressor ETA S20 AC Power Distrib...

Страница 2: ...as 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA S20 AC Power Distribution Unit Surge Suppressor TABLE OF CONTENTS Important Safety Instructions 3 Introduction 5 Key Features 5 Applications...

Страница 3: ...tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip over 13 Unplug this devi...

Страница 4: ...speaker terminals as electric shock may result Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be su...

Страница 5: ...is very fast and can suppress unwanted energy within a nanosecond response and sustain the suppression up to 2 milliseconds thus ensuring virtually trouble free protection If the suppression circuitr...

Страница 6: ...n from most transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of damage In th...

Страница 7: ...Power Distribution Surge Suppressor Front Panel Outlets 20A NEMA 5 20R 1 Unswitched Activation Switch Rocker Illuminates Red when in the ON position Circuit Breaker 20A Resettable Indicators AC Power...

Страница 8: ...forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is inclu...

Отзывы: