12
SINGLE
: DestPosX
Unit: mm
X = 100.50
Y = 120.05
XP =
55.00
YP =
0.00
DX =
20.00
HT =
2.00
DLY= 2.00
PP =
150
CP =
100
OPN=
0.00
XP =
55.00
Figure 3-2
The
SINGLE
page
The description of the
SINGLE
parameters is as shown in Table 3-1.
Table 3-1
The description of the
SINGLE
parameters
Parameter
Default
Range
Unit
Description
XP
0.00
0~9999.999
mm/inch
Program position of X axle.
YP
0.00
0~9999.999
mm/inch
Program position of Y axle.
DX
0.00
0~9999.999
mm/inch
Retract distance of X axle.
HT
0.00
0~99.99
s
The interval time from
LDP
signal to
decompression process.
DLY
0.00
0~99.99
s
In case of single step, delay time for
X-axle retracting.
PP
0
0~9999
-
The number of processing workpiece
in this program.
CP
0
0~9999
-
PP=0: this value is the current
work piece.
PP>0: this value is the remain
work piece.
OPN
0.00
0~999.999
mm/inch
After bending, the distance of the
Y-axis opening.