19
• If you want to change a setting option of the currently selected
panel, press the
PROG/OK
button once. The setting option 1 of
the screen will now flash as a sign that it can be changed.
• For changing the respective setting
use the (+) and (-) buttons. Press the button until the display shows
the desired value. The decoder immediately applies the changes so
you can see immediately what is happening.
• Confirm your entry with
PROG/OK
. After that, the next setting
option will flash as a sign that it can now be changed.
If you do not want to change a setting option, but only want to
proceed to the next one, just press the
PROG/OK
button. Then
the current value is not changed.
• After you have changed the last of the three setting options re-
spectively confirmed them by pressing PROG/OK, nothing will
flash. You are now back in the display mode of the panel and can
now either make changes to other setting options of the panel
by pressing PROG/OK again or select another panel with the (+)
and (-) buttons.
For a list of all possible panels and their setting options, see Chap-
ter 15.
6.3. Address mode for ROCO® command stations
As already mentioned in Chapter 6.1, ROCO® command stations
(specially the multiMaus, but also the Z21 in the standard setting)
use a different computation method to calculate the turnout num-
bers from the accessory addresses. Set the decoder to “ROCO” to
ensure that the SwitchPilot 3 handles instructions from ROCO®
command stations correctly.
To do this, select „Mode” in the „ADDRESS MODE” panel, and
then select the calculation method „ROCO”.
Introduction to the operating structure
6.4. Configuring outputs
Each output can be configured individually. For this purpose, the
panels „OUTPUT 1” to „OUTPUT 4” are provided.
You can use the “Mode” option to set the desired output mode:
• “Pulse” configures pulse operation according to chapter 4.4.1.
• “PECO” configures PECO operating mode according to chapter
4.4.2.
• “K83” configures momentary action mode according to chapter
4.4.3.
•
“K84” configures bistable continuous operation according to
chapter 4.4.4.
• “Alt Flash” configures the alternating flasher operation according
to chapter 4.4.5.
The meaning of the „Time” option depends on the selected out-
put mode:
• In pulse mode, it is determined here how long the output remains
switched on.
• In alternating flasher mode, you specify how fast the two outputs
should flash.
• In all other modes, „Time” has no meaning and cannot be chan-
ged respectively is set to „Permanent”.
OUTPUT1
Mode : Impulse
Time : 520 ms
Zoom : Disabled
OUTPUT2
Mode : PECO
Time : Permanent
Zoom : Disabled
OUTPUT3
Mode : K83
Time : Permanent
Zoom : Disabled
OUTPUT4
Mode : Alt-Flash
Time : 1170ms
Zoom : Enabled