Action 

Response

U ntil 5sec  beep begins. 

To unlock repeat 

Holiday lock-out  

Av ailable in all but Complex  Auto-close mode.

1.

Close gate

2.

Press and hold the PED (pedestrian) 

button on a master remote

3.

Release PED (pedestrian) button on 

master remote

Beeping w ill continue until confirmation or 5sec 

expires. 

4.

Press and release BT (full opening) 

button on the master remote before 5sec 

beep stop.

1 x  multiple rapid beeps w ill confirm holiday lock-

out is activ e. 

After multiple confirmation beeps gate w ill 

immediately start opening w hen unlocked.

Holiday lock-out is av ailable only w hen using a master remote. (No hardw ired dev ices w ill activ ate)

A  master remote is a remote that has BT (full opening) control as well as PED (Pedestrian) opening control.

If no BT (full opening) confirmation trigger is receiv ed by the time the intermittent beeps stop (5sec.), the gate w ill not 

change status.

Auto-close override

Action 

Response

1 x long beep and gate starts closing.

P arty mode  

Av ailable in all but Complex Auto-close mode.

1.

With the gate at any open position

2.

Press and hold any TX (transmitter) 

BT (full opening) button

After 5sec unit will emit Multiple rapid beeps to 

confirm.

3.

Release input after beeps

Gate will not begin closing after auto-close time 

has expired.

4.

To deactiv ate repeat 2 and 3 

abov e

If any PED (Pedestrian) or BT (full opening) input is momentarily activ ated while the unit is in either Holiday lock-out or 

Auto-close ov erride/Party mode the unit will only emit the multiple rapid beeps and not run the gate. 

Содержание Umpetha

Страница 1: ...UMPETHA U 082009 072010 012 USER GUIDE 1 Domestic sliding gate operator by ET SYSTEMS...

Страница 2: ...p antenna for the detection of motor v ehicles installed in the driveway surface Table of contents Page Description 3 Manual ov erride 3 4 Standard mode 4 Simple auto close mode 4 Condominium mode 4 P...

Страница 3: ...gency override to the end user It is also the responsibility of the installer service provider to issue all end user documentation which accompanies this product to the end user It is the responsibili...

Страница 4: ...liday lock out Auto close ov erride Party mode and Master remote programming Mode P I R A C Auto close In this mode the unit will operate as per Simple auto close abov e The added feature here is quic...

Страница 5: ...Collision lock out routine Collision with closed stopper due to faulty or missing closed limit All modes If no limit input is made when expected as calculated by the programmed run time the UMPETHA wi...

Страница 6: ...the built in RX as well Feature not av ailable in Condo loop mode Feature limited to learning in BT operation transmitters only 1 Open gate fully using the RX master remote Gate runs to full open posi...

Страница 7: ...aster remote is a remote that has BT full opening control as well as PED Pedestrian opening control If no BT full opening confirmation trigger is receiv ed by the time the intermittent beeps stop 5sec...

Страница 8: ...x devices overload If problem persists after 8 hours charging replace battery 3 x 1sec Beeps Gate closed Off Momentary Ped Gate opens partially Pedestrian function activated pg 27 2 x 2sec Beeps Gate...

Страница 9: ...out in the applicable documentation accompanying said goods is adhered to All warranty claims must be accompanied by the original invoice All claims made by the end user must be directed to their res...

Отзывы: