5 • TESTINg / MaINTENaNCE
The detector can be fully tested using the test button
(fig. 1d)
. Perform a test at least once
a month. Press the test button (for up to 5 seconds) until a loud, pulsating alarm signal
(approx. 85 dB) can be heard. When necessary (usually about twice a year), wipe the
device with a clean, dry cloth and clean the outside with a vacuum cleaner. The device
automatically performs a test. If there is a fault, the
orange LED (fig. 1b)
will light up
continuously. This indicates that the detector needs to be replaced.
NOTE: To ensure your safety, the PROTECTOR GD 230 V ∼ is designed to be highly sensitive.
For this reason, the sensor may also react to other gases (e.g. propellants in aerosol spray cans
and disinfectant sprays).
6 • aCCESSoRIES
ESYLUX PROTECTOR switching relay
7 • aCTIoN IN THE EVENT of aN alaRM
• Do not smoke. Do not light a flame.
• Do
not
unplug the PROTECTOR GD 230 V ∼ or any other device from the mains.
• Press the test button
(fig. 1d)
to silence the PROTECTOR GD 230 V ∼ for approx.
10 minutes.
• Open doors and windows fully. When ventilating the building, please note the
properties of the particular gas:
-
Natural gas (CNG, methane)
is lighter than air and collects beneath the ceiling.
-
Liquefied/bottled gas (LPG, propane/butane)
is heavier than air and collects at floor level.
• Disconnect the gas supply at the main cock/bottle valve.
• Arrange for an engineer to check your gas appliance.
green LED (fig. 1a)
orange LED (fig. 1b)
red LED (fig. 1c)
Alarm signal/Piezo
Description
lights up
continuously
off
off
off
device is
operational
flashes (over approx.
10 min. period)
off
off
off
warm-up phase
lights up
continuously
off
flashes
intermittent alarm
signal
alarm, see
Section 7 for
action to take
lights up
continuously
leuchtet
permanent
off
off
fault,
change device
lights up
continuously
flashes
flashes
intermittent alarm
signal
Testalarm
lights up
continuously
off
flashes
short beep every
45 sec.
alarm has been
silenced
4 • fEaTuRES